My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2018_PS-1802501 thru PS-1803000_ - PS-1802794 Rider #1 1-16-20
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2018
>
PS-1802501 thru PS-1803000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2018_PS-1802501 thru PS-1803000_ - PS-1802794 Rider #1 1-16-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2024 10:50:18 AM
Creation date
6/19/2024 10:48:54 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-1802794
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2018
Notes2
S/S of Collier Rd. 1500' W/O St. Rte. 99
Type - Permit Process
Collier Road Improvements
Address
847 N. Cluff Ave., STE B1, Lodi,CA 95240
Application
Lenz Lantz Development, LLC
Supplemental fields
Cross Ref
PWP790107
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
12/26/2019 ATC Hazards by Location <br />OTC Hazards by Location <br />Search Information Nw sacraments <br />0 <br />Address: 3222 Collier Rd E, Acampo, CA 95220, USA Elk 54 ft <br />Vacaville <br />Coordinates: 38.2167321 -121.27803599999999 <br />Elevation: 54 ft <br />Timestamp: 2019-12-26T16:44:09.893Z <br />ConcordStockton Sonora <br />Hazard Type: Seismic O O <br />Tuo! <br />Reference ASCE7A0– <br />I ig a Manteca Ma cinep ortaima error: <br />Document: — 0 p <br />Risk Category: II <br />Site Class: D <br />Basic Parameters <br />Name Value Description <br />SS 0.689 MCER ground motion (period=0.2s) <br />S1 0.289 MCER ground motion (period=1.0s) <br />SMS 0.86 Site -modified spectral acceleration value <br />SM1 <br />0.526 <br />Description <br />Site -modified spectral acceleration <br />value <br />SDS <br />0.574 <br />1.249 <br />Numeric seismic design value at 0.2s <br />SA <br />SDI <br />0.351 <br />CRS <br />Numeric seismic design value at 1.0s <br />SA <br />Additional Information <br />Name <br />Value <br />Description <br />SDC <br />D <br />Seismic design category <br />Fa <br />1.249 <br />Site amplification factor at 0.2s <br />F„ <br />1.823 <br />Site amplification factor at 1 O <br />CRS <br />1.114 <br />Coefficient of risk (0.2s) <br />CR1 <br />1.145 <br />Coefficient of risk (1.0s) <br />PGA <br />0.234 <br />MCEG peak ground acceleration <br />FPGA <br />1.332 <br />Site amplification factor at PGA <br />PGAM <br />0.311 <br />Site modified peak ground acceleration <br />TL <br />12 <br />Long -period transition period (s) <br />haps:/(hazards.atcouncll.orgl#/seismic71at=38.216732&Ing=-121.276035999999998address=3222 Collier Rd E°%2C Acampo°,62C CA 95220°,62C USA 1 /2 <br />12/26/2019 ATC Hazards by Location <br />SsRT 0.689 Probabilistic risk -targeted ground motion (0.2s) <br />SsUH 0.618 Factored unlform-hazard spectral acceleration (2% probability of <br />exceedance in 50 years) <br />SsD 1.5 Factored deterministic acceleration value (0.2s) <br />S 1 RT 0.289 Probabilistic risk -targeted ground motion (1.0s) <br />S1 UH 0.252 Factored uniform -hazard spectral acceleration (2% probability of <br />exceedance in 50 years) <br />S1 D 0.6 Factored deterministic acceleration value (1.0s) <br />PGAd 0.5 Factored deterministic acceleration value (PGA) <br />The results indicated here DO NOT reflect any state orlocal amendments to the values or any delineation lines made during fhe building <br />code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Judsdiction before <br />proceeding with design. <br />Disclaimer <br />Hazard loads are provided by the U.S. Geological Survey Seismic Design Web Services. <br />While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility <br />or liab(lity for its accuracy. The material presented in the report should not be used or relied upon for any specific application without <br />competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does <br />not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge <br />in the field of practice, nor to substitute for the standard of care required of such professionals In interpreting and applying the results of the <br />report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of <br />this website does not Imply approval by the governing building code bodies responsible for building code approval and interpretation for the <br />building site described by latitude/longitude location in the report. <br />https:/lhazards.atcouncil.orgf#/selsmlc71at=38.21673281ng=-121.27603599999999&address=3222 Collier Rd E%2C Acampo%2C CA 95220°h2C USA 2/2 <br />Contractor: <br />LENZI 50LAP <br />LENZI INCORPORATED <br />CSLB # 1007527 <br />847 N, CLUFF AVE, SUITE B 1 <br />ODI, CA 95240 <br />(209) 224-5950 <br />www, lenzlcon5tructlona nd5olar, corn <br />Project: <br />SOLAR LIGHT POLE <br />3222 COLLIER RD, EAST <br />ACAMPO CA 95220 <br />Project Details: <br />PV ARRAY: 550 W <br />BATTERY BANK: 224 Ah, 5.4 kW <br />REVISIONS <br />DESCRIPTION <br />DATE <br />REV <br />PERMIT SET <br />12/31/2019 <br />A <br />Sheet Title: <br />STRUCTURAL <br />CALCULATIONS 3 <br />Sheet Number: <br />56.0 <br />Sheet Size: <br />ANSI B- 17" x I I" <br />DESIGN DRAFTING BY: <br />AARON CARDWELL// Of%� <br />j <br />SepiSolar. <br />POWER BY DESIGN <br />Reviewed Approved by: <br />CM <br />
The URL can be used to link to this page
Your browser does not support the video tag.