VALVE CONTROL WIRE - PROVIDE
<br />3M DBY SEAL PACKS AT ALL SPLICES
<br />AND 36" OF EXCESS OF WIRE IN A
<br />1" DIAMETER COIL.
<br />RECTANGULAR PLASTIC VALVE BOX
<br />WITH BOLT DOWN LID. ONE VALVE PER
<br />BOX - NO EXCEPTIONS. INSTALL BOX AS
<br />SHOWN IN BOX INSTALLATION DETAIL.
<br />TOP DIMENSION: 11 314"x 17"
<br />(12" DEEP).
<br />REMOTE CONTROL
<br />VALVE WITH FLOW CONTROL illi
<br />AND MANUAL BLEED
<br />SCHEDULE 80 PVC
<br />THREADED FITTINGS
<br />(AS REQUIRED) I
<br />PVC MAIN LINE
<br />FINISH GRADE
<br />I.
<br />PEA GRAVEL - 4"
<br />DEEP BELOW VALVE
<br />(NO SOIL IN VALVE BOX)
<br />BRICK - 1 EACH
<br />CORNER
<br />- UPC APPROVED PVC MAIN LINE - CAP AND
<br />CLASS 200 PVC THRUST BLOCK IF AT END
<br />O-RING SERVICE OF LINE.
<br />TEE
<br />REMOTE CONTROL VALVE DETAIL
<br />SCHEDULE 40
<br />PVC MALE
<br />ADAPTER
<br />PVC LATERAL
<br />LINE
<br />LOWER LATERAL
<br />LINE WITH SCH.
<br />40 PVC 45°
<br />ELBOWS
<br />REFER TO
<br />IRRIGATION
<br />LEGEND
<br />i I
<br />IRRIGATION NOTES
<br />1. THESE IRRIGATION DRAWINGS ARE DIAGRAMMATIC AND INDICATIVE
<br />OF THE WORK TO BE INSTALLED. ALL PIPING, VALVES, ETC. SHOWN
<br />WITHIN PAVED AREAS IS FOR CLARITY ONLY AND ARE TO BE
<br />INSTALLED WITHIN PLANTING AREAS WHERE POSSIBLE. DUE TO THE
<br />SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL
<br />OFFSETS, FITTINGS, SLEEVES, ETC. WHICH MAY BE REQUIRED. THE
<br />CONTRACTOR IS REQUIRED TO INVESTIGATE THE STRUCTURAL AND
<br />FINISHED CONDITIONS AFFECTING ALL OF THE CONTRACT WORK
<br />INCLUDING OBSTRUCTIONS, GRADE DIFFERENCES OR AREA
<br />DIMENSIONAL DIFFERENCES WHICH MAY NOT HAVE BEEN
<br />CONSIDERED IN THE ENGINEERING. IN THE EVENT OF FIELD
<br />DIFFERENCES, THE CONTRACTOR IS REQUIRED TO PLAN THE
<br />INSTALLATION WORK ACCORDINGLY BY NOTIFICATION AND
<br />APPROVAL OF THE OWNER'S AUTHORIZED REPRESENTATIVE AND
<br />ACCORDING TO THE CONTRACT SPECIFICATIONS. THE
<br />CONTRACTOR IS ALSO REQUIRED TO NOTIFY AND COORDINATE
<br />IRRIGATION CONTRACT WORK WITH ALL APPLICABLE CONTRACTORS
<br />FOR THE LOCATION AND INSTALLATION OF PIPE, CONDUIT OR
<br />SLEEVES THROUGH OR UNDER WALLS, ROADWAYS, PAVING,
<br />STRUCTURE, ETC. BEFORE CONSTRUCTION. IN THE EVENT THESE
<br />NOTIFICATIONS ARE NOT PERFORMED, THE CONTRACTOR SHALL
<br />ASSUME FULL RESPONSIBILITY FOR ALL REQUIRED REVISIONS.
<br />2. THE INTENT OF THIS IRRIGATION SYSTEM IS TO PROVIDE THE
<br />MINIMUM AMOUNT OF WATER REQUIRED TO SUSTAIN GOOD PLANT
<br />HEALTH.-
<br />3.
<br />EALTH.-3. IT IS THE RESPONSIBILITY OF THE LANDSCAPE MAINTENANCE
<br />CONTRACTOR AND/OR OWNER TO PROGRAM THE IRRIGATION
<br />CONTROLLERS TO PROVIDE THE MINIMUM AMOUNT OF WATER
<br />NEEDED TO SUSTAIN GOOD PLANT HEALTH. THIS INCLUDES MAKING
<br />ADJUSTMENTS TO THE PROGRAM FOR SEASONAL WEATHER
<br />CHANGES, PLANT MATERIAL, WATER REQUIREMENTS, MOUNDS AND
<br />SLOPES, SUN, SHADE AND WIND EXPOSURES.
<br />4. 120 VOLT A.C. (2.5 AMP DEMAND PER CONTROLLER) ELECTRICAL
<br />SERVICE TO IRRIGATION CONTROLLER LOCATIONS TO BE PROVIDED
<br />UNDER ELECTRICAL CONTRACT WORK. IRRIGATION CONTRACTOR
<br />TO MAKE FINAL CONNECTION FROM ELECTRICAL STUB -OUT TO
<br />CONTROLLERS AND PROVIDE PROPER GROUNDING PER
<br />CONTROLLER MANUFACTURER'S INSTRUCTIONS.
<br />TSI STRONG BOX COLD ROLLED
<br />STEEL CONTROLLER ENCLOSURE ENCLOSURE
<br />MODEL IISB-18 CR. DOOR
<br />19�
<br />CONTROLLER TO BE MOUNTED ON
<br />MOUNTING PANEL OF ENCLOSURE
<br />000 1
<br />TSI STRONG BOX CONTROLLER p°O
<br />SUBASSEMBLY#CSA
<br />#10 BARE COPPER - - - -1
<br />36' GROUND WIRE I I 2
<br />STEEL BASE WITH MOUNTING
<br />STUDS INCLUDED WITH I
<br />ENCLOSURE I I ROUND PLASTIC VALVE BOX
<br />I WITH BOLT DOWN LID.
<br />L_ e _ J
<br />O TOP DIMENSION: 10". FINISH GRADE
<br />FINISH GRADE -
<br />�IIII '. • .. • Ilj�_ =III ' L= 18. L 3.
<br />�• . • ,. : = 1' _ i II PEA GRAVEL
<br />6' THICK CONCRETE SLAB TO 3 4 5 BRICK- 2 TOTAL
<br />EXTEND 6' BEYOND THREE SIDES LOW VOLTAGE CONTROL
<br />OF ENCLOSURE AND 12' BEYOND WIRES (EXTEND CONDUIT REFER TO IRRIGATION
<br />FRONT. 12' BEYOND CONCRETE
<br />LEGEND
<br />120 VOLT A.C. ELECTRICAL SERVICE FROM SOURCE TO CONTROLLER SLAB) a� GATE VALVE WITH 2"
<br />LOCATION PROVIDE BY ELECTRICAL CONTRACTOR. IRRIGATION SCHEDULE 40 GREY OPERATING NUT
<br />CONTRACTOR TO PROVIDE RIGID STEEL CONDUIT FROM SERVICE PVC ELECTRICAL (O RING CONNECTION)
<br />STUB -OUT TO CONTROLLER GCFI SWITCH AND COMPLETE
<br />ELECTRICAL SERVICE TO CONTROLLER. CONDUIT WITH SWEEP O- RING PVC 8" CLASS 160 OR SCHEDULE 40
<br />ELL FOR LOW VOLTAGE OOOODUU MAIN LINE PVC PIPE (NOTCH TO FIT OVER
<br />WIRE PROVIDED UNDER MAJN LINE PIPE)
<br />SIDE VIEW FRONT VIEW
<br />IRRIGATION CONTRACT. INSTRUCTIONS:
<br />8' GROUNOtNG ROD 1. STRIP WIRES APPROXIMATELY 1/2" (12.7 MM) TO EXPOSE WIRE.
<br />(INSIDE ENCLOSURE) 2. TWIST CONNECTOR AROUND WIRES CLOCKWISE UNTIL HAND TIGHT, DO NOT OVERTIGHTEN. >IS
<br />3. INSERT WIRE ASSEMBLY INTO PLASTIC TUBE UNTIL WIRE CONNECTOR SNAPS PAST LIP IN #4 REBAR BEND OVER �, CONCRETE THRUST BLOCK
<br />BOTTOM OF TUBE. 4 ' �
<br />4. PLACE WIRES WHICH EXIT TUBE IN WIRE EXIT HOLES AND CLOSE CAP UNTIL IT SNAPS. VALVE BODY
<br />5. INSPECT FINAL SPLICE ASSEMBLY TO BE SECURE AND FINISHED.
<br />CONTROLLER IN 4T WEATHERPROOF SPLICE ASSEMBLY DETAIL 3' ENCLOSURE DETAIL 1 AND LARGER
<br />GATE VALVE DETAIL
<br />SEE LEGEND FOR
<br />MAIN LINE DEPTH
<br />-6.. � r --CURB OR WALK
<br />wtUnl VARIES -
<br />COMMON TRENCH DETAIL
<br />lU' LATERAL LINE
<br />o�
<br />-2"
<br />-- - 3" NI:I.
<br />CONTROL WIR[�
<br />R11N LINE
<br />NOTE* NIPPLES AND FITTINGS TO BE SAME SIZE
<br />DIAIIETER OF ,-CURB OR WALK AS VALVE IPT INLET THREAD SIZE.
<br />PIPE PLUS 4 f_ QUICK COUPLING VALVE
<br />(SET AT FINISH GRADE IN
<br />fl�j= SINGLE LINE TRENCH DETAIL 12" TURF AREAS - WHERE
<br />APPLICABLE)
<br />FINISH GRADE ROUND PLASTIC VALVE BOX WITH
<br />'•'. 1" BOLT DOWN LID. TOP DIMENSION: 10".
<br />LLATERAL LINE-12"IIlI FINISH GRADE
<br />WALL, WALK,
<br />hV1IN LINE- SEE LEGEND CURB OR HEADER
<br />REFER TO IRRIGATION SCHEDULE 80 PVC=11 g
<br />CONTROL WIRE -18" LE END THREADED NIPPLE :5 3"
<br />4 AT CONDUIT -
<br />10" LONG SCHEDULE 80 II)] PEA GRAVEL
<br />6" AT SLEEVING - -REPLACE TO MATCH EXISTING PAVING PVC THREADED NIPPLE
<br />{-EXISTING A.C. PAVING
<br />L11- 111/1 REFER TO IRRIGATION
<br />BRICK 2 TOTAL
<br />_ BACKFILL TO BE LEGEND
<br />24 IIIA COMPACTED TO 95% SIDE VIEW
<br />TRENCHING UNDER PAVING PVC MAIN LINE UPC APPROVED SCHEDULE
<br />40 PVC TEE OR ELBOW °
<br />GATE VALVE
<br />•
<br />8" CLASS 160 OR SCHEDULE 40 PVC
<br />CONDUIT FOR CONTROL WIRE OR 3" LONG SCHEDULE 80 PIPE (NOTCH TO FIT OVER MAIN
<br />LINE PIPE)
<br />SLEEYIi1G FOR MAIN AND/OR LATERAL LINES
<br />PVC THREADED NIPPLE
<br />i. IF THE EXCAVATED NATIVE MATERIAL IS LARGER THAN 3/4" DIA., IT SHALL BE THE RESPONSIBILITY
<br />OF THE GENERAL CONTRACTOR TO PROVIDE THE SUITABLE BACKFILL I•IATERIAL. THE SUITABILITY OF LL -A
<br />THE BACKFILL MATERIAL SHALL BE DETERIII14ED AT THE CITY'S DISCRETION. THE AFOREMENTIONED SCHEDULE 80 PVC
<br />14ATERIAL SHALL BE COMPACTED TO 90% RELATIVE COMPACTION. BACKFILL MATERIAL SHALL BE THREADED 900 ELL CLASS 200 PVC
<br />EXCAVATED NATIVE 14ATERIAL THAT IS CLEAR OF ALL DEBRIS AND ROCKS LARGER THAN 1/4" IN
<br />MALE x BELL ADAPTER
<br />DIAMETER.
<br />2. PROVIDE 24" SEPARATION BETWEEN IRRIGATION LILIES AND VARIOUS UTILITIES. TOP VIEW PVC MAIN LINE
<br />TRENCHING DETAIL 5 QUICK COUPLING VALVE DETAIL 2 2 1/2SMALLER
<br />GATE VALVE DETAIL
<br />5. EACH CONTROLLER SHALL HAVE ITS OWN GROUND ROD. SEPARATE
<br />THE GROUND RODS BY A MINIMUM OF EIGHT FEET. THE GROUND
<br />ROD SHALL BE AN EIGHT FOOT LONG BY 5/8" DIAMETER U.L.
<br />APPROVED COPPER CLAD ROD. NO MORE THAN 6" OF THE GROUND
<br />ROD TO BE ABOVE GRADE. CONNECT #8 GAUGE WIRE WITH A U.L.
<br />APPROVED GROUND ROD CLAMP TO ROD AND BACK TO GROUND
<br />SCREW AT BASE OF CONTROLLER WITH APPROPRIATE CONNECTOR.
<br />THIS WIRE SHOULD BE AS SHORT AS POSSIBLE, AVOIDING ANY KINKS
<br />OR BENDING.
<br />6. EACH IRRIGATION CONTROLLER TO HAVE ITS OWN- INDEPENDENT 24
<br />VOLT COMMON GROUND WIRE.
<br />7. IRRIGATION CONTROL WIRES SHALL BE COPPER WITH U.L. APPROVAL
<br />FOR DIRECT BURIAL IN GROUND, SIZE #14-1. COMMON GROUND
<br />WIRE SHALL HAVE WHITE INSULATING JACKET. CONTROL WIRE
<br />SHALL HAVE INSULATING JACKET OF COLOR OTHER THAN WHITE.
<br />SPLICE SHALL BE MADE WITH 3M-DBY SEAL PACKS.
<br />8. INSTALL SPARE CONTROL WIRE OF A DIFFERENT COLOR ALONG THE
<br />ENTIRE MAIN LINE. LOOP 36" EXCESS WIRE INTO EACH SINGLE VALVE
<br />BOX AND INTO ONE VALVE BOX IN EACH GROUP OF VALVES.
<br />9. SPLICING OF 24 VOLT WIRES IS NOT PERMITTED EXCEPT IN VALVE
<br />BOXES. LEAVE A 36" LONG, 1" DIAMETER COIL OF EXCESS WIRE AT
<br />EACH SPLICE AND A 36" LONG EXPANSION LOOP EVERY 100 FEET
<br />ALONG WIRE RUN. TAPE WIRES TOGETHER EVERY TEN FEET. TAPING
<br />WIRES IS NOT REQUIRED INSIDE SLEEVES.
<br />10. PLASTIC VALVE BOXES ARE TO BE GREEN IN COLOR WITH BOLT
<br />DOWN, NON -HINGED COVER MARKED "IRRIGATION". BOX BODY SHALL
<br />HAVE KNOCK OUTS. MANUFACTURER SHALL BE BROOKS OR CARSON.
<br />11. INSTALL REMOTE CONTROL VALVE BOXES 12" FROM WALK, CURB,
<br />LAWN, HEADER BOARD, BUILDING, OR LANDSCAPE FEATURE. AT
<br />MULTIPLE VALVE BOX GROUPS, EACH BOX SHALL BE AN EQUAL
<br />DISTANCE FROM THE WALK, CURB, LAWN, ETC. AND EACH BOX SHALL
<br />BE 12" APART. SHORT SIDE OF RECTANGULAR VALVE BOXES SHALL
<br />BE PARALLEL TO WALK, CURB, LAWN, ETC.
<br />12. FOR 2 1/2" AND LARGER MAIN LINE PIPING INSIDE SLEEVES USE 1120-
<br />315 PSI PVC PLASTIC PIPE WITH SCHEDULE 40 PVC COUPLINGS. NO
<br />RING-TITE COUPLINGS INSIDE SLEEVES.
<br />13. THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL
<br />SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO PREVENT
<br />OVER SPRAY ONTO WALKS, ROADWAYS, AND/OR BUILDINGS AS MUCH
<br />AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST DEGREE
<br />OF ARC TO FIT THE EXISTING SITE CONDITIONS AND TO THROTTLE
<br />THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM
<br />OPERATING PRESSURE FOR EACH SYSTEM.
<br />14. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH
<br />GRADE OF THE AREA TO BE IRRIGATED UNLESS OTHERWISE NOTED
<br />ON THE DRAWINGS.
<br />15. LOCATE BUBBLERS ON UP -HILL SIDE OF PLANT OR TREE.
<br />16. AT LOCATIONS WHERE LOW SPRINKLER HEAD DRAINAGE WILL CAUSE
<br />EROSION AND/OR EXCESS WATER, USE A RAIN BIRD 1800 -SAM SERIES
<br />POP-UP BODY WITH INTEGRAL CHECK VALVE AND A VALCON 5000
<br />SERIES SPRING LOADED CHECK VALVE ON SHRUB RISERS IN LIEU OF
<br />SCHEDULE 80 COUPLING.
<br />17. WHERE IT IS NECESSARY TO EXCAVATE ADJACENT TO EXISTING
<br />TREES, THE CONTRACTOR SHALL USE ALL POSSIBLE CARE TO AVOID
<br />INJURY TO TREES AND TREE ROOTS. EXCAVATION IN AREAS WHERE
<br />TWO (2) INCH AND LARGER ROOTS OCCUR SHALL BE DONE BY HAND.
<br />ROOTS ONE (1) INCH AND LARGER IN DIAMETER SHALL BE PAINTED
<br />WITH TWO COATS OF TREE SEAL, OR EQUAL. TRENCHES ADJACENT
<br />TO TREE SHOULD BE CLOSED WITHIN TWENTY-FOUR (24) HOURS;
<br />AND INHERE THIS IS NOT POSSIBLE, THE SIDE OF THE TRENCH
<br />ADJACENT TO THE TREE SHALL BE KEPT SHADED WITH BURLAP OR
<br />CANVAS.
<br />18. IRRIGATION CONTRACTOR TO NOTIFY ALL LOCAL JURISDICTIONS
<br />FOR INSPECTION AND TESTING OF INSTALLED BACKFLOW
<br />PREVENTION DEVICE.
<br />19. THE SPRINKLER SYSTEM DESIGN IS BASED ON THE MINIMUM
<br />OPERATING PRESSURE SHOWN ON THE IRRIGATION DRAWINGS. THE
<br />IRRIGATION CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR
<br />TO CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE
<br />WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL
<br />PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO
<br />THE OWNER'S AUTHORIZED REPRESENTATIVE.
<br />20. IRRIGATION DEMAND: ISo GPM AT 60 PSI STATIC PRESSURE AT
<br />IRRIGATION POINT OF CONNECTION.
<br />21. THE EXISTING MAIN LINE SHOWN ON THE DRAWINGS IS
<br />DIAGRAMMATIC. CONTRACTOR TO VERIFY AND LOCATE EXISTING
<br />MAIN LINE IN FIELD. ANY DEVIATION OF EXISTING MAIN LINE
<br />LOCATION AS SHOWN ON THE DRAWINGS IS TO BE REPORTED TO
<br />ARCHITECT FOR REVIEW AND POSSIBLE REVISION.
<br />22. COLOR CODE WIRES FOR EASE OF IDENTIFICATION BY PROVIDING A
<br />DIFFERENT COLOR CONTROL WIRE FOR ADJACENT CONTROLLERS.
<br />23. PIPE THREAD SEALANT COMPOUND SHALL BE LASCO #905-305,
<br />PERMATEX 51 OR RECTOR SEAL T+2.
<br />24. THE CONTRACTOR SHALL EXERCISE CARE WHEN WORKING IN AREAS
<br />ADJACENT TO EXISTING PLANTING AND IRRIGATION TO REMAIN.
<br />EXISTING TREES, SHRUBS, LAWNS AND OTHER PLANT MATERIALS TO
<br />REMAIN SHALL BE PROTECTED AT ALL TIMES. IRRIGATION LINES
<br />SERVICING EXISTING PLANTING AREAS TO REMAIN SHALL BE CUT
<br />AND TEMPORARILY CAPPED DURING DEMOLITION AND RESTORED TO
<br />FULL OPERATION UNDER THIS CONTRACT UNLESS SPECIFICALLY
<br />NOTED ON THE PLANS AS BEING OTHERWISE. CONTRACTOR SHALL
<br />PROVIDE TEMPORARY IRRIGATION IN THESE AREAS UNTIL
<br />IRRIGATION CAN BE FULLY RESTORED. EXISTING PLANT MATERIALS
<br />SHALL BE MAINTAINED IN A HEALTHY CONDITION UNLESS
<br />OTHERWISE NOTED ON THE PLANS AS BEING REMOVED OR
<br />REPLACED. SAN JOAQUIN
<br />GENERAL HOSPITAL
<br />REPLACEMENT PROJECT,
<br />PHASE 1A
<br />IRRIGATION DETAILS
<br />& NOTES
<br />Irrigation Consultant: Scale: NONE
<br />Russell D. Mitchell & Assoclates, Inc.
<br />2760 Camino Diablo
<br />Stone
<br />Marrabcini
<br />Patterson
<br />Architecture
<br />Planning
<br />Interior Architecture
<br />One Market Plaza
<br />Spear Street Tower
<br />Suite 400
<br />San Francisco
<br />CA 94105
<br />415 227-0100
<br />Architect,AIA
<br />Tech. Checked Tech.
<br />Coord. Arch.
<br />RUTHERFORD & CHEKENE
<br />303 Second St. Suite 800 N.
<br />San Francisco, CA 94107
<br />Structural Engineer
<br />GUTMANN & MacRITCHIE
<br />1304 Sutter Street
<br />Son Francisco, CA 94109
<br />Mechanical Engineer
<br />THE ENGINEERING ENTERPRISE
<br />1305 Marino Village Parkway
<br />Alameda, CA 94501
<br />Electrical Engineer
<br />MPA DESIGN
<br />562 Mission Street
<br />San Francisco, CA 94105
<br />Landscape Architect
<br />Approvals
<br />Revisions
<br />90c;� RI:VIEW
<br />Date
<br />23 M2\11Z ()2
<br />Walnut Creek, CA 94596 Project No. Drawing N o_
<br />(510) 939-3985
<br />(510) 932-5671 FAX 53000.09
<br />Date
<br />L4nC0
<br />NOTES: 1. NIPPLES AND FITTINGS TO BE SAME IPT SIZE AS
<br />BACKFLOW ASSEMBLY.
<br />2. DO NOT SOLDER CONNECT FITTINGS WHILE THREADED
<br />INTO BACKFLOW ASSEMBLY. DAMAGE MAY OCCUR.
<br />REDUCED PRESSURE
<br />BACKFLOW ASSEMBLY
<br />FLOW
<br />BRASS CLOSE THREADED
<br />NIPPLE (4 TOTAL)
<br />BRASS 90' ELBOW- 2 TOTAL
<br />BRASS UNION- 2 TOTAL
<br />(FIPT CONNECTION)
<br />(FIPT CONNECTION)
<br />I ( I I
<br />WROT COPPER MALE
<br />ADAPTER- 2 TOTAL
<br />-
<br />(SOLDER x THREAD
<br />CONNECTION)
<br />-
<br />COPPER TYPE "K"
<br />12" -
<br />PIPE (LENGTH AS
<br />FINISH GRADE
<br />REQUIRED)
<br />II�
<br />III
<br />WROT COPPER 900
<br />-
<br />REFER TO IRRIGATION
<br />ELBOW- 2 TOTAL (SOLDER
<br />LEGEND
<br />x THREAD CONNECTION)
<br />o
<br />PVC MAIN LINE
<br />BUSH AS NECESSARY CONCRETE SUPPORT
<br />PVC MAIN LINE TO
<br />TO POINT OF
<br />FOR SIZE TRANSITION BLOCK
<br />IRRIGATION SYSTEM
<br />CONNECTION
<br />CLASS 200 PVC O-RING x
<br />MIPT MALE ADAPTER
<br />2" -AND
<br />6
<br />SMALLER REDUCED PRESSURE
<br />3
<br />BACKFLOW ASSEMBLY
<br />VALVE CONTROL WIRE - PROVIDE
<br />3M DBY SEAL PACKS AT ALL SPLICES
<br />AND 36" OF EXCESS OF WIRE IN A
<br />1" DIAMETER COIL.
<br />RECTANGULAR PLASTIC VALVE BOX
<br />WITH BOLT DOWN LID. ONE VALVE PER
<br />BOX - NO EXCEPTIONS. INSTALL BOX AS
<br />SHOWN IN BOX INSTALLATION DETAIL.
<br />TOP DIMENSION: 11 314"x 17"
<br />(12" DEEP).
<br />REMOTE CONTROL
<br />VALVE WITH FLOW CONTROL illi
<br />AND MANUAL BLEED
<br />SCHEDULE 80 PVC
<br />THREADED FITTINGS
<br />(AS REQUIRED) I
<br />PVC MAIN LINE
<br />FINISH GRADE
<br />I.
<br />PEA GRAVEL - 4"
<br />DEEP BELOW VALVE
<br />(NO SOIL IN VALVE BOX)
<br />BRICK - 1 EACH
<br />CORNER
<br />- UPC APPROVED PVC MAIN LINE - CAP AND
<br />CLASS 200 PVC THRUST BLOCK IF AT END
<br />O-RING SERVICE OF LINE.
<br />TEE
<br />REMOTE CONTROL VALVE DETAIL
<br />SCHEDULE 40
<br />PVC MALE
<br />ADAPTER
<br />PVC LATERAL
<br />LINE
<br />LOWER LATERAL
<br />LINE WITH SCH.
<br />40 PVC 45°
<br />ELBOWS
<br />REFER TO
<br />IRRIGATION
<br />LEGEND
<br />i I
<br />IRRIGATION NOTES
<br />1. THESE IRRIGATION DRAWINGS ARE DIAGRAMMATIC AND INDICATIVE
<br />OF THE WORK TO BE INSTALLED. ALL PIPING, VALVES, ETC. SHOWN
<br />WITHIN PAVED AREAS IS FOR CLARITY ONLY AND ARE TO BE
<br />INSTALLED WITHIN PLANTING AREAS WHERE POSSIBLE. DUE TO THE
<br />SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL
<br />OFFSETS, FITTINGS, SLEEVES, ETC. WHICH MAY BE REQUIRED. THE
<br />CONTRACTOR IS REQUIRED TO INVESTIGATE THE STRUCTURAL AND
<br />FINISHED CONDITIONS AFFECTING ALL OF THE CONTRACT WORK
<br />INCLUDING OBSTRUCTIONS, GRADE DIFFERENCES OR AREA
<br />DIMENSIONAL DIFFERENCES WHICH MAY NOT HAVE BEEN
<br />CONSIDERED IN THE ENGINEERING. IN THE EVENT OF FIELD
<br />DIFFERENCES, THE CONTRACTOR IS REQUIRED TO PLAN THE
<br />INSTALLATION WORK ACCORDINGLY BY NOTIFICATION AND
<br />APPROVAL OF THE OWNER'S AUTHORIZED REPRESENTATIVE AND
<br />ACCORDING TO THE CONTRACT SPECIFICATIONS. THE
<br />CONTRACTOR IS ALSO REQUIRED TO NOTIFY AND COORDINATE
<br />IRRIGATION CONTRACT WORK WITH ALL APPLICABLE CONTRACTORS
<br />FOR THE LOCATION AND INSTALLATION OF PIPE, CONDUIT OR
<br />SLEEVES THROUGH OR UNDER WALLS, ROADWAYS, PAVING,
<br />STRUCTURE, ETC. BEFORE CONSTRUCTION. IN THE EVENT THESE
<br />NOTIFICATIONS ARE NOT PERFORMED, THE CONTRACTOR SHALL
<br />ASSUME FULL RESPONSIBILITY FOR ALL REQUIRED REVISIONS.
<br />2. THE INTENT OF THIS IRRIGATION SYSTEM IS TO PROVIDE THE
<br />MINIMUM AMOUNT OF WATER REQUIRED TO SUSTAIN GOOD PLANT
<br />HEALTH.-
<br />3.
<br />EALTH.-3. IT IS THE RESPONSIBILITY OF THE LANDSCAPE MAINTENANCE
<br />CONTRACTOR AND/OR OWNER TO PROGRAM THE IRRIGATION
<br />CONTROLLERS TO PROVIDE THE MINIMUM AMOUNT OF WATER
<br />NEEDED TO SUSTAIN GOOD PLANT HEALTH. THIS INCLUDES MAKING
<br />ADJUSTMENTS TO THE PROGRAM FOR SEASONAL WEATHER
<br />CHANGES, PLANT MATERIAL, WATER REQUIREMENTS, MOUNDS AND
<br />SLOPES, SUN, SHADE AND WIND EXPOSURES.
<br />4. 120 VOLT A.C. (2.5 AMP DEMAND PER CONTROLLER) ELECTRICAL
<br />SERVICE TO IRRIGATION CONTROLLER LOCATIONS TO BE PROVIDED
<br />UNDER ELECTRICAL CONTRACT WORK. IRRIGATION CONTRACTOR
<br />TO MAKE FINAL CONNECTION FROM ELECTRICAL STUB -OUT TO
<br />CONTROLLERS AND PROVIDE PROPER GROUNDING PER
<br />CONTROLLER MANUFACTURER'S INSTRUCTIONS.
<br />TSI STRONG BOX COLD ROLLED
<br />STEEL CONTROLLER ENCLOSURE ENCLOSURE
<br />MODEL IISB-18 CR. DOOR
<br />19�
<br />CONTROLLER TO BE MOUNTED ON
<br />MOUNTING PANEL OF ENCLOSURE
<br />000 1
<br />TSI STRONG BOX CONTROLLER p°O
<br />SUBASSEMBLY#CSA
<br />#10 BARE COPPER - - - -1
<br />36' GROUND WIRE I I 2
<br />STEEL BASE WITH MOUNTING
<br />STUDS INCLUDED WITH I
<br />ENCLOSURE I I ROUND PLASTIC VALVE BOX
<br />I WITH BOLT DOWN LID.
<br />L_ e _ J
<br />O TOP DIMENSION: 10". FINISH GRADE
<br />FINISH GRADE -
<br />�IIII '. • .. • Ilj�_ =III ' L= 18. L 3.
<br />�• . • ,. : = 1' _ i II PEA GRAVEL
<br />6' THICK CONCRETE SLAB TO 3 4 5 BRICK- 2 TOTAL
<br />EXTEND 6' BEYOND THREE SIDES LOW VOLTAGE CONTROL
<br />OF ENCLOSURE AND 12' BEYOND WIRES (EXTEND CONDUIT REFER TO IRRIGATION
<br />FRONT. 12' BEYOND CONCRETE
<br />LEGEND
<br />120 VOLT A.C. ELECTRICAL SERVICE FROM SOURCE TO CONTROLLER SLAB) a� GATE VALVE WITH 2"
<br />LOCATION PROVIDE BY ELECTRICAL CONTRACTOR. IRRIGATION SCHEDULE 40 GREY OPERATING NUT
<br />CONTRACTOR TO PROVIDE RIGID STEEL CONDUIT FROM SERVICE PVC ELECTRICAL (O RING CONNECTION)
<br />STUB -OUT TO CONTROLLER GCFI SWITCH AND COMPLETE
<br />ELECTRICAL SERVICE TO CONTROLLER. CONDUIT WITH SWEEP O- RING PVC 8" CLASS 160 OR SCHEDULE 40
<br />ELL FOR LOW VOLTAGE OOOODUU MAIN LINE PVC PIPE (NOTCH TO FIT OVER
<br />WIRE PROVIDED UNDER MAJN LINE PIPE)
<br />SIDE VIEW FRONT VIEW
<br />IRRIGATION CONTRACT. INSTRUCTIONS:
<br />8' GROUNOtNG ROD 1. STRIP WIRES APPROXIMATELY 1/2" (12.7 MM) TO EXPOSE WIRE.
<br />(INSIDE ENCLOSURE) 2. TWIST CONNECTOR AROUND WIRES CLOCKWISE UNTIL HAND TIGHT, DO NOT OVERTIGHTEN. >IS
<br />3. INSERT WIRE ASSEMBLY INTO PLASTIC TUBE UNTIL WIRE CONNECTOR SNAPS PAST LIP IN #4 REBAR BEND OVER �, CONCRETE THRUST BLOCK
<br />BOTTOM OF TUBE. 4 ' �
<br />4. PLACE WIRES WHICH EXIT TUBE IN WIRE EXIT HOLES AND CLOSE CAP UNTIL IT SNAPS. VALVE BODY
<br />5. INSPECT FINAL SPLICE ASSEMBLY TO BE SECURE AND FINISHED.
<br />CONTROLLER IN 4T WEATHERPROOF SPLICE ASSEMBLY DETAIL 3' ENCLOSURE DETAIL 1 AND LARGER
<br />GATE VALVE DETAIL
<br />SEE LEGEND FOR
<br />MAIN LINE DEPTH
<br />-6.. � r --CURB OR WALK
<br />wtUnl VARIES -
<br />COMMON TRENCH DETAIL
<br />lU' LATERAL LINE
<br />o�
<br />-2"
<br />-- - 3" NI:I.
<br />CONTROL WIR[�
<br />R11N LINE
<br />NOTE* NIPPLES AND FITTINGS TO BE SAME SIZE
<br />DIAIIETER OF ,-CURB OR WALK AS VALVE IPT INLET THREAD SIZE.
<br />PIPE PLUS 4 f_ QUICK COUPLING VALVE
<br />(SET AT FINISH GRADE IN
<br />fl�j= SINGLE LINE TRENCH DETAIL 12" TURF AREAS - WHERE
<br />APPLICABLE)
<br />FINISH GRADE ROUND PLASTIC VALVE BOX WITH
<br />'•'. 1" BOLT DOWN LID. TOP DIMENSION: 10".
<br />LLATERAL LINE-12"IIlI FINISH GRADE
<br />WALL, WALK,
<br />hV1IN LINE- SEE LEGEND CURB OR HEADER
<br />REFER TO IRRIGATION SCHEDULE 80 PVC=11 g
<br />CONTROL WIRE -18" LE END THREADED NIPPLE :5 3"
<br />4 AT CONDUIT -
<br />10" LONG SCHEDULE 80 II)] PEA GRAVEL
<br />6" AT SLEEVING - -REPLACE TO MATCH EXISTING PAVING PVC THREADED NIPPLE
<br />{-EXISTING A.C. PAVING
<br />L11- 111/1 REFER TO IRRIGATION
<br />BRICK 2 TOTAL
<br />_ BACKFILL TO BE LEGEND
<br />24 IIIA COMPACTED TO 95% SIDE VIEW
<br />TRENCHING UNDER PAVING PVC MAIN LINE UPC APPROVED SCHEDULE
<br />40 PVC TEE OR ELBOW °
<br />GATE VALVE
<br />•
<br />8" CLASS 160 OR SCHEDULE 40 PVC
<br />CONDUIT FOR CONTROL WIRE OR 3" LONG SCHEDULE 80 PIPE (NOTCH TO FIT OVER MAIN
<br />LINE PIPE)
<br />SLEEYIi1G FOR MAIN AND/OR LATERAL LINES
<br />PVC THREADED NIPPLE
<br />i. IF THE EXCAVATED NATIVE MATERIAL IS LARGER THAN 3/4" DIA., IT SHALL BE THE RESPONSIBILITY
<br />OF THE GENERAL CONTRACTOR TO PROVIDE THE SUITABLE BACKFILL I•IATERIAL. THE SUITABILITY OF LL -A
<br />THE BACKFILL MATERIAL SHALL BE DETERIII14ED AT THE CITY'S DISCRETION. THE AFOREMENTIONED SCHEDULE 80 PVC
<br />14ATERIAL SHALL BE COMPACTED TO 90% RELATIVE COMPACTION. BACKFILL MATERIAL SHALL BE THREADED 900 ELL CLASS 200 PVC
<br />EXCAVATED NATIVE 14ATERIAL THAT IS CLEAR OF ALL DEBRIS AND ROCKS LARGER THAN 1/4" IN
<br />MALE x BELL ADAPTER
<br />DIAMETER.
<br />2. PROVIDE 24" SEPARATION BETWEEN IRRIGATION LILIES AND VARIOUS UTILITIES. TOP VIEW PVC MAIN LINE
<br />TRENCHING DETAIL 5 QUICK COUPLING VALVE DETAIL 2 2 1/2SMALLER
<br />GATE VALVE DETAIL
<br />5. EACH CONTROLLER SHALL HAVE ITS OWN GROUND ROD. SEPARATE
<br />THE GROUND RODS BY A MINIMUM OF EIGHT FEET. THE GROUND
<br />ROD SHALL BE AN EIGHT FOOT LONG BY 5/8" DIAMETER U.L.
<br />APPROVED COPPER CLAD ROD. NO MORE THAN 6" OF THE GROUND
<br />ROD TO BE ABOVE GRADE. CONNECT #8 GAUGE WIRE WITH A U.L.
<br />APPROVED GROUND ROD CLAMP TO ROD AND BACK TO GROUND
<br />SCREW AT BASE OF CONTROLLER WITH APPROPRIATE CONNECTOR.
<br />THIS WIRE SHOULD BE AS SHORT AS POSSIBLE, AVOIDING ANY KINKS
<br />OR BENDING.
<br />6. EACH IRRIGATION CONTROLLER TO HAVE ITS OWN- INDEPENDENT 24
<br />VOLT COMMON GROUND WIRE.
<br />7. IRRIGATION CONTROL WIRES SHALL BE COPPER WITH U.L. APPROVAL
<br />FOR DIRECT BURIAL IN GROUND, SIZE #14-1. COMMON GROUND
<br />WIRE SHALL HAVE WHITE INSULATING JACKET. CONTROL WIRE
<br />SHALL HAVE INSULATING JACKET OF COLOR OTHER THAN WHITE.
<br />SPLICE SHALL BE MADE WITH 3M-DBY SEAL PACKS.
<br />8. INSTALL SPARE CONTROL WIRE OF A DIFFERENT COLOR ALONG THE
<br />ENTIRE MAIN LINE. LOOP 36" EXCESS WIRE INTO EACH SINGLE VALVE
<br />BOX AND INTO ONE VALVE BOX IN EACH GROUP OF VALVES.
<br />9. SPLICING OF 24 VOLT WIRES IS NOT PERMITTED EXCEPT IN VALVE
<br />BOXES. LEAVE A 36" LONG, 1" DIAMETER COIL OF EXCESS WIRE AT
<br />EACH SPLICE AND A 36" LONG EXPANSION LOOP EVERY 100 FEET
<br />ALONG WIRE RUN. TAPE WIRES TOGETHER EVERY TEN FEET. TAPING
<br />WIRES IS NOT REQUIRED INSIDE SLEEVES.
<br />10. PLASTIC VALVE BOXES ARE TO BE GREEN IN COLOR WITH BOLT
<br />DOWN, NON -HINGED COVER MARKED "IRRIGATION". BOX BODY SHALL
<br />HAVE KNOCK OUTS. MANUFACTURER SHALL BE BROOKS OR CARSON.
<br />11. INSTALL REMOTE CONTROL VALVE BOXES 12" FROM WALK, CURB,
<br />LAWN, HEADER BOARD, BUILDING, OR LANDSCAPE FEATURE. AT
<br />MULTIPLE VALVE BOX GROUPS, EACH BOX SHALL BE AN EQUAL
<br />DISTANCE FROM THE WALK, CURB, LAWN, ETC. AND EACH BOX SHALL
<br />BE 12" APART. SHORT SIDE OF RECTANGULAR VALVE BOXES SHALL
<br />BE PARALLEL TO WALK, CURB, LAWN, ETC.
<br />12. FOR 2 1/2" AND LARGER MAIN LINE PIPING INSIDE SLEEVES USE 1120-
<br />315 PSI PVC PLASTIC PIPE WITH SCHEDULE 40 PVC COUPLINGS. NO
<br />RING-TITE COUPLINGS INSIDE SLEEVES.
<br />13. THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL
<br />SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO PREVENT
<br />OVER SPRAY ONTO WALKS, ROADWAYS, AND/OR BUILDINGS AS MUCH
<br />AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST DEGREE
<br />OF ARC TO FIT THE EXISTING SITE CONDITIONS AND TO THROTTLE
<br />THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM
<br />OPERATING PRESSURE FOR EACH SYSTEM.
<br />14. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH
<br />GRADE OF THE AREA TO BE IRRIGATED UNLESS OTHERWISE NOTED
<br />ON THE DRAWINGS.
<br />15. LOCATE BUBBLERS ON UP -HILL SIDE OF PLANT OR TREE.
<br />16. AT LOCATIONS WHERE LOW SPRINKLER HEAD DRAINAGE WILL CAUSE
<br />EROSION AND/OR EXCESS WATER, USE A RAIN BIRD 1800 -SAM SERIES
<br />POP-UP BODY WITH INTEGRAL CHECK VALVE AND A VALCON 5000
<br />SERIES SPRING LOADED CHECK VALVE ON SHRUB RISERS IN LIEU OF
<br />SCHEDULE 80 COUPLING.
<br />17. WHERE IT IS NECESSARY TO EXCAVATE ADJACENT TO EXISTING
<br />TREES, THE CONTRACTOR SHALL USE ALL POSSIBLE CARE TO AVOID
<br />INJURY TO TREES AND TREE ROOTS. EXCAVATION IN AREAS WHERE
<br />TWO (2) INCH AND LARGER ROOTS OCCUR SHALL BE DONE BY HAND.
<br />ROOTS ONE (1) INCH AND LARGER IN DIAMETER SHALL BE PAINTED
<br />WITH TWO COATS OF TREE SEAL, OR EQUAL. TRENCHES ADJACENT
<br />TO TREE SHOULD BE CLOSED WITHIN TWENTY-FOUR (24) HOURS;
<br />AND INHERE THIS IS NOT POSSIBLE, THE SIDE OF THE TRENCH
<br />ADJACENT TO THE TREE SHALL BE KEPT SHADED WITH BURLAP OR
<br />CANVAS.
<br />18. IRRIGATION CONTRACTOR TO NOTIFY ALL LOCAL JURISDICTIONS
<br />FOR INSPECTION AND TESTING OF INSTALLED BACKFLOW
<br />PREVENTION DEVICE.
<br />19. THE SPRINKLER SYSTEM DESIGN IS BASED ON THE MINIMUM
<br />OPERATING PRESSURE SHOWN ON THE IRRIGATION DRAWINGS. THE
<br />IRRIGATION CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR
<br />TO CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE
<br />WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL
<br />PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO
<br />THE OWNER'S AUTHORIZED REPRESENTATIVE.
<br />20. IRRIGATION DEMAND: ISo GPM AT 60 PSI STATIC PRESSURE AT
<br />IRRIGATION POINT OF CONNECTION.
<br />21. THE EXISTING MAIN LINE SHOWN ON THE DRAWINGS IS
<br />DIAGRAMMATIC. CONTRACTOR TO VERIFY AND LOCATE EXISTING
<br />MAIN LINE IN FIELD. ANY DEVIATION OF EXISTING MAIN LINE
<br />LOCATION AS SHOWN ON THE DRAWINGS IS TO BE REPORTED TO
<br />ARCHITECT FOR REVIEW AND POSSIBLE REVISION.
<br />22. COLOR CODE WIRES FOR EASE OF IDENTIFICATION BY PROVIDING A
<br />DIFFERENT COLOR CONTROL WIRE FOR ADJACENT CONTROLLERS.
<br />23. PIPE THREAD SEALANT COMPOUND SHALL BE LASCO #905-305,
<br />PERMATEX 51 OR RECTOR SEAL T+2.
<br />24. THE CONTRACTOR SHALL EXERCISE CARE WHEN WORKING IN AREAS
<br />ADJACENT TO EXISTING PLANTING AND IRRIGATION TO REMAIN.
<br />EXISTING TREES, SHRUBS, LAWNS AND OTHER PLANT MATERIALS TO
<br />REMAIN SHALL BE PROTECTED AT ALL TIMES. IRRIGATION LINES
<br />SERVICING EXISTING PLANTING AREAS TO REMAIN SHALL BE CUT
<br />AND TEMPORARILY CAPPED DURING DEMOLITION AND RESTORED TO
<br />FULL OPERATION UNDER THIS CONTRACT UNLESS SPECIFICALLY
<br />NOTED ON THE PLANS AS BEING OTHERWISE. CONTRACTOR SHALL
<br />PROVIDE TEMPORARY IRRIGATION IN THESE AREAS UNTIL
<br />IRRIGATION CAN BE FULLY RESTORED. EXISTING PLANT MATERIALS
<br />SHALL BE MAINTAINED IN A HEALTHY CONDITION UNLESS
<br />OTHERWISE NOTED ON THE PLANS AS BEING REMOVED OR
<br />REPLACED. SAN JOAQUIN
<br />GENERAL HOSPITAL
<br />REPLACEMENT PROJECT,
<br />PHASE 1A
<br />IRRIGATION DETAILS
<br />& NOTES
<br />Irrigation Consultant: Scale: NONE
<br />Russell D. Mitchell & Assoclates, Inc.
<br />2760 Camino Diablo
<br />Stone
<br />Marrabcini
<br />Patterson
<br />Architecture
<br />Planning
<br />Interior Architecture
<br />One Market Plaza
<br />Spear Street Tower
<br />Suite 400
<br />San Francisco
<br />CA 94105
<br />415 227-0100
<br />Architect,AIA
<br />Tech. Checked Tech.
<br />Coord. Arch.
<br />RUTHERFORD & CHEKENE
<br />303 Second St. Suite 800 N.
<br />San Francisco, CA 94107
<br />Structural Engineer
<br />GUTMANN & MacRITCHIE
<br />1304 Sutter Street
<br />Son Francisco, CA 94109
<br />Mechanical Engineer
<br />THE ENGINEERING ENTERPRISE
<br />1305 Marino Village Parkway
<br />Alameda, CA 94501
<br />Electrical Engineer
<br />MPA DESIGN
<br />562 Mission Street
<br />San Francisco, CA 94105
<br />Landscape Architect
<br />Approvals
<br />Revisions
<br />90c;� RI:VIEW
<br />Date
<br />23 M2\11Z ()2
<br />Walnut Creek, CA 94596 Project No. Drawing N o_
<br />(510) 939-3985
<br />(510) 932-5671 FAX 53000.09
<br />Date
<br />L4nC0
<br />
|