Laserfiche WebLink
VALVE CONTROL WIRE - PROVIDE <br />3M DBY SEAL PACKS AT ALL SPLICES <br />AND 36" OF EXCESS OF WIRE IN A <br />1" DIAMETER COIL. <br />RECTANGULAR PLASTIC VALVE BOX <br />WITH BOLT DOWN LID. ONE VALVE PER <br />BOX - NO EXCEPTIONS. INSTALL BOX AS <br />SHOWN IN BOX INSTALLATION DETAIL. <br />TOP DIMENSION: 11 314"x 17" <br />(12" DEEP). <br />REMOTE CONTROL <br />VALVE WITH FLOW CONTROL illi <br />AND MANUAL BLEED <br />SCHEDULE 80 PVC <br />THREADED FITTINGS <br />(AS REQUIRED) I <br />PVC MAIN LINE <br />FINISH GRADE <br />I. <br />PEA GRAVEL - 4" <br />DEEP BELOW VALVE <br />(NO SOIL IN VALVE BOX) <br />BRICK - 1 EACH <br />CORNER <br />- UPC APPROVED PVC MAIN LINE - CAP AND <br />CLASS 200 PVC THRUST BLOCK IF AT END <br />O-RING SERVICE OF LINE. <br />TEE <br />REMOTE CONTROL VALVE DETAIL <br />SCHEDULE 40 <br />PVC MALE <br />ADAPTER <br />PVC LATERAL <br />LINE <br />LOWER LATERAL <br />LINE WITH SCH. <br />40 PVC 45° <br />ELBOWS <br />REFER TO <br />IRRIGATION <br />LEGEND <br />i I <br />IRRIGATION NOTES <br />1. THESE IRRIGATION DRAWINGS ARE DIAGRAMMATIC AND INDICATIVE <br />OF THE WORK TO BE INSTALLED. ALL PIPING, VALVES, ETC. SHOWN <br />WITHIN PAVED AREAS IS FOR CLARITY ONLY AND ARE TO BE <br />INSTALLED WITHIN PLANTING AREAS WHERE POSSIBLE. DUE TO THE <br />SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL <br />OFFSETS, FITTINGS, SLEEVES, ETC. WHICH MAY BE REQUIRED. THE <br />CONTRACTOR IS REQUIRED TO INVESTIGATE THE STRUCTURAL AND <br />FINISHED CONDITIONS AFFECTING ALL OF THE CONTRACT WORK <br />INCLUDING OBSTRUCTIONS, GRADE DIFFERENCES OR AREA <br />DIMENSIONAL DIFFERENCES WHICH MAY NOT HAVE BEEN <br />CONSIDERED IN THE ENGINEERING. IN THE EVENT OF FIELD <br />DIFFERENCES, THE CONTRACTOR IS REQUIRED TO PLAN THE <br />INSTALLATION WORK ACCORDINGLY BY NOTIFICATION AND <br />APPROVAL OF THE OWNER'S AUTHORIZED REPRESENTATIVE AND <br />ACCORDING TO THE CONTRACT SPECIFICATIONS. THE <br />CONTRACTOR IS ALSO REQUIRED TO NOTIFY AND COORDINATE <br />IRRIGATION CONTRACT WORK WITH ALL APPLICABLE CONTRACTORS <br />FOR THE LOCATION AND INSTALLATION OF PIPE, CONDUIT OR <br />SLEEVES THROUGH OR UNDER WALLS, ROADWAYS, PAVING, <br />STRUCTURE, ETC. BEFORE CONSTRUCTION. IN THE EVENT THESE <br />NOTIFICATIONS ARE NOT PERFORMED, THE CONTRACTOR SHALL <br />ASSUME FULL RESPONSIBILITY FOR ALL REQUIRED REVISIONS. <br />2. THE INTENT OF THIS IRRIGATION SYSTEM IS TO PROVIDE THE <br />MINIMUM AMOUNT OF WATER REQUIRED TO SUSTAIN GOOD PLANT <br />HEALTH.- <br />3. <br />EALTH.-3. IT IS THE RESPONSIBILITY OF THE LANDSCAPE MAINTENANCE <br />CONTRACTOR AND/OR OWNER TO PROGRAM THE IRRIGATION <br />CONTROLLERS TO PROVIDE THE MINIMUM AMOUNT OF WATER <br />NEEDED TO SUSTAIN GOOD PLANT HEALTH. THIS INCLUDES MAKING <br />ADJUSTMENTS TO THE PROGRAM FOR SEASONAL WEATHER <br />CHANGES, PLANT MATERIAL, WATER REQUIREMENTS, MOUNDS AND <br />SLOPES, SUN, SHADE AND WIND EXPOSURES. <br />4. 120 VOLT A.C. (2.5 AMP DEMAND PER CONTROLLER) ELECTRICAL <br />SERVICE TO IRRIGATION CONTROLLER LOCATIONS TO BE PROVIDED <br />UNDER ELECTRICAL CONTRACT WORK. IRRIGATION CONTRACTOR <br />TO MAKE FINAL CONNECTION FROM ELECTRICAL STUB -OUT TO <br />CONTROLLERS AND PROVIDE PROPER GROUNDING PER <br />CONTROLLER MANUFACTURER'S INSTRUCTIONS. <br />TSI STRONG BOX COLD ROLLED <br />STEEL CONTROLLER ENCLOSURE ENCLOSURE <br />MODEL IISB-18 CR. DOOR <br />19� <br />CONTROLLER TO BE MOUNTED ON <br />MOUNTING PANEL OF ENCLOSURE <br />000 1 <br />TSI STRONG BOX CONTROLLER p°O <br />SUBASSEMBLY#CSA <br />#10 BARE COPPER - - - -1 <br />36' GROUND WIRE I I 2 <br />STEEL BASE WITH MOUNTING <br />STUDS INCLUDED WITH I <br />ENCLOSURE I I ROUND PLASTIC VALVE BOX <br />I WITH BOLT DOWN LID. <br />L_ e _ J <br />O TOP DIMENSION: 10". FINISH GRADE <br />FINISH GRADE - <br />�IIII '. • .. • Ilj�_ =III ' L= 18. L 3. <br />�• . • ,. : = 1' _ i II PEA GRAVEL <br />6' THICK CONCRETE SLAB TO 3 4 5 BRICK- 2 TOTAL <br />EXTEND 6' BEYOND THREE SIDES LOW VOLTAGE CONTROL <br />OF ENCLOSURE AND 12' BEYOND WIRES (EXTEND CONDUIT REFER TO IRRIGATION <br />FRONT. 12' BEYOND CONCRETE <br />LEGEND <br />120 VOLT A.C. ELECTRICAL SERVICE FROM SOURCE TO CONTROLLER SLAB) a� GATE VALVE WITH 2" <br />LOCATION PROVIDE BY ELECTRICAL CONTRACTOR. IRRIGATION SCHEDULE 40 GREY OPERATING NUT <br />CONTRACTOR TO PROVIDE RIGID STEEL CONDUIT FROM SERVICE PVC ELECTRICAL (O RING CONNECTION) <br />STUB -OUT TO CONTROLLER GCFI SWITCH AND COMPLETE <br />ELECTRICAL SERVICE TO CONTROLLER. CONDUIT WITH SWEEP O- RING PVC 8" CLASS 160 OR SCHEDULE 40 <br />ELL FOR LOW VOLTAGE OOOODUU MAIN LINE PVC PIPE (NOTCH TO FIT OVER <br />WIRE PROVIDED UNDER MAJN LINE PIPE) <br />SIDE VIEW FRONT VIEW <br />IRRIGATION CONTRACT. INSTRUCTIONS: <br />8' GROUNOtNG ROD 1. STRIP WIRES APPROXIMATELY 1/2" (12.7 MM) TO EXPOSE WIRE. <br />(INSIDE ENCLOSURE) 2. TWIST CONNECTOR AROUND WIRES CLOCKWISE UNTIL HAND TIGHT, DO NOT OVERTIGHTEN. >IS <br />3. INSERT WIRE ASSEMBLY INTO PLASTIC TUBE UNTIL WIRE CONNECTOR SNAPS PAST LIP IN #4 REBAR BEND OVER �, CONCRETE THRUST BLOCK <br />BOTTOM OF TUBE. 4 ' � <br />4. PLACE WIRES WHICH EXIT TUBE IN WIRE EXIT HOLES AND CLOSE CAP UNTIL IT SNAPS. VALVE BODY <br />5. INSPECT FINAL SPLICE ASSEMBLY TO BE SECURE AND FINISHED. <br />CONTROLLER IN 4T WEATHERPROOF SPLICE ASSEMBLY DETAIL 3' ENCLOSURE DETAIL 1 AND LARGER <br />GATE VALVE DETAIL <br />SEE LEGEND FOR <br />MAIN LINE DEPTH <br />-6.. � r --CURB OR WALK <br />wtUnl VARIES - <br />COMMON TRENCH DETAIL <br />lU' LATERAL LINE <br />o� <br />-2" <br />-- - 3" NI:I. <br />CONTROL WIR[� <br />R11N LINE <br />NOTE* NIPPLES AND FITTINGS TO BE SAME SIZE <br />DIAIIETER OF ,-CURB OR WALK AS VALVE IPT INLET THREAD SIZE. <br />PIPE PLUS 4 f_ QUICK COUPLING VALVE <br />(SET AT FINISH GRADE IN <br />fl�j= SINGLE LINE TRENCH DETAIL 12" TURF AREAS - WHERE <br />APPLICABLE) <br />FINISH GRADE ROUND PLASTIC VALVE BOX WITH <br />'•'. 1" BOLT DOWN LID. TOP DIMENSION: 10". <br />LLATERAL LINE-12"IIlI FINISH GRADE <br />WALL, WALK, <br />hV1IN LINE- SEE LEGEND CURB OR HEADER <br />REFER TO IRRIGATION SCHEDULE 80 PVC=11 g <br />CONTROL WIRE -18" LE END THREADED NIPPLE :5 3" <br />4 AT CONDUIT - <br />10" LONG SCHEDULE 80 II)] PEA GRAVEL <br />6" AT SLEEVING - -REPLACE TO MATCH EXISTING PAVING PVC THREADED NIPPLE <br />{-EXISTING A.C. PAVING <br />L11- 111/1 REFER TO IRRIGATION <br />BRICK 2 TOTAL <br />_ BACKFILL TO BE LEGEND <br />24 IIIA COMPACTED TO 95% SIDE VIEW <br />TRENCHING UNDER PAVING PVC MAIN LINE UPC APPROVED SCHEDULE <br />40 PVC TEE OR ELBOW ° <br />GATE VALVE <br />• <br />8" CLASS 160 OR SCHEDULE 40 PVC <br />CONDUIT FOR CONTROL WIRE OR 3" LONG SCHEDULE 80 PIPE (NOTCH TO FIT OVER MAIN <br />LINE PIPE) <br />SLEEYIi1G FOR MAIN AND/OR LATERAL LINES <br />PVC THREADED NIPPLE <br />i. IF THE EXCAVATED NATIVE MATERIAL IS LARGER THAN 3/4" DIA., IT SHALL BE THE RESPONSIBILITY <br />OF THE GENERAL CONTRACTOR TO PROVIDE THE SUITABLE BACKFILL I•IATERIAL. THE SUITABILITY OF LL -A <br />THE BACKFILL MATERIAL SHALL BE DETERIII14ED AT THE CITY'S DISCRETION. THE AFOREMENTIONED SCHEDULE 80 PVC <br />14ATERIAL SHALL BE COMPACTED TO 90% RELATIVE COMPACTION. BACKFILL MATERIAL SHALL BE THREADED 900 ELL CLASS 200 PVC <br />EXCAVATED NATIVE 14ATERIAL THAT IS CLEAR OF ALL DEBRIS AND ROCKS LARGER THAN 1/4" IN <br />MALE x BELL ADAPTER <br />DIAMETER. <br />2. PROVIDE 24" SEPARATION BETWEEN IRRIGATION LILIES AND VARIOUS UTILITIES. TOP VIEW PVC MAIN LINE <br />TRENCHING DETAIL 5 QUICK COUPLING VALVE DETAIL 2 2 1/2SMALLER <br />GATE VALVE DETAIL <br />5. EACH CONTROLLER SHALL HAVE ITS OWN GROUND ROD. SEPARATE <br />THE GROUND RODS BY A MINIMUM OF EIGHT FEET. THE GROUND <br />ROD SHALL BE AN EIGHT FOOT LONG BY 5/8" DIAMETER U.L. <br />APPROVED COPPER CLAD ROD. NO MORE THAN 6" OF THE GROUND <br />ROD TO BE ABOVE GRADE. CONNECT #8 GAUGE WIRE WITH A U.L. <br />APPROVED GROUND ROD CLAMP TO ROD AND BACK TO GROUND <br />SCREW AT BASE OF CONTROLLER WITH APPROPRIATE CONNECTOR. <br />THIS WIRE SHOULD BE AS SHORT AS POSSIBLE, AVOIDING ANY KINKS <br />OR BENDING. <br />6. EACH IRRIGATION CONTROLLER TO HAVE ITS OWN- INDEPENDENT 24 <br />VOLT COMMON GROUND WIRE. <br />7. IRRIGATION CONTROL WIRES SHALL BE COPPER WITH U.L. APPROVAL <br />FOR DIRECT BURIAL IN GROUND, SIZE #14-1. COMMON GROUND <br />WIRE SHALL HAVE WHITE INSULATING JACKET. CONTROL WIRE <br />SHALL HAVE INSULATING JACKET OF COLOR OTHER THAN WHITE. <br />SPLICE SHALL BE MADE WITH 3M-DBY SEAL PACKS. <br />8. INSTALL SPARE CONTROL WIRE OF A DIFFERENT COLOR ALONG THE <br />ENTIRE MAIN LINE. LOOP 36" EXCESS WIRE INTO EACH SINGLE VALVE <br />BOX AND INTO ONE VALVE BOX IN EACH GROUP OF VALVES. <br />9. SPLICING OF 24 VOLT WIRES IS NOT PERMITTED EXCEPT IN VALVE <br />BOXES. LEAVE A 36" LONG, 1" DIAMETER COIL OF EXCESS WIRE AT <br />EACH SPLICE AND A 36" LONG EXPANSION LOOP EVERY 100 FEET <br />ALONG WIRE RUN. TAPE WIRES TOGETHER EVERY TEN FEET. TAPING <br />WIRES IS NOT REQUIRED INSIDE SLEEVES. <br />10. PLASTIC VALVE BOXES ARE TO BE GREEN IN COLOR WITH BOLT <br />DOWN, NON -HINGED COVER MARKED "IRRIGATION". BOX BODY SHALL <br />HAVE KNOCK OUTS. MANUFACTURER SHALL BE BROOKS OR CARSON. <br />11. INSTALL REMOTE CONTROL VALVE BOXES 12" FROM WALK, CURB, <br />LAWN, HEADER BOARD, BUILDING, OR LANDSCAPE FEATURE. AT <br />MULTIPLE VALVE BOX GROUPS, EACH BOX SHALL BE AN EQUAL <br />DISTANCE FROM THE WALK, CURB, LAWN, ETC. AND EACH BOX SHALL <br />BE 12" APART. SHORT SIDE OF RECTANGULAR VALVE BOXES SHALL <br />BE PARALLEL TO WALK, CURB, LAWN, ETC. <br />12. FOR 2 1/2" AND LARGER MAIN LINE PIPING INSIDE SLEEVES USE 1120- <br />315 PSI PVC PLASTIC PIPE WITH SCHEDULE 40 PVC COUPLINGS. NO <br />RING-TITE COUPLINGS INSIDE SLEEVES. <br />13. THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL <br />SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO PREVENT <br />OVER SPRAY ONTO WALKS, ROADWAYS, AND/OR BUILDINGS AS MUCH <br />AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST DEGREE <br />OF ARC TO FIT THE EXISTING SITE CONDITIONS AND TO THROTTLE <br />THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM <br />OPERATING PRESSURE FOR EACH SYSTEM. <br />14. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH <br />GRADE OF THE AREA TO BE IRRIGATED UNLESS OTHERWISE NOTED <br />ON THE DRAWINGS. <br />15. LOCATE BUBBLERS ON UP -HILL SIDE OF PLANT OR TREE. <br />16. AT LOCATIONS WHERE LOW SPRINKLER HEAD DRAINAGE WILL CAUSE <br />EROSION AND/OR EXCESS WATER, USE A RAIN BIRD 1800 -SAM SERIES <br />POP-UP BODY WITH INTEGRAL CHECK VALVE AND A VALCON 5000 <br />SERIES SPRING LOADED CHECK VALVE ON SHRUB RISERS IN LIEU OF <br />SCHEDULE 80 COUPLING. <br />17. WHERE IT IS NECESSARY TO EXCAVATE ADJACENT TO EXISTING <br />TREES, THE CONTRACTOR SHALL USE ALL POSSIBLE CARE TO AVOID <br />INJURY TO TREES AND TREE ROOTS. EXCAVATION IN AREAS WHERE <br />TWO (2) INCH AND LARGER ROOTS OCCUR SHALL BE DONE BY HAND. <br />ROOTS ONE (1) INCH AND LARGER IN DIAMETER SHALL BE PAINTED <br />WITH TWO COATS OF TREE SEAL, OR EQUAL. TRENCHES ADJACENT <br />TO TREE SHOULD BE CLOSED WITHIN TWENTY-FOUR (24) HOURS; <br />AND INHERE THIS IS NOT POSSIBLE, THE SIDE OF THE TRENCH <br />ADJACENT TO THE TREE SHALL BE KEPT SHADED WITH BURLAP OR <br />CANVAS. <br />18. IRRIGATION CONTRACTOR TO NOTIFY ALL LOCAL JURISDICTIONS <br />FOR INSPECTION AND TESTING OF INSTALLED BACKFLOW <br />PREVENTION DEVICE. <br />19. THE SPRINKLER SYSTEM DESIGN IS BASED ON THE MINIMUM <br />OPERATING PRESSURE SHOWN ON THE IRRIGATION DRAWINGS. THE <br />IRRIGATION CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR <br />TO CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE <br />WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL <br />PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO <br />THE OWNER'S AUTHORIZED REPRESENTATIVE. <br />20. IRRIGATION DEMAND: ISo GPM AT 60 PSI STATIC PRESSURE AT <br />IRRIGATION POINT OF CONNECTION. <br />21. THE EXISTING MAIN LINE SHOWN ON THE DRAWINGS IS <br />DIAGRAMMATIC. CONTRACTOR TO VERIFY AND LOCATE EXISTING <br />MAIN LINE IN FIELD. ANY DEVIATION OF EXISTING MAIN LINE <br />LOCATION AS SHOWN ON THE DRAWINGS IS TO BE REPORTED TO <br />ARCHITECT FOR REVIEW AND POSSIBLE REVISION. <br />22. COLOR CODE WIRES FOR EASE OF IDENTIFICATION BY PROVIDING A <br />DIFFERENT COLOR CONTROL WIRE FOR ADJACENT CONTROLLERS. <br />23. PIPE THREAD SEALANT COMPOUND SHALL BE LASCO #905-305, <br />PERMATEX 51 OR RECTOR SEAL T+2. <br />24. THE CONTRACTOR SHALL EXERCISE CARE WHEN WORKING IN AREAS <br />ADJACENT TO EXISTING PLANTING AND IRRIGATION TO REMAIN. <br />EXISTING TREES, SHRUBS, LAWNS AND OTHER PLANT MATERIALS TO <br />REMAIN SHALL BE PROTECTED AT ALL TIMES. IRRIGATION LINES <br />SERVICING EXISTING PLANTING AREAS TO REMAIN SHALL BE CUT <br />AND TEMPORARILY CAPPED DURING DEMOLITION AND RESTORED TO <br />FULL OPERATION UNDER THIS CONTRACT UNLESS SPECIFICALLY <br />NOTED ON THE PLANS AS BEING OTHERWISE. CONTRACTOR SHALL <br />PROVIDE TEMPORARY IRRIGATION IN THESE AREAS UNTIL <br />IRRIGATION CAN BE FULLY RESTORED. EXISTING PLANT MATERIALS <br />SHALL BE MAINTAINED IN A HEALTHY CONDITION UNLESS <br />OTHERWISE NOTED ON THE PLANS AS BEING REMOVED OR <br />REPLACED. SAN JOAQUIN <br />GENERAL HOSPITAL <br />REPLACEMENT PROJECT, <br />PHASE 1A <br />IRRIGATION DETAILS <br />& NOTES <br />Irrigation Consultant: Scale: NONE <br />Russell D. Mitchell & Assoclates, Inc. <br />2760 Camino Diablo <br />Stone <br />Marrabcini <br />Patterson <br />Architecture <br />Planning <br />Interior Architecture <br />One Market Plaza <br />Spear Street Tower <br />Suite 400 <br />San Francisco <br />CA 94105 <br />415 227-0100 <br />Architect,AIA <br />Tech. Checked Tech. <br />Coord. Arch. <br />RUTHERFORD & CHEKENE <br />303 Second St. Suite 800 N. <br />San Francisco, CA 94107 <br />Structural Engineer <br />GUTMANN & MacRITCHIE <br />1304 Sutter Street <br />Son Francisco, CA 94109 <br />Mechanical Engineer <br />THE ENGINEERING ENTERPRISE <br />1305 Marino Village Parkway <br />Alameda, CA 94501 <br />Electrical Engineer <br />MPA DESIGN <br />562 Mission Street <br />San Francisco, CA 94105 <br />Landscape Architect <br />Approvals <br />Revisions <br />90c;� RI:VIEW <br />Date <br />23 M2\11Z ()2 <br />Walnut Creek, CA 94596 Project No. Drawing N o_ <br />(510) 939-3985 <br />(510) 932-5671 FAX 53000.09 <br />Date <br />L4nC0 <br />NOTES: 1. NIPPLES AND FITTINGS TO BE SAME IPT SIZE AS <br />BACKFLOW ASSEMBLY. <br />2. DO NOT SOLDER CONNECT FITTINGS WHILE THREADED <br />INTO BACKFLOW ASSEMBLY. DAMAGE MAY OCCUR. <br />REDUCED PRESSURE <br />BACKFLOW ASSEMBLY <br />FLOW <br />BRASS CLOSE THREADED <br />NIPPLE (4 TOTAL) <br />BRASS 90' ELBOW- 2 TOTAL <br />BRASS UNION- 2 TOTAL <br />(FIPT CONNECTION) <br />(FIPT CONNECTION) <br />I ( I I <br />WROT COPPER MALE <br />ADAPTER- 2 TOTAL <br />- <br />(SOLDER x THREAD <br />CONNECTION) <br />- <br />COPPER TYPE "K" <br />12" - <br />PIPE (LENGTH AS <br />FINISH GRADE <br />REQUIRED) <br />II� <br />III <br />WROT COPPER 900 <br />- <br />REFER TO IRRIGATION <br />ELBOW- 2 TOTAL (SOLDER <br />LEGEND <br />x THREAD CONNECTION) <br />o <br />PVC MAIN LINE <br />BUSH AS NECESSARY CONCRETE SUPPORT <br />PVC MAIN LINE TO <br />TO POINT OF <br />FOR SIZE TRANSITION BLOCK <br />IRRIGATION SYSTEM <br />CONNECTION <br />CLASS 200 PVC O-RING x <br />MIPT MALE ADAPTER <br />2" -AND <br />6 <br />SMALLER REDUCED PRESSURE <br />3 <br />BACKFLOW ASSEMBLY <br />VALVE CONTROL WIRE - PROVIDE <br />3M DBY SEAL PACKS AT ALL SPLICES <br />AND 36" OF EXCESS OF WIRE IN A <br />1" DIAMETER COIL. <br />RECTANGULAR PLASTIC VALVE BOX <br />WITH BOLT DOWN LID. ONE VALVE PER <br />BOX - NO EXCEPTIONS. INSTALL BOX AS <br />SHOWN IN BOX INSTALLATION DETAIL. <br />TOP DIMENSION: 11 314"x 17" <br />(12" DEEP). <br />REMOTE CONTROL <br />VALVE WITH FLOW CONTROL illi <br />AND MANUAL BLEED <br />SCHEDULE 80 PVC <br />THREADED FITTINGS <br />(AS REQUIRED) I <br />PVC MAIN LINE <br />FINISH GRADE <br />I. <br />PEA GRAVEL - 4" <br />DEEP BELOW VALVE <br />(NO SOIL IN VALVE BOX) <br />BRICK - 1 EACH <br />CORNER <br />- UPC APPROVED PVC MAIN LINE - CAP AND <br />CLASS 200 PVC THRUST BLOCK IF AT END <br />O-RING SERVICE OF LINE. <br />TEE <br />REMOTE CONTROL VALVE DETAIL <br />SCHEDULE 40 <br />PVC MALE <br />ADAPTER <br />PVC LATERAL <br />LINE <br />LOWER LATERAL <br />LINE WITH SCH. <br />40 PVC 45° <br />ELBOWS <br />REFER TO <br />IRRIGATION <br />LEGEND <br />i I <br />IRRIGATION NOTES <br />1. THESE IRRIGATION DRAWINGS ARE DIAGRAMMATIC AND INDICATIVE <br />OF THE WORK TO BE INSTALLED. ALL PIPING, VALVES, ETC. SHOWN <br />WITHIN PAVED AREAS IS FOR CLARITY ONLY AND ARE TO BE <br />INSTALLED WITHIN PLANTING AREAS WHERE POSSIBLE. DUE TO THE <br />SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL <br />OFFSETS, FITTINGS, SLEEVES, ETC. WHICH MAY BE REQUIRED. THE <br />CONTRACTOR IS REQUIRED TO INVESTIGATE THE STRUCTURAL AND <br />FINISHED CONDITIONS AFFECTING ALL OF THE CONTRACT WORK <br />INCLUDING OBSTRUCTIONS, GRADE DIFFERENCES OR AREA <br />DIMENSIONAL DIFFERENCES WHICH MAY NOT HAVE BEEN <br />CONSIDERED IN THE ENGINEERING. IN THE EVENT OF FIELD <br />DIFFERENCES, THE CONTRACTOR IS REQUIRED TO PLAN THE <br />INSTALLATION WORK ACCORDINGLY BY NOTIFICATION AND <br />APPROVAL OF THE OWNER'S AUTHORIZED REPRESENTATIVE AND <br />ACCORDING TO THE CONTRACT SPECIFICATIONS. THE <br />CONTRACTOR IS ALSO REQUIRED TO NOTIFY AND COORDINATE <br />IRRIGATION CONTRACT WORK WITH ALL APPLICABLE CONTRACTORS <br />FOR THE LOCATION AND INSTALLATION OF PIPE, CONDUIT OR <br />SLEEVES THROUGH OR UNDER WALLS, ROADWAYS, PAVING, <br />STRUCTURE, ETC. BEFORE CONSTRUCTION. IN THE EVENT THESE <br />NOTIFICATIONS ARE NOT PERFORMED, THE CONTRACTOR SHALL <br />ASSUME FULL RESPONSIBILITY FOR ALL REQUIRED REVISIONS. <br />2. THE INTENT OF THIS IRRIGATION SYSTEM IS TO PROVIDE THE <br />MINIMUM AMOUNT OF WATER REQUIRED TO SUSTAIN GOOD PLANT <br />HEALTH.- <br />3. <br />EALTH.-3. IT IS THE RESPONSIBILITY OF THE LANDSCAPE MAINTENANCE <br />CONTRACTOR AND/OR OWNER TO PROGRAM THE IRRIGATION <br />CONTROLLERS TO PROVIDE THE MINIMUM AMOUNT OF WATER <br />NEEDED TO SUSTAIN GOOD PLANT HEALTH. THIS INCLUDES MAKING <br />ADJUSTMENTS TO THE PROGRAM FOR SEASONAL WEATHER <br />CHANGES, PLANT MATERIAL, WATER REQUIREMENTS, MOUNDS AND <br />SLOPES, SUN, SHADE AND WIND EXPOSURES. <br />4. 120 VOLT A.C. (2.5 AMP DEMAND PER CONTROLLER) ELECTRICAL <br />SERVICE TO IRRIGATION CONTROLLER LOCATIONS TO BE PROVIDED <br />UNDER ELECTRICAL CONTRACT WORK. IRRIGATION CONTRACTOR <br />TO MAKE FINAL CONNECTION FROM ELECTRICAL STUB -OUT TO <br />CONTROLLERS AND PROVIDE PROPER GROUNDING PER <br />CONTROLLER MANUFACTURER'S INSTRUCTIONS. <br />TSI STRONG BOX COLD ROLLED <br />STEEL CONTROLLER ENCLOSURE ENCLOSURE <br />MODEL IISB-18 CR. DOOR <br />19� <br />CONTROLLER TO BE MOUNTED ON <br />MOUNTING PANEL OF ENCLOSURE <br />000 1 <br />TSI STRONG BOX CONTROLLER p°O <br />SUBASSEMBLY#CSA <br />#10 BARE COPPER - - - -1 <br />36' GROUND WIRE I I 2 <br />STEEL BASE WITH MOUNTING <br />STUDS INCLUDED WITH I <br />ENCLOSURE I I ROUND PLASTIC VALVE BOX <br />I WITH BOLT DOWN LID. <br />L_ e _ J <br />O TOP DIMENSION: 10". FINISH GRADE <br />FINISH GRADE - <br />�IIII '. • .. • Ilj�_ =III ' L= 18. L 3. <br />�• . • ,. : = 1' _ i II PEA GRAVEL <br />6' THICK CONCRETE SLAB TO 3 4 5 BRICK- 2 TOTAL <br />EXTEND 6' BEYOND THREE SIDES LOW VOLTAGE CONTROL <br />OF ENCLOSURE AND 12' BEYOND WIRES (EXTEND CONDUIT REFER TO IRRIGATION <br />FRONT. 12' BEYOND CONCRETE <br />LEGEND <br />120 VOLT A.C. ELECTRICAL SERVICE FROM SOURCE TO CONTROLLER SLAB) a� GATE VALVE WITH 2" <br />LOCATION PROVIDE BY ELECTRICAL CONTRACTOR. IRRIGATION SCHEDULE 40 GREY OPERATING NUT <br />CONTRACTOR TO PROVIDE RIGID STEEL CONDUIT FROM SERVICE PVC ELECTRICAL (O RING CONNECTION) <br />STUB -OUT TO CONTROLLER GCFI SWITCH AND COMPLETE <br />ELECTRICAL SERVICE TO CONTROLLER. CONDUIT WITH SWEEP O- RING PVC 8" CLASS 160 OR SCHEDULE 40 <br />ELL FOR LOW VOLTAGE OOOODUU MAIN LINE PVC PIPE (NOTCH TO FIT OVER <br />WIRE PROVIDED UNDER MAJN LINE PIPE) <br />SIDE VIEW FRONT VIEW <br />IRRIGATION CONTRACT. INSTRUCTIONS: <br />8' GROUNOtNG ROD 1. STRIP WIRES APPROXIMATELY 1/2" (12.7 MM) TO EXPOSE WIRE. <br />(INSIDE ENCLOSURE) 2. TWIST CONNECTOR AROUND WIRES CLOCKWISE UNTIL HAND TIGHT, DO NOT OVERTIGHTEN. >IS <br />3. INSERT WIRE ASSEMBLY INTO PLASTIC TUBE UNTIL WIRE CONNECTOR SNAPS PAST LIP IN #4 REBAR BEND OVER �, CONCRETE THRUST BLOCK <br />BOTTOM OF TUBE. 4 ' � <br />4. PLACE WIRES WHICH EXIT TUBE IN WIRE EXIT HOLES AND CLOSE CAP UNTIL IT SNAPS. VALVE BODY <br />5. INSPECT FINAL SPLICE ASSEMBLY TO BE SECURE AND FINISHED. <br />CONTROLLER IN 4T WEATHERPROOF SPLICE ASSEMBLY DETAIL 3' ENCLOSURE DETAIL 1 AND LARGER <br />GATE VALVE DETAIL <br />SEE LEGEND FOR <br />MAIN LINE DEPTH <br />-6.. � r --CURB OR WALK <br />wtUnl VARIES - <br />COMMON TRENCH DETAIL <br />lU' LATERAL LINE <br />o� <br />-2" <br />-- - 3" NI:I. <br />CONTROL WIR[� <br />R11N LINE <br />NOTE* NIPPLES AND FITTINGS TO BE SAME SIZE <br />DIAIIETER OF ,-CURB OR WALK AS VALVE IPT INLET THREAD SIZE. <br />PIPE PLUS 4 f_ QUICK COUPLING VALVE <br />(SET AT FINISH GRADE IN <br />fl�j= SINGLE LINE TRENCH DETAIL 12" TURF AREAS - WHERE <br />APPLICABLE) <br />FINISH GRADE ROUND PLASTIC VALVE BOX WITH <br />'•'. 1" BOLT DOWN LID. TOP DIMENSION: 10". <br />LLATERAL LINE-12"IIlI FINISH GRADE <br />WALL, WALK, <br />hV1IN LINE- SEE LEGEND CURB OR HEADER <br />REFER TO IRRIGATION SCHEDULE 80 PVC=11 g <br />CONTROL WIRE -18" LE END THREADED NIPPLE :5 3" <br />4 AT CONDUIT - <br />10" LONG SCHEDULE 80 II)] PEA GRAVEL <br />6" AT SLEEVING - -REPLACE TO MATCH EXISTING PAVING PVC THREADED NIPPLE <br />{-EXISTING A.C. PAVING <br />L11- 111/1 REFER TO IRRIGATION <br />BRICK 2 TOTAL <br />_ BACKFILL TO BE LEGEND <br />24 IIIA COMPACTED TO 95% SIDE VIEW <br />TRENCHING UNDER PAVING PVC MAIN LINE UPC APPROVED SCHEDULE <br />40 PVC TEE OR ELBOW ° <br />GATE VALVE <br />• <br />8" CLASS 160 OR SCHEDULE 40 PVC <br />CONDUIT FOR CONTROL WIRE OR 3" LONG SCHEDULE 80 PIPE (NOTCH TO FIT OVER MAIN <br />LINE PIPE) <br />SLEEYIi1G FOR MAIN AND/OR LATERAL LINES <br />PVC THREADED NIPPLE <br />i. IF THE EXCAVATED NATIVE MATERIAL IS LARGER THAN 3/4" DIA., IT SHALL BE THE RESPONSIBILITY <br />OF THE GENERAL CONTRACTOR TO PROVIDE THE SUITABLE BACKFILL I•IATERIAL. THE SUITABILITY OF LL -A <br />THE BACKFILL MATERIAL SHALL BE DETERIII14ED AT THE CITY'S DISCRETION. THE AFOREMENTIONED SCHEDULE 80 PVC <br />14ATERIAL SHALL BE COMPACTED TO 90% RELATIVE COMPACTION. BACKFILL MATERIAL SHALL BE THREADED 900 ELL CLASS 200 PVC <br />EXCAVATED NATIVE 14ATERIAL THAT IS CLEAR OF ALL DEBRIS AND ROCKS LARGER THAN 1/4" IN <br />MALE x BELL ADAPTER <br />DIAMETER. <br />2. PROVIDE 24" SEPARATION BETWEEN IRRIGATION LILIES AND VARIOUS UTILITIES. TOP VIEW PVC MAIN LINE <br />TRENCHING DETAIL 5 QUICK COUPLING VALVE DETAIL 2 2 1/2SMALLER <br />GATE VALVE DETAIL <br />5. EACH CONTROLLER SHALL HAVE ITS OWN GROUND ROD. SEPARATE <br />THE GROUND RODS BY A MINIMUM OF EIGHT FEET. THE GROUND <br />ROD SHALL BE AN EIGHT FOOT LONG BY 5/8" DIAMETER U.L. <br />APPROVED COPPER CLAD ROD. NO MORE THAN 6" OF THE GROUND <br />ROD TO BE ABOVE GRADE. CONNECT #8 GAUGE WIRE WITH A U.L. <br />APPROVED GROUND ROD CLAMP TO ROD AND BACK TO GROUND <br />SCREW AT BASE OF CONTROLLER WITH APPROPRIATE CONNECTOR. <br />THIS WIRE SHOULD BE AS SHORT AS POSSIBLE, AVOIDING ANY KINKS <br />OR BENDING. <br />6. EACH IRRIGATION CONTROLLER TO HAVE ITS OWN- INDEPENDENT 24 <br />VOLT COMMON GROUND WIRE. <br />7. IRRIGATION CONTROL WIRES SHALL BE COPPER WITH U.L. APPROVAL <br />FOR DIRECT BURIAL IN GROUND, SIZE #14-1. COMMON GROUND <br />WIRE SHALL HAVE WHITE INSULATING JACKET. CONTROL WIRE <br />SHALL HAVE INSULATING JACKET OF COLOR OTHER THAN WHITE. <br />SPLICE SHALL BE MADE WITH 3M-DBY SEAL PACKS. <br />8. INSTALL SPARE CONTROL WIRE OF A DIFFERENT COLOR ALONG THE <br />ENTIRE MAIN LINE. LOOP 36" EXCESS WIRE INTO EACH SINGLE VALVE <br />BOX AND INTO ONE VALVE BOX IN EACH GROUP OF VALVES. <br />9. SPLICING OF 24 VOLT WIRES IS NOT PERMITTED EXCEPT IN VALVE <br />BOXES. LEAVE A 36" LONG, 1" DIAMETER COIL OF EXCESS WIRE AT <br />EACH SPLICE AND A 36" LONG EXPANSION LOOP EVERY 100 FEET <br />ALONG WIRE RUN. TAPE WIRES TOGETHER EVERY TEN FEET. TAPING <br />WIRES IS NOT REQUIRED INSIDE SLEEVES. <br />10. PLASTIC VALVE BOXES ARE TO BE GREEN IN COLOR WITH BOLT <br />DOWN, NON -HINGED COVER MARKED "IRRIGATION". BOX BODY SHALL <br />HAVE KNOCK OUTS. MANUFACTURER SHALL BE BROOKS OR CARSON. <br />11. INSTALL REMOTE CONTROL VALVE BOXES 12" FROM WALK, CURB, <br />LAWN, HEADER BOARD, BUILDING, OR LANDSCAPE FEATURE. AT <br />MULTIPLE VALVE BOX GROUPS, EACH BOX SHALL BE AN EQUAL <br />DISTANCE FROM THE WALK, CURB, LAWN, ETC. AND EACH BOX SHALL <br />BE 12" APART. SHORT SIDE OF RECTANGULAR VALVE BOXES SHALL <br />BE PARALLEL TO WALK, CURB, LAWN, ETC. <br />12. FOR 2 1/2" AND LARGER MAIN LINE PIPING INSIDE SLEEVES USE 1120- <br />315 PSI PVC PLASTIC PIPE WITH SCHEDULE 40 PVC COUPLINGS. NO <br />RING-TITE COUPLINGS INSIDE SLEEVES. <br />13. THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL <br />SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO PREVENT <br />OVER SPRAY ONTO WALKS, ROADWAYS, AND/OR BUILDINGS AS MUCH <br />AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST DEGREE <br />OF ARC TO FIT THE EXISTING SITE CONDITIONS AND TO THROTTLE <br />THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM <br />OPERATING PRESSURE FOR EACH SYSTEM. <br />14. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH <br />GRADE OF THE AREA TO BE IRRIGATED UNLESS OTHERWISE NOTED <br />ON THE DRAWINGS. <br />15. LOCATE BUBBLERS ON UP -HILL SIDE OF PLANT OR TREE. <br />16. AT LOCATIONS WHERE LOW SPRINKLER HEAD DRAINAGE WILL CAUSE <br />EROSION AND/OR EXCESS WATER, USE A RAIN BIRD 1800 -SAM SERIES <br />POP-UP BODY WITH INTEGRAL CHECK VALVE AND A VALCON 5000 <br />SERIES SPRING LOADED CHECK VALVE ON SHRUB RISERS IN LIEU OF <br />SCHEDULE 80 COUPLING. <br />17. WHERE IT IS NECESSARY TO EXCAVATE ADJACENT TO EXISTING <br />TREES, THE CONTRACTOR SHALL USE ALL POSSIBLE CARE TO AVOID <br />INJURY TO TREES AND TREE ROOTS. EXCAVATION IN AREAS WHERE <br />TWO (2) INCH AND LARGER ROOTS OCCUR SHALL BE DONE BY HAND. <br />ROOTS ONE (1) INCH AND LARGER IN DIAMETER SHALL BE PAINTED <br />WITH TWO COATS OF TREE SEAL, OR EQUAL. TRENCHES ADJACENT <br />TO TREE SHOULD BE CLOSED WITHIN TWENTY-FOUR (24) HOURS; <br />AND INHERE THIS IS NOT POSSIBLE, THE SIDE OF THE TRENCH <br />ADJACENT TO THE TREE SHALL BE KEPT SHADED WITH BURLAP OR <br />CANVAS. <br />18. IRRIGATION CONTRACTOR TO NOTIFY ALL LOCAL JURISDICTIONS <br />FOR INSPECTION AND TESTING OF INSTALLED BACKFLOW <br />PREVENTION DEVICE. <br />19. THE SPRINKLER SYSTEM DESIGN IS BASED ON THE MINIMUM <br />OPERATING PRESSURE SHOWN ON THE IRRIGATION DRAWINGS. THE <br />IRRIGATION CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR <br />TO CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE <br />WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL <br />PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO <br />THE OWNER'S AUTHORIZED REPRESENTATIVE. <br />20. IRRIGATION DEMAND: ISo GPM AT 60 PSI STATIC PRESSURE AT <br />IRRIGATION POINT OF CONNECTION. <br />21. THE EXISTING MAIN LINE SHOWN ON THE DRAWINGS IS <br />DIAGRAMMATIC. CONTRACTOR TO VERIFY AND LOCATE EXISTING <br />MAIN LINE IN FIELD. ANY DEVIATION OF EXISTING MAIN LINE <br />LOCATION AS SHOWN ON THE DRAWINGS IS TO BE REPORTED TO <br />ARCHITECT FOR REVIEW AND POSSIBLE REVISION. <br />22. COLOR CODE WIRES FOR EASE OF IDENTIFICATION BY PROVIDING A <br />DIFFERENT COLOR CONTROL WIRE FOR ADJACENT CONTROLLERS. <br />23. PIPE THREAD SEALANT COMPOUND SHALL BE LASCO #905-305, <br />PERMATEX 51 OR RECTOR SEAL T+2. <br />24. THE CONTRACTOR SHALL EXERCISE CARE WHEN WORKING IN AREAS <br />ADJACENT TO EXISTING PLANTING AND IRRIGATION TO REMAIN. <br />EXISTING TREES, SHRUBS, LAWNS AND OTHER PLANT MATERIALS TO <br />REMAIN SHALL BE PROTECTED AT ALL TIMES. IRRIGATION LINES <br />SERVICING EXISTING PLANTING AREAS TO REMAIN SHALL BE CUT <br />AND TEMPORARILY CAPPED DURING DEMOLITION AND RESTORED TO <br />FULL OPERATION UNDER THIS CONTRACT UNLESS SPECIFICALLY <br />NOTED ON THE PLANS AS BEING OTHERWISE. CONTRACTOR SHALL <br />PROVIDE TEMPORARY IRRIGATION IN THESE AREAS UNTIL <br />IRRIGATION CAN BE FULLY RESTORED. EXISTING PLANT MATERIALS <br />SHALL BE MAINTAINED IN A HEALTHY CONDITION UNLESS <br />OTHERWISE NOTED ON THE PLANS AS BEING REMOVED OR <br />REPLACED. SAN JOAQUIN <br />GENERAL HOSPITAL <br />REPLACEMENT PROJECT, <br />PHASE 1A <br />IRRIGATION DETAILS <br />& NOTES <br />Irrigation Consultant: Scale: NONE <br />Russell D. Mitchell & Assoclates, Inc. <br />2760 Camino Diablo <br />Stone <br />Marrabcini <br />Patterson <br />Architecture <br />Planning <br />Interior Architecture <br />One Market Plaza <br />Spear Street Tower <br />Suite 400 <br />San Francisco <br />CA 94105 <br />415 227-0100 <br />Architect,AIA <br />Tech. Checked Tech. <br />Coord. Arch. <br />RUTHERFORD & CHEKENE <br />303 Second St. Suite 800 N. <br />San Francisco, CA 94107 <br />Structural Engineer <br />GUTMANN & MacRITCHIE <br />1304 Sutter Street <br />Son Francisco, CA 94109 <br />Mechanical Engineer <br />THE ENGINEERING ENTERPRISE <br />1305 Marino Village Parkway <br />Alameda, CA 94501 <br />Electrical Engineer <br />MPA DESIGN <br />562 Mission Street <br />San Francisco, CA 94105 <br />Landscape Architect <br />Approvals <br />Revisions <br />90c;� RI:VIEW <br />Date <br />23 M2\11Z ()2 <br />Walnut Creek, CA 94596 Project No. Drawing N o_ <br />(510) 939-3985 <br />(510) 932-5671 FAX 53000.09 <br />Date <br />L4nC0 <br />