My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2018_PS-1802501 thru PS-1803000_ - PS-1802794 Rider #1 1-16-20
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2018
>
PS-1802501 thru PS-1803000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2018_PS-1802501 thru PS-1803000_ - PS-1802794 Rider #1 1-16-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2024 10:50:18 AM
Creation date
6/19/2024 10:48:54 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-1802794
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2018
Notes2
S/S of Collier Rd. 1500' W/O St. Rte. 99
Type - Permit Process
Collier Road Improvements
Address
847 N. Cluff Ave., STE B1, Lodi,CA 95240
Application
Lenz Lantz Development, LLC
Supplemental fields
Cross Ref
PWP790107
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
stru <br />ures <br />AOstructures Inc, <br />PO Box 413 <br />Carnelian Bay, CA 96140 <br />916.541.8586 <br />www,AOstru ctu res. com <br />Input Variables <br />Wind Calculations <br />Per ASCE 740 MWFRS <br />Wind Speed <br />110 mph <br />Exposure Category <br />C <br />Roof Shape <br />Monoslope <br />Array Till <br />20 degrees <br />Mean Roof Height <br />15 ft <br />Wind Flow <br />Clear <br />Design Wind Pressure Calculations <br />Wind Pressure P=qh*(G*Cp) <br />qh = 0.00256 * Kz " Kzt" Kd * V^2 <br />Kz (Exposure Coefficient) = 0.85 <br />Kzt (topographic factor) = 1 <br />Kd (Wind Directionality Factor) = 0.85 <br />V (Design Wind Speed) = 110 mph <br />Risk Category = II <br />qh = 22.38 <br />(Table 30.3-1) <br />(Fig. 26.8-1) <br />(Table 26.6-1) <br />(Fig. 26.5-1A) <br />(Table 1.5-1) <br />MWFRS Uplift Calculations - WD = 0 (From ASCE 7-10) <br />Cp (Fig. 27.4-4) G GCp Pressure Frame X pif Loading <br />A Cnw -1.30 0.85 -1.11 -24.7 psf 65f <br />-160.7 pif <br />B Cnw -2.23 0.85 -1.90 -42.5 psf 6.5 ft -276.2 plf <br />A Cnl -1.50 0.85 -1.28 -28.5 psf 6.5 ft -185.5 pif <br />B Cnl -0.20 0.85 -0.17 -3.8 psf 6.5 ft -24.7 plf <br />MWFRS Down Calculations - WD =180 (From ASCE 7-10) <br />Cp (Fig. 27.4-4) G GCp Pressure Frame X plf Loading <br />A Cnw 1.57 0.85 1.33 29.8 psf 6.5 ft 193.7 pif <br />B Cnw 2.07 0.85 1.76 39.3 psf 6.5 ft 255.5 plf <br />A Cnl 1.73 0.85 1.47 33.0 psf 6.5 ft 214.3 plf <br />B Cnl 0.67 0.85 0.57 12.7 psf 6.5 ft 82.4 plf <br />Magnolia Solar Light - Calcs 2 <br />stru <br />u res <br />LATERAL LOADING <br />SEISMIC ANCHORAGE OF MECHANICAL EQUIPMENT <br />Fp of Mounted Equipment) <br />Per ASCE 7-10, Chapter 13 <br />Design Values <br />Sds = 1.54 <br />S1 = 0.81 <br />Importance Factor = 1.00 <br />Seismic Design Category = E <br />Component Response Modification Factor (Rp) = 2.5 <br />Component Amplification Factor (ap) = 1.0 <br />Component Importance Factor (Ip) = 1.0 <br />7Jh = 1.00 <br />Equipment Weight (Wp) = 0.50 k <br />Seismic Design Force <br />Fp = 0.4 * ap * SDS " Wp (1 + 2z/h) <br />(RpIlp) <br />0.37 k Governs <br />S2o = 1 <br />t:2o Fp = 0.37 k <br />0.30 k <br />(Tabe 111.5-1) <br />(i able 11.6-1) <br />(Table 13.6-1) <br />(Table 13.6-1) <br />AOstructures Inc. <br />PO Box 413 <br />Carnelian Bay, CA 96140 <br />916.541.8586 <br />www.AOstructu res.com <br />LENZI SOLAR <br />LENZI INCORPORATED <br />B#1007527 <br />847 N, CLUFF AVE, SUITE B I <br />LODI, CA 95240 <br />9)224-5950 <br />www.lenzlconstructlonandsolar,com <br />SOLAR LIGHT POLE <br />3222 COLLIER RD, EAST <br />ACAMPO CA 95220 <br />Project Details: <br />PV ARRAY: 550 W <br />BATTERY BANK: 224 Ah, 5.4 kW <br />REVISIONS <br />DESCRIPTION DATE REV <br />PERMIT SET 12/31/2019 A <br />Sheet Title: <br />STf�U CTU IAL <br />CALCULATIONS 2 <br />Sheet Number: <br />55.0 <br />Sheet Slze: <br />ANSI B- 17 X I I" <br />DRAFTING BY: <br />DN CARDWELLG� <br />7 <br />SepiSOlar. <br />POWER 1Y DESIGN <br />Reviewed 4 Apfirovedd <br />by: <br />
The URL can be used to link to this page