My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2019_PS-1903001 thru PS-1903500_ - PS-1903156
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2019
>
PS-1903001 thru PS-1903500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2019_PS-1903001 thru PS-1903500_ - PS-1903156
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2024 3:04:04 PM
Creation date
6/14/2024 3:01:02 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-1903156
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2019
Notes2
Guard Rd.; Cotta Rd.; Thornton Rd.
Type - Permit Process
Bell Hole
Address
PO Box 930, Stockton,CA 95201
Application
Pacific Gas & Electric-Stockton
Supplemental fields
Cross Ref
PWP730052
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
E <br />W20-1 <br />ROAD <br />WORK <br />25� <br />N <br />rl <br />2 <br />1-5 SB <br />1-5 NB <br />3 <br />W2200-1 <br />P \` <br />ROAD <br />WORK <br />500' a <br />1-5 NB OFF -RAMP <br />END <br />ROAD WORK <br />250' 500' <br />ryORNrom RD <br />1 W20-4 <br />01 <br />250' <br />W3-4 <br />BE <br />PREPARED <br />TO STOP o <br />0 <br />250' 250' <br />W3-4 <br />BE <br />PREPARED <br />TO STOP o <br />0 <br />F N <br />O <br />O <br />N <br />ED <br />N <br />G20-2 <br />END <br />ROAD WORK <br />N <br />CONTRACTOR NOTES: <br />1, ALL TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE LATEST EDITION OF CALIFORNIA MANUAL OF UNIFORM TRAFFIC <br />CONTROL DEVICES (MUTCO) AND CALTRANS STANDARD PLANS AND SPECIFICATIONS, <br />2, CALTRANS, THE LOCAL FIRE. DEPARTMENT, SHERIFF/POLICE DEPARTMENT, CALIFORNIA HIGHWAY PATROL, LOCAL SCHOOL <br />DISTRICT, TRANSIT SERVICE PROVIDERS AND UNITED STATES POSTAL SERVICE SHALL BE NOTIFIED 72 HOURS IN ADVANCE OF <br />CONSTRUCTION WORK, <br />3, THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE TO EXISTING IMPROVEMENTS RESULTING FROM THE <br />CONTRACTOR'S OPERATION, THIS REPAIR SHALL INCLUDE ALL CONSTRUCTION AND MATERIALS TO RESTORE THE SITE TO EXISTING <br />CONDITIONS, <br />4, EACH ADVANCED WARNING SIGN ON EACH SIDE OF THE ROADWAY SHALL BE EQUIPPED WITH AT LEAST TWO FLAGS, FLASHING <br />BEACONS SHALL BE PLACED AT THE LOCATION INDICATED FOR LANE CLOSURE DURING HOURS OF DARKNESS, <br />A 5. ALL WORKERS SHALL BE EQUIPPED WITH A REFLECTIVE VEST AND HARD HAT. ALL FLAGGERS SHALL ALSO BE EQUIPPED WITH A <br />C28 "STOP/SLOW" PADDLE AND SHALL BE TRAINED IN THE PROPER FUNDAMENTALS OF FLAGGING TRAFFIC, <br />6. NO PARKING SIGNS SHALL BE PLACED 72 HOURS PRIOR TO SETUP. SIGNS SHALL BE POSTED EVERY 20 LINEAR FEET OF OCCUPIED <br />SPACE WITH AT LEAST ONE SIGN AT EACH END OF OCCUPIED SPACE. <br />7. ANY CONFLICTING SIGNS WILL BE COVERED FOR THE LENGTH OF THE JOB, <br />8, CONTRACTOR SHALL MAINTAIN EMERGENCY VEHICLE AND DRIVEWAY ACCESS AT ALL TIMES. <br />9, Y&C TRANSPORTATION CONSULTANTS, INC. ASSUMES NO LIABILITY WHEN CONTRACTOR DOES OWN SET UP OR MAKES CHANGES <br />TO THE ORIGINAL TRAFFIC CONTROL PLAN. <br />10, COUNTY/STATE ENGINEER OR HIS REPRESENTATIVE HAS THE AUTHORITY TO INITIATE FIELD CHANGES TO ASSURE PUBLIC SAFETY, <br />11, CONTRACTOR SHALL PLATE EXCAVATED AREA DURING NONWORKING HOURS, <br />S <br />IL <br />2 <br />L0 <br />Lo <br />40'x 75' <br />STAGING AREA <br />12'x8' <br />EXCAVATION <br />C45 <br />RUMBLE <br />Sa <br />TRIPS <br />5 �I I 6 I 7 I 8I I 9 10 <br />DIST. COUNTY ROUTE POST MILE SHEET TOT <br />NO SHE <br />10 SJ 05 41.65 4 8 <br />1-5 NS ON-RAMP <br />W3-4 C9A (CA) <br />500' BUFFER ' <br />• 100'1APER <br />• ' <br />. 550' TANGENT <br />W20-1 <br />ROAD <br />WORK <br />LEGEND <br />-} <br />=TRAFFIC FLOW DIRECTION <br />= TEMPORARY SIGN STAND <br />• = CHANNELIZER (SPACING PER TABLE 1 ON CALTRANS STD PLAN T9) <br />= PORTABLE FLASHING BEACON <br />III = RUMBLE STRIP (SEE SHEET T13 ON CALTRANS STD PLAN) <br />W20-4 <br />d <br />W20A <br />ROAD <br />WORK <br />AHEAC <br />C45 (CA) <br />RUMBLE <br />STRIPS <br />FA <br />500' <br />G20-2 <br />END <br />ROAD WORK <br />n <br />0 50 100 1° <br />SIGN PANEL SIZE <br />48" X 48" <br />48" X 24" <br />06/03/19 <br />LIST <br />ET N0. 4 OF 16 SHEE' <br />74015658 0 <br />I 1 O 0 INCH <br />E <br />C <br />^ ev u <br />um I �� <br />R-1104 <br />LOCATION B <br />L-196, L-1968-7, L-1968-1 <br />TRAFFIC CONTROL PLAN <br />SAN JOAQUIN COUNTY, CALIFORNIA <br />PACIFIC GAS AND ELECTRIC COMPANY <br />SAN RAMON, CALIFORNIA <br />suPv <br />DSGN TK <br />TK <br />TK <br />OWN <br />TK <br />0 <br />00/93/19 <br />ISSUED FON PERMIT <br />74015050 <br />TK <br />7K <br />EO <br />OK <br />EC <br />0. <br />DATE <br />DESCRIPTION <br />R E V I S I O N S <br />GM/SPEC <br />OWN <br />CHKO <br />SUPV <br />APVD BY <br />EC <br />DATE 06/03/19 <br />SCALES <br />SAS SHOWN <br />4 <br />5 <br />6 <br />7 <br />84 <br />1 5 4 9 3 <br />2 <br />06/03/19 <br />LIST <br />ET N0. 4 OF 16 SHEE' <br />74015658 0 <br />I 1 O 0 INCH <br />E <br />C <br />
The URL can be used to link to this page
Your browser does not support the video tag.