1 2 E 3 4 5 °1 6 7 °18 9 10 <br />E <br />AAAAAAAAAE <br />DIRECT BURIAL COATING SELECTIONS <br />MAIN LINE COATING <br />FBE <br />(E-35.4) <br />MINOR REPAIRS <br />LIQUID EPDXY (E-35.3) <br />TIE-IN WELDS <br />LIQUID EPDXY (E-35.1) <br />GIRTH WELDS <br />LIQUID EPDXY (E-35.1) <br />BUTT WELDED FITTINGS <br />LIQUID EPDXY (E-35.1) <br />VALVE ASSEMBLIES <br />LIQUID EPDXY (E-35.7), WAX TAPE (E-35.7) <br />SHORT SEGMENTS OF PIPE <br />LIQUID EPDXY (E-35.1) <br />AIR -TO -SOIL TRANSITIONS <br />LIQUID EPDXY /PSX700 (E-35.8) <br />PRESSURE CONTROL FITTINGS <br />LIQUID EPDXY <br />(E-35.7), <br />WAX TAPE <br />(E-35.7) <br />TIE-INS/COATING TRANSITIONS1 <br />LIQUID EPDXY <br />(E-35.3) <br />BORED COATING SELECTIONS <br />MAIN LINE COATING <br />ARO APPLIED OVER FBE (E-35.4) <br />MINOR REPAIRS <br />LIQUID EPDXIES (E-35.2) <br />TIE-IN WELDS <br />LIQUID EPDXIES (E-35.2) <br />NOTES: <br />1) REFERENCE CONSTRUCTION NOTE 10, COATING REQUIREMENTS. <br />LEGEND: DET/Al L LEGEND: <br />GT— GAS TRANSMISSION LINE (PROPOSED) ----x-- FENCE GAS LINE MARKER (OTHER) QkQ WATER VALVE -------- PROPOSED GAS TRANSMISSION LINE <br />—GT(T)— GAS TRANSMISSION LINE (TO BE TESTED) "rWOALLTYPE — -- <br />INSULATION JOINT © CABLE TV BOX -- <br />—GT— GAS TRANSMISSION LINE (EXISTING) WALL =____ EXISTING GAS TRANSMISSION LINE <br />BARRIER ® PRESSURE CONTROL FITTING TELECOMM BOX <br />—GD— GAS DISTRIBUTION LINE (EXISTING) —�� —_ _---_ TEMPORARY GAS TRANSMISSION LINE <br />— GS — GAS SERVICE LINE (EXISTING) `— TEMPORARY BARRIER (TYPE K) © GAS BOX ®T TELECOMM VAULT (OWNED BY PG&E) E <br />- - - GT - - - GAS TRANSMISSION LINE (RETIRED)"- GUARD RAIL © GAS HIGH PRESSURE REGULATOR Q STREET LIGHT BOX — TEMPORARY GAS TRANSMISSION LINE <br />- - GD - - - GAS DISTRIBUTION LINE (RETIRED) ..._.A. -...-A-"... TOE OF SLOPE (OWNED BY OTHERS) <br />AA PEATOP OF SLOPE 0 GAS METER TREE <br />.._.._. _. ti_.. .._.._.._.._'-- <br />GS EPA OWNER GAS SERVICE LINE (RETIRED) RETIRED GAS TRANSMISSION LINE <br />r EP D® GAS DISTRICT REGULATOR (A) ANODE <br />-•�•-••-••-•• FOREIGN GAS LINE EDGE OF PAVEMENT . _ _. _ _ _ _ _ _ _ GAS TRANSMISSION LINE <br />FC © PG&E GAS MANHOLE QA DEEPWELLANODE """"'"" (TO BE REMOVED) <br />— JT — JOINTTRENCH k FACE OF CURBCOMPUTER AUTOMATED <br />— ET — ELECTRIC TRANSMISSION LINE BW © GAS VAULT CATS TESTSTATION CUT LINE (TO BE REMOVED) <br />ELECTRIC DISTRIBUTION LINE BACK OF WALK e GAS VENT C CTS AC COUPON TEST STATION <br />----- - - - - - <br />— ES — ELECTRIC SERVICE LINE � GAS VALVE CTS COUPON TEST STATION EXISTING GAS DISTRIBUTION LINE <br />_ __ PEA ___ DASHED PAVEMENT MARKINGS <br />— ETOH — ELECTRIC TRANSMISSION OVERHEAD UNPAVED ROAD - - - - - PROPOSED GAS DISTRIBUTION LINE <br />—EDOH— ELECTRIC DISTRIBUTION OVERHEAD <br />T.l:)..: RAILROAD PG&E ELECTRIC MANHOLE ETS ELECTROLYSIS TEST STATION <br />— T — TELEPHONE LINE ELECTRIC VAULT M POLE -MOUNTED RECTIFIER TOP OF GRADE <br />— FO — FIBER OPTIC LINE ACCESS ROAD PAPUTILITY POLE (ELECTRIC) DCIM DCI MITIGATION CABINET GAS VALVE <br />D — TV — CABLE TV LINE LAYDOWN /STAGING/ UTILITY POLE (OTHER) POTHOLE <br />— SD — STORM DRAIN LINE __ CONSTRUCTION IMPACTAREA PIPE END CUT (SIDE) D <br />— SS — SEWER LINE � JOINT POLE CITY/COUNTY MONUMENT <br />EXCAVATION / BELL HOLE PIPE END CUT <br />MONUMENT, SEE DESCRIPTION <br />—W— WATER LINE •A'`` � EXISTING ELECTRIC TOWER FLOW <br />-- UNK UNKNOWN UTILITIES O SAFETY ZONE LIMITS SURVEY CONTROL POINT FLOW ARROW <br />STORM DRAIN INLET <br />C -=--D CASING CENTERLINE ® TIE-IN WELD <br />PROPERTY BOUNDARY ENVIRONMENTALLY UTILITY MANHOLE <br />LA SENSITIVE AREAS z5PAPPAPEA MATERIAL OF RECORD ASSET <br />— — — - PG&E EASEMENT ® WATER METER <br />-- — - TEMPORARY EASEMENT 16 BILL OF MATERIALS ASSET <br />f R/W FOREIGN RIGHT-OF-WAY <br />INSTALLATION TESTED OR INSPECTED AND <br />NOTED ON DRAWING. -' -' - - - CALTRANS RIGHT-OF-WAY <br />ALL CORROSION LEVELS SATISFACTORY PER <br />PG&E GAS UTILITY STANDARD TD -41815. <br />MLDAPE 1AAA o 0 <br />APAP <br />C QUALIFIED EMPLOYEE DATE Acronym Definition Acronym Definition Acronym Definition Acronym Definition Acronym Definition C <br />CORROSION MECHANIC'S SIGNATURE IS (E) Existing DEG Degree HFW High Frequency Weld PKWY Parkway TEMP Temporary <br />REQUIRED WHEN A CPA BOUNDARY IS (P) Proposed DET Detail HPR High Pressure Regulator PL Plastic TG Top of Grade <br />WITHIN THE SCOPE OFTHE PROJECT, AB Aggregate Base DFM Distribution Feeder Main HWY Highway PLC Pregrammagle Logic Controllers TT Top Tap <br />ABN Abandon DI Drainage Inlet ID Inside Diameter PRUPF Procedure forthe Resolution of TSP Transmission System Planning <br />AC Asphalt Concrete DIA Diameter ILI In -Line Inspection Unknown Pipeline Features TYP Typical <br />API American Petroleum Institute DIST Distribution INV Invert PSI Pounds per Square Inch UG Underground <br />APN Assessor's Parcel Number DPV Damage Prevention Volume IRR Irrigation PV Plug Valve USA Underground Service Alert <br />APPROX Approximate DR Distribution Regulator JN Job Number PVMT Pavement UT Ultra -Sonic Test <br />AVE Avenue DREG District Regulator JP Joint Pole QTY Quantity V Valve <br />ARC Abrasion Resistant Coating DSAW Double Submerged Arc -Welded JT Joint Trench R Radius VIF Verify in Field <br />ASME American Society of Mechanical Engineers DWA Deep Well Anode L Line Number RCP Reinforced Concrete Pipe VOL Volume <br />ASTM American Society for Testing Materials DWY Driveway LAT Latitude RD Road W Water <br />BBCL Bell Bell Chill Ring E East LN Lane RDWY Roadway WT Wall Thickness <br />BC Begin Curve EASE Easement LNG Liquid Natural Gas REG Regulator WV Water Valve <br />BD Blowdown EC End Curve LOC Location REL Relocate W/ With <br />BEG Begin . EL Elbow LONG Longitude REPL Replace W/0 Without <br />BKF Backfill ELECT Electric LT Left REV Revision WP Work Procedure <br />BLDG Building ELEV Elevation M Monitor RR Railroad <br />BLVD Boulevard EM Electronic Marker MAOP Maximum Allowable Operating Pressure RT Right <br />BM Bench Mark EMS Engineering Material Specification MAX Maximum RTE Route <br />B BMP Best Management Practice ENGR Engineer MH Manhole R/W Right of Way B <br />BOM Bill of Materials EP Edge of Pavement MIN Minimum S South <br />BR Bridge EQ Equation MISC Miscellaneous SAWH Submerged Arc -Welded Helical <br />BTU British Thermal Units ERW Electric Resistance Welded MLV Main Line Valve SAWL Submerged Arc -Welded Longitudinal <br />BV Ball Valve ESA Environmentally Sensitive Area MOI Method of Installation SCADA Supervisory Control and Data Acquisition <br />BW Back of Walk EATS Electrolysis Test Station MON Monument SD Storm Drain <br />CATS Computer Automated Test Station ETW Edge of Traveled Way MOP Maximum Operating Pressure SG Subgrade <br />CCV Corrosion Control Volume F Filter MP Mile Point SHAT Sheet PAP <br />Cl Cast Iron F & C Frame and Cover MSP Maximum Stopping Pressure SMLS Seamless <br />CL Centerline FBE Fusion Bonded Epoxy MTR Meter SMYS Specified Minimum Yield Strength & <br />CMP Corrugated Metal Pipe FC Face of Curb MW Working Monitor SPEC Specification <br />CNG Compressed Natural Gas FDP Future Design Pressure MWP Maximum Working Pressure SS Sanitary Sewer <br />CO County FG Finished Grade N North SSAW Single Submerged Arc -Welded GASTRANSMISSION m <br />CONC Concrete FH Fire Hydrant NDE Non -Destructive Examination ST Street ESTIMATING & DESIGN <br />COND Conduit FIG Figure NOP Normal Operating Pressure STA Station <br />CP Cathodic Protection FL Flow Line NPC Non-Protected/Native Coupon SAID Standard ISSUED FOR <br />CPT Catch Point FLG Flange NTS Not to Scale STL Steel <br />CROP Conditional Reduction of Pressure FWY Freeway OD Outside Pipe Diameter STPR Strength Test Pressure Report PERMITTING APE <br />CTS Coupon Test Station GS Natural Gas Service OG Original Ground T Tied (Connected to System) <br />CU Copper GS&S Gas Standards and Specifications OH Overhead TCE Temporary Construction Easement ONLY <br />CULV Culvert GV Gate Valve P Pipeline TCP Traffic Control Plan <br />D Depth GW Natural Gas Well P/L Property Line TD Technical Document <br />A DE Dead End H Horizontal PC Point of Curvature TDW T. D, Williamson PACIFIC GAS AND A E <br />DCUST Distribution Customer HDD Horizontal Directional Drill PCF Pressure Control Fitting TEL Telephone ELECTRIC COMPANY <br />PEEP <br />WARNING: PIPELINE - LEGEND & STAMPS BILLOFMATL SHEETI4 <br />THIS DOCUMENT CONTAINS', n�1 L-1960 L-1968-7, L-1968-1 <br />CONFIDENTIAL, PROPRIETARY <br />INFORMATION THAT IS THE SOLE f RETIRES MILES JOBID <br />PROPERTY OF PACIFIC GAS AND R-1104 APE <br />ELECTRIC COMPANY AND IS B 5-10-19 ISSUED FOR PERMITTING 74015658 RWM KJT6 N3RD LODI, SAN JOAQUIN COUNTY <br />AP <br />INTENDED FOR USE ONLY BY SHEET NO. 3 OF 14 SHEETS <br />AUTHORIZED PACIFICGASAND REV. DATE DESCRIPTION ORDER DWN ACE ENG A 2-28-19 ISSUED FOR 30% REVIEW 74015658 RWM pT6 N1RD PACIFIC GAS AND ELECTRIC COMPANY GAS TRANSMISSION&DISTRIBUTION R <br />ELECTRICCOMPANY EMPLOYEES RnowwhaYs below. f ENG APVD 74015658 L7 <br />AND ITS AGENTS. CaIIII8I0i890U d1g. ® - <br />® PG&E CO, REVISIONS p SAN FRANCISCO, CALIFORNIA <br />1 2 0l 3 4 S S( 6 7 218 74015658,M34.&dgn 4 9 3 18•MAY•201906WAM 10 0 NCH <br />