0
<br />R
<br />INFILTRATION h.
<br />a. MANUFACTURED DOORS AND WINDOWS SHALL HAVE AIR INFILTRATION RATES CERTIFIED
<br />BY MANUFACTURER AS NOT EXCEEDING THOSE SHOWN IN TABLE 2-53J OF THE L
<br />CALIFORNIA ADMINISTRATIVE CODE. LABELS INDICATING TESTING AND COMPLIANCE WITH
<br />INDUSTRY STANDARDS, APPROVED BY THE EXECUTIVE DIRECTOR, ARE ADEQUATE
<br />DEMONSTRATION AND CERTIFICATION OF COMPLIANCE WITH THIS REQUIREMENT. i.
<br />b. FOR SITE—CONSTRUCTED DOORS, WINDOWS, EXTERIOR JOINTS, AND OPENING IN THE
<br />BUILDING ENVELOPE THAT ARE OBSERVABLE SOURCES OF AIR LEAKAGE MUST BE k.
<br />CAULKED, WEATHER—STRIPPED, GASKETED, OR OTHERWISE SEALED. (EXCEPTIONS ARE
<br />GIVEN IN SECTION 2-5317 OF THE CALIFORNIA ADMINISTRATIVE CODE).
<br />C. DOORS AND WINDOWS BETWEEN CONDITIONED AND UNCONDITIONED SPACES, SUCH AS
<br />GARAGES AND CLOSETS FOR CENTRAL FORCED AIR GAS FURNACES USING OUTSIDE AIR
<br />FOR COMBUSTION, SHALL BE DESIGNED TO LIMIT AIR LEAKAGES INTO OR FROM THE
<br />BUILDING ENVELOPE.
<br />d. HVAC DUCTS SHALL BE CONSTRUCTED, INSTALLED, SEALED AND INSULATED IN
<br />ACCORDANCE WITH CHAPTER 4-10 OF THE 1988 CALIFORNIA STATE MECHANICAL
<br />CODE.
<br />LIGHTING SYSTEM
<br />EACH AREA ENCLOSED BY CEILING—HEIGHT PARTITIONS SHALL HAVE INDEPENDENT
<br />CONTROL OF THE LIGHTING WITHIN THAT AREA.
<br />EACH AREA ENCLOSED BY CEILING—HEIGHT PARTITIONS SHALL HAVE AT LEAST ONE
<br />READILY ACCESSIBLE MANUALLY OPERATED SWITCHING DEVICE TO CONTROL LIGHTING
<br />WITHIN THE AREA. FOR LIGHTING CONTROLS, "READILY ACCESSIBLE" MEANS LOCATED
<br />SO THAT A PERSON USING THE DEVICE CAN SEE THE CONTROLLED LIGHTS OR THE
<br />AREA BEING LIT. SWITCHING DEVICE IN ADDITION TO, BUT NOT INSTEAD OF, THE
<br />REQUIRED DEVICES SHALL ALSO BE PERMITTED.
<br />THE GENERAL LIGHTING OF ANY ENCLOSED AREA 100 SQ.FT. OR LARGER IN WHICH
<br />THE CONNECTED LIGHTING LOAD EXCEED THE 1.0 WATT/SQ.FT. FOR THE AREA, SHALL
<br />BE CONTROLLED SO THAT LIGHT MAY BE REDUCED BY AT LEAST 1/2 WHILE
<br />MAINTAINING A REASONABLE UNIFORM LEVEL OF ILLUMINATION THROUGHOUT THE AREA.
<br />IN ALL AREAS WHERE EFFECTIVE USE MAY BE MADE OF NATURAL LIGHT, LIGHTING
<br />CIRCUITRY SHALL BE ARRANGED SO THAT UNITS, IN ALL PORTIONS OF THE AREA
<br />WHERE NATURAL LIGHT IS AVAILABLE AT THE SAME TIME, ARE SWITCHED
<br />INDEPENDENTLY OF THE REMAINDER OF THE AREA.
<br />DAYLIGHT CONTROL SHALL BE CAPABLE OF REDUCING THE GENERAL LIGHTING OF THE
<br />CONTROLLED AREA BY AT LEAST 1/2 WHILE MAINTAINING A UNIFORM LEVEL OF
<br />ILLUMINANCE THROUGHOUT THE AREA.
<br />IF THE CONTROL IS A DIMMER, THE CONTROL SHALL HAVE THE CAPABILITY, AS
<br />CERTIFIED BY THE MANUFACTURER, OF PROVIDING ELECTRICAL OUTPUTS TO THE LAMP
<br />FOR FLICKER FREE OPERATION THROUGHOUT THE DIMMING RANGE AND WITHOUT
<br />CAUSING PREMATURE FAILURE.
<br />THE CONTROLS SHALL INCORPORATE TIME DELAY CIRCUITS TO PREVENT UNDESIRABLE
<br />CYCLING OF LIGHT LEVEL CHANGES.
<br />IF THE CONTROL USES STEP SWITCHING WITH SEPARATE ON AND OFF SETTINGS FOR
<br />THE STEPS, ADJUSTMENT SHALL ALLOW SUFFICIENT SEPARATION OF ON AND OFF
<br />POINTS TO PREVENT CYCLING.
<br />EACH PHOTOCELL SENSOR SHALL BE A LIGHT DIFFUSER TYPE AND SHALL NOT HAVE A
<br />MECHANICAL SLIDE COVER OR OTHER DEVICE THAT WOULD PERMIT EASY
<br />UNAUTHORIZED DISABLING OF THE CONTROL.
<br />THE MANUFACTURER SHALL PROVIDE STEP—BY—STEP INSTRUCTIONS FOR THE
<br />INSTALLATION AND START—UP CALIBRATION TO DESIGN LIGHTING LEVELS.
<br />IF DAYLIGHTING CONTROLS, LUMEN MAINTENANCE CONTROLS, OR OCCUPANT—SENSING
<br />DEVICES ARE INSTALLED TO COMPLY WITH SECT. 2-5341(b) OR 2-5342(d), THEY
<br />SHALL BE VISIBLY OR AUDIBLY WARN THE OCCUPANTS OR BUILDING OPERATORS WHEN
<br />THEY HAVE FAILED OR MALFUNCTIONED.
<br />i
<br />Certificate _ of Com H a n c e Pari 1 of 2 Performance Re uirements C F -1 B
<br />For Enforcement Aqency Use Only
<br />ProjecFTiffe -Dafe oT-CerflfFcafe—
<br />AN "'•o tai l p F �� i r � FL F,'v -rA
<br />Project Architect/Engineer
<br />PioIec1 Location
<br />City Town
<br />Documentation Author%firm Telephone
<br />fi-
<br />Principal Designer. The proposed building will be in substantial
<br />compliance with the California Building Energy Efficiency Standards
<br />provided it is built according to the plans and specifications and provided
<br />future Improvements are completed according to the requirements
<br />indicated on this Certificate of Compliance. The plans and specifications
<br />have been prepared to include all significant energy conservation features
<br />required for compliance with the Standards. Building areas that are
<br />unconditioned and/or not subject to the standards are indicated on the
<br />plans.
<br />2; 41 1�3 I --
<br />Plans dated. y Specs. dated
<br />gnT afore Date
<br />Name/Title� -
<br />_Campany
<br />Address
<br />City%St-a-fe ip; - --
<br />�r1453 --1�
<br />Te ephonea ._ L cense fTo.
<br />Owner. The energy conservation features and performance
<br />specifications indicated on this document and on the plans and
<br />specifications shall apply to future alterations, unless compliance is
<br />demonstrated anew and a new Certificate of Compliance is submitted. A
<br />copy of this Certificate will be retained and transmitted to future tenants,
<br />subsequent owners or others with responsibility for making improvements
<br />or modifications to the building. If this certificate is lost, a new Certificate
<br />may be required before a permit is issued for alterations. Unconditioned
<br />areas are indicated on the plans and, if these areas are conditioned in the
<br />future, they must be made to comply with the applicable energy standards
<br />then in effect.
<br />Building Permit Number
<br />Plan Checked By Date
<br />Field Checked By Date
<br />Approved By Date
<br />--
<br />Energy Analyst. The energy performance analysis summarized below
<br />was performed using an approved CEC calculation method, with CEC i
<br />approved fixed and restricted engineering inputs for the applicable climate
<br />zone and occupancy type, and using an appropriate representation of
<br />building zoning and physical configuration. All significant energy
<br />conservation features are listed b ow, qr on an attached supplement.
<br />lig-nafure Date I
<br />NarneJ Iffe
<br />o n
<br />Address I
<br />-Cify%Sfa-fe/ZTp -
<br />Telephone - -
<br />General Reference 1/01 Unconditioned or Multi -tenant shell?.
<br />2 CEC Occupancy Type. . . . . . .
<br />3 UBC Occ. Group/Division.
<br />4 Climate Zone. . . . . . . . . . .
<br />5 Conditioned Floor Area . . . .
<br />6 Unconditioned Floor Area. % -
<br />— a1
<br />7 Budget Table (fr. Standards)
<br />8 All. Energy Budget (WS -1A) -','�1 kBtu/sf-yr
<br />9 Calc. Method CEC Code/Date�-
<br />10 Multiplier . . . . . . . . . . . . . _ =%-- 7 '
<br />11 Calculated Energy Use. . . . . kBtu/sf-yr i
<br />INSULATION REQUIREMENTS
<br />yo / _--v -t. . . .
<br />a.
<br />INSULATION SHALL BE INSTALLED TO THE MINIMUM "R" VALUES INDICATED IN FIGURE 1.
<br />a.
<br />Average Exterior Floor Rt.
<br />INSULATING MATERIAL OF THE TYPES LISTED IN TABLE 2-53D OF THE CALIFORNIA
<br />Signature - Date
<br />rF,S1
<br />ADMINISTRATIVE CODE SHALL BE INSTALLED ONLY IF IT HAS BEEN CERTIFIED BY THE
<br />b.
<br />-.-- - h-F-sf/Btu j
<br />MANUFACTURER TO COMPLY WITH THE CALIFORNIA QUALITY STANDARDS FOR
<br />15
<br />Glazing Area in Wall . . . . .
<br />INSULATING MATERIAL.
<br />_'t`1 G (-) I iL _ __- _._._..._ __
<br />Company
<br />b.
<br />ALL INSULATING MATERIAL SHALL BE INSTALLED IN COMPLIANCE WITH THE
<br />_ rt-
<br />I�I0 A HZ, -1
<br />FLAME—SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF SECTION 1712 AND
<br />Glazing Area in Roof. . . . . .
<br />-__-_ sf
<br />1713 OF THE 1988 UBC.
<br />18
<br />C.
<br />APPLICATION OF UREA FORMALDEHYDE FOAM INSULATION IS RESTRICTED TO EXTERIOR
<br />C.
<br />Telephone Cal. License No.
<br />SIDEWALLS. A FOUR MILL THICKNESS PLASTIC POLYETHYLENE VAPOR BARRIER OR
<br />Enforcement Agency Date
<br />i�'lyjSfa a ip
<br />EQUIVALENT PLASTIC SHEETING VAPOR BARRIER SHALL BE INSTALLED TO SEPARATE
<br />1
<br />Enforcement Agency.The proposed building, and future alterations will
<br />THE UREA FOAM INSULATION FROM THE INTERIOR SPACE.
<br />Allowed Whole Building LPD.
<br />d.
<br />IF EXTERNAL INSULATION IS APPLIED TO HEATING AND COOLING SYSTEM DUCTS, IT
<br />d.
<br />Allowed Common Areas LPD.
<br />SHALL CONFORM TO THE THERMAL RESISTANCE REQUIREMENTS OF SECT.1005 OF THE
<br />future alterations meet the requirements indicated on this Certificate and
<br />21
<br />1988 UMC.
<br />-watts/sf I
<br />e.
<br />IF EXTERNAL INSULATION IS APPLIED TO FIRED WATER HEATERS IT SHALL HAVE A
<br />Package Lighting Reduction
<br />vans/sf
<br />THERMAL RESISTANCE OF AT LEAST R-6.
<br />e.
<br />f.
<br />IF AN UNFIRED HOT WATER STORAGE TANK IS INSTALLED, THE TANK SHALL BE
<br />17
<br />Mechanical Requirements
<br />INSULATED TO A THERMAL RESISTANCE OF AT LEAST R-12.
<br />-STgnafure - Date - -- - -----
<br />g.
<br />PIPING MUST BE INSULATED CONSISTENT WITH THE REQUIREMENTS OF SECTION
<br />f.
<br />Name/Title—
<br />2-5312. PIPING WITHIN PACKAGE HVAC EQUIPMENTS NEED NOT BE INSULATED.
<br />Unit Fan Power
<br />h.
<br />CEILING INSULATION MUST BE INSTALLED FAR ENOUGH TO THE OUTSIDE WALLS TO
<br />26
<br />Rated Cooling Efficiency.
<br />COVER THE TOP PLATE AND ACCESS PANELS.
<br />company - -- - -- - ------
<br />R
<br />INFILTRATION h.
<br />a. MANUFACTURED DOORS AND WINDOWS SHALL HAVE AIR INFILTRATION RATES CERTIFIED
<br />BY MANUFACTURER AS NOT EXCEEDING THOSE SHOWN IN TABLE 2-53J OF THE L
<br />CALIFORNIA ADMINISTRATIVE CODE. LABELS INDICATING TESTING AND COMPLIANCE WITH
<br />INDUSTRY STANDARDS, APPROVED BY THE EXECUTIVE DIRECTOR, ARE ADEQUATE
<br />DEMONSTRATION AND CERTIFICATION OF COMPLIANCE WITH THIS REQUIREMENT. i.
<br />b. FOR SITE—CONSTRUCTED DOORS, WINDOWS, EXTERIOR JOINTS, AND OPENING IN THE
<br />BUILDING ENVELOPE THAT ARE OBSERVABLE SOURCES OF AIR LEAKAGE MUST BE k.
<br />CAULKED, WEATHER—STRIPPED, GASKETED, OR OTHERWISE SEALED. (EXCEPTIONS ARE
<br />GIVEN IN SECTION 2-5317 OF THE CALIFORNIA ADMINISTRATIVE CODE).
<br />C. DOORS AND WINDOWS BETWEEN CONDITIONED AND UNCONDITIONED SPACES, SUCH AS
<br />GARAGES AND CLOSETS FOR CENTRAL FORCED AIR GAS FURNACES USING OUTSIDE AIR
<br />FOR COMBUSTION, SHALL BE DESIGNED TO LIMIT AIR LEAKAGES INTO OR FROM THE
<br />BUILDING ENVELOPE.
<br />d. HVAC DUCTS SHALL BE CONSTRUCTED, INSTALLED, SEALED AND INSULATED IN
<br />ACCORDANCE WITH CHAPTER 4-10 OF THE 1988 CALIFORNIA STATE MECHANICAL
<br />CODE.
<br />LIGHTING SYSTEM
<br />EACH AREA ENCLOSED BY CEILING—HEIGHT PARTITIONS SHALL HAVE INDEPENDENT
<br />CONTROL OF THE LIGHTING WITHIN THAT AREA.
<br />EACH AREA ENCLOSED BY CEILING—HEIGHT PARTITIONS SHALL HAVE AT LEAST ONE
<br />READILY ACCESSIBLE MANUALLY OPERATED SWITCHING DEVICE TO CONTROL LIGHTING
<br />WITHIN THE AREA. FOR LIGHTING CONTROLS, "READILY ACCESSIBLE" MEANS LOCATED
<br />SO THAT A PERSON USING THE DEVICE CAN SEE THE CONTROLLED LIGHTS OR THE
<br />AREA BEING LIT. SWITCHING DEVICE IN ADDITION TO, BUT NOT INSTEAD OF, THE
<br />REQUIRED DEVICES SHALL ALSO BE PERMITTED.
<br />THE GENERAL LIGHTING OF ANY ENCLOSED AREA 100 SQ.FT. OR LARGER IN WHICH
<br />THE CONNECTED LIGHTING LOAD EXCEED THE 1.0 WATT/SQ.FT. FOR THE AREA, SHALL
<br />BE CONTROLLED SO THAT LIGHT MAY BE REDUCED BY AT LEAST 1/2 WHILE
<br />MAINTAINING A REASONABLE UNIFORM LEVEL OF ILLUMINATION THROUGHOUT THE AREA.
<br />IN ALL AREAS WHERE EFFECTIVE USE MAY BE MADE OF NATURAL LIGHT, LIGHTING
<br />CIRCUITRY SHALL BE ARRANGED SO THAT UNITS, IN ALL PORTIONS OF THE AREA
<br />WHERE NATURAL LIGHT IS AVAILABLE AT THE SAME TIME, ARE SWITCHED
<br />INDEPENDENTLY OF THE REMAINDER OF THE AREA.
<br />DAYLIGHT CONTROL SHALL BE CAPABLE OF REDUCING THE GENERAL LIGHTING OF THE
<br />CONTROLLED AREA BY AT LEAST 1/2 WHILE MAINTAINING A UNIFORM LEVEL OF
<br />ILLUMINANCE THROUGHOUT THE AREA.
<br />IF THE CONTROL IS A DIMMER, THE CONTROL SHALL HAVE THE CAPABILITY, AS
<br />CERTIFIED BY THE MANUFACTURER, OF PROVIDING ELECTRICAL OUTPUTS TO THE LAMP
<br />FOR FLICKER FREE OPERATION THROUGHOUT THE DIMMING RANGE AND WITHOUT
<br />CAUSING PREMATURE FAILURE.
<br />THE CONTROLS SHALL INCORPORATE TIME DELAY CIRCUITS TO PREVENT UNDESIRABLE
<br />CYCLING OF LIGHT LEVEL CHANGES.
<br />IF THE CONTROL USES STEP SWITCHING WITH SEPARATE ON AND OFF SETTINGS FOR
<br />THE STEPS, ADJUSTMENT SHALL ALLOW SUFFICIENT SEPARATION OF ON AND OFF
<br />POINTS TO PREVENT CYCLING.
<br />EACH PHOTOCELL SENSOR SHALL BE A LIGHT DIFFUSER TYPE AND SHALL NOT HAVE A
<br />MECHANICAL SLIDE COVER OR OTHER DEVICE THAT WOULD PERMIT EASY
<br />UNAUTHORIZED DISABLING OF THE CONTROL.
<br />THE MANUFACTURER SHALL PROVIDE STEP—BY—STEP INSTRUCTIONS FOR THE
<br />INSTALLATION AND START—UP CALIBRATION TO DESIGN LIGHTING LEVELS.
<br />IF DAYLIGHTING CONTROLS, LUMEN MAINTENANCE CONTROLS, OR OCCUPANT—SENSING
<br />DEVICES ARE INSTALLED TO COMPLY WITH SECT. 2-5341(b) OR 2-5342(d), THEY
<br />SHALL BE VISIBLY OR AUDIBLY WARN THE OCCUPANTS OR BUILDING OPERATORS WHEN
<br />THEY HAVE FAILED OR MALFUNCTIONED.
<br />i
<br />Certificate _ of Com H a n c e Pari 1 of 2 Performance Re uirements C F -1 B
<br />For Enforcement Aqency Use Only
<br />ProjecFTiffe -Dafe oT-CerflfFcafe—
<br />AN "'•o tai l p F �� i r � FL F,'v -rA
<br />Project Architect/Engineer
<br />PioIec1 Location
<br />City Town
<br />Documentation Author%firm Telephone
<br />fi-
<br />Principal Designer. The proposed building will be in substantial
<br />compliance with the California Building Energy Efficiency Standards
<br />provided it is built according to the plans and specifications and provided
<br />future Improvements are completed according to the requirements
<br />indicated on this Certificate of Compliance. The plans and specifications
<br />have been prepared to include all significant energy conservation features
<br />required for compliance with the Standards. Building areas that are
<br />unconditioned and/or not subject to the standards are indicated on the
<br />plans.
<br />2; 41 1�3 I --
<br />Plans dated. y Specs. dated
<br />gnT afore Date
<br />Name/Title� -
<br />_Campany
<br />Address
<br />City%St-a-fe ip; - --
<br />�r1453 --1�
<br />Te ephonea ._ L cense fTo.
<br />Owner. The energy conservation features and performance
<br />specifications indicated on this document and on the plans and
<br />specifications shall apply to future alterations, unless compliance is
<br />demonstrated anew and a new Certificate of Compliance is submitted. A
<br />copy of this Certificate will be retained and transmitted to future tenants,
<br />subsequent owners or others with responsibility for making improvements
<br />or modifications to the building. If this certificate is lost, a new Certificate
<br />may be required before a permit is issued for alterations. Unconditioned
<br />areas are indicated on the plans and, if these areas are conditioned in the
<br />future, they must be made to comply with the applicable energy standards
<br />then in effect.
<br />Building Permit Number
<br />Plan Checked By Date
<br />Field Checked By Date
<br />Approved By Date
<br />--
<br />Energy Analyst. The energy performance analysis summarized below
<br />was performed using an approved CEC calculation method, with CEC i
<br />approved fixed and restricted engineering inputs for the applicable climate
<br />zone and occupancy type, and using an appropriate representation of
<br />building zoning and physical configuration. All significant energy
<br />conservation features are listed b ow, qr on an attached supplement.
<br />lig-nafure Date I
<br />NarneJ Iffe
<br />o n
<br />Address I
<br />-Cify%Sfa-fe/ZTp -
<br />Telephone - -
<br />General Reference 1/01 Unconditioned or Multi -tenant shell?.
<br />2 CEC Occupancy Type. . . . . . .
<br />3 UBC Occ. Group/Division.
<br />4 Climate Zone. . . . . . . . . . .
<br />5 Conditioned Floor Area . . . .
<br />6 Unconditioned Floor Area. % -
<br />— a1
<br />7 Budget Table (fr. Standards)
<br />8 All. Energy Budget (WS -1A) -','�1 kBtu/sf-yr
<br />9 Calc. Method CEC Code/Date�-
<br />10 Multiplier . . . . . . . . . . . . . _ =%-- 7 '
<br />11 Calculated Energy Use. . . . . kBtu/sf-yr i
<br />HVAC SYSTEMS AND CONTROLS
<br />a. HEAT PUMP (IF ANY) SHALL BE INSTALLED WITH A CONTROL TO PREVENT
<br />SUPPLEMENTARY HEATER OPERATION WHEN THE HEATER LOAD CAN BE MET BY THE
<br />HEAT PUMP ALONE.
<br />b. IF CIRCULATING HOT WATER SYSTEM IS INSTALLED, IT SHALL HAVE A CONTROL
<br />CAPABLE OF AUTOMATICALLY TURNING OFF THE CIRCULATING PUMP(S) WHEN HOT
<br />WATER IS NOT REQUIRED.
<br />C. SERVICE WATER HEATING SYSTEM SHALL BE EQUIPPED WITH AUTOMATIC TEMPERATURE
<br />CONTROLS CAPABLE OF ADJUSTMENT FROM THE LOWEST TO THE HIGHEST ACCEPTABLE
<br />TEMPERATURE SETTING FOR THE INTENDED USE AS LISTED IN TABLE 2, CHAPTER 37
<br />OF THE ASHRAE HANDBOOK AND PRODUCT DIRECTORY, SYSTEM VOLUME.
<br />d. EACH ZONE SHALL BE PROVIDED WITH AT LEAST ONE AUTOMATIC TEMPERATURE
<br />CONTROL DEVICE FOR THE REGULATION OF SPACE TEMPERATURE. EACH FLOOR OF THE
<br />BUILDING WITH CONDITIONED SPACE SHALL CONTAIN AT LEAST ONE ZONE.
<br />e. ZONE TEMPERATURE CONTROLS SHALL BE ABLE TO MAINTAIN SPACE TEMPERATURE SET
<br />POINTS FROM 55 DEG.F. TO 85 DEG.F. TWO OR MORE REPLACEABLE FIXED SET POINT
<br />DEVICES, ONE FOR COOLING AND ONE FOR HEATING, MAY BE USED IN LIEU OF
<br />CONTINUOUSLY ADJUSTABLE SET POINT DEVICES.
<br />f. ZONE TEMPERATURE CONTROLS SHALL BE ABLE TO OPERATE ZONE HEATING AND
<br />COOLING IN SEQUENCE IF BOTH ARE PROVIDED.
<br />9. ZONE TEMPERATURE CONTROL SHALL PROVIDE A TEMPERATURE RANGE ADJUSTABLE UP
<br />TO 10 DEG.F. BETWEEN FULL RANGE HEATING AND FULL RANGE COOLING CAPABILITY.
<br />h. ON MECHANICAL VENTILATION SUPPLY AND EXHAUST SYSTEMS CAPABLE OF MOVING
<br />MORE THAN 5,000 CFM OF AIR, AUTOMATIC DAMPERS INTERLOCKED AND CLOSED ON
<br />FAN SHUTDOWN SHALL BE PROVIDED. ON GRAVITY VENTILATING SYSTEMS, EITHER
<br />AUTOMATIC OR READILY ACCESSIBLE MANUALLY OPERATED DAMPERS IN ALL OPENINGS
<br />TO THE OUTSIDE, OTHER THAN COMBUSTION AIR OPENINGS, SHALL BE PROVIDED.
<br />EQUIPMENT
<br />a. ALL APPLIANCES LISTED IN TABLE 2-53G OF THE CALIFORNIA ADMINISTRATIVE CODE
<br />SHALL HAVE BEEN CERTIFIED TO THE CALIFORNIA ENERGY COMMISSION BY ITS
<br />MANUFACTURER TO COMPLY WITH EFFICIENCY STANDARDS FOR SUCH APPLIANCES.
<br />b. IF ANY COOLING EQUIPMENT OF THE TYPE SPECIFIED ABOVE IS INSTALLED, IT SHALL
<br />MEET OR EXCEED THE CORRESPONDING MINIMUM EFFICIENCY IN TABLE 2-53H OF THE
<br />CAC.
<br />C. IF A FAN TYPE CENTRAL FURNACE WITH INPUT RATE OF AT LEAST 400,000 BTUH OR
<br />A GRAVITY TYPE CENTRAL FURNACE IS INSTALLED, IT SHALL HAVE A MINIMUM
<br />THERMAL EFFICIENCY OF 75%, AS CERTIFIED BY THE MANUFACTURER, BASED ON THE
<br />TEST PROCEDURE ANSI Z21.47-1978.
<br />d. IF OIL FIRED HEATING EQUIPMENT IS INSTALLED, IT SHALL HAVE A MINIMUM
<br />COMBUSTION EFFICIENCY OF 750%0 AT MAXIMUM RATED OUTPUT, AS CERTIFIED BY
<br />MANUFACTURER OF THE EQUIPMENT.
<br />e. FAN TYPE WALL FURNACES AND CENTRAL FURNACES SHALL NOT BE EQUIPPED WITH
<br />CONTINUOUSLY BURNING PILOT, UNLESS THOSE DESIGNED TO BURN ONLY LIQUEFIED
<br />PETROLEUM GASES.
<br />f. HEAT PUMP SHALL BE INSTALLED WITH CONTROLS TO PREVENT ELECTRIC RESISTANCE
<br />SUPPLEMENTARY HEATER OPERATION WHEN THE HEATING LOAD CAN BE MET BY THE
<br />HEAT PUMPS ALONE. ELECTRIC RESISTANCE SUPPLEMENTARY HEATER OPERATION IS
<br />PERMITTED ONLY DURING TRANSIENT PERIODS OR DURING DEFROST. HEAT PUMPS WITH
<br />SUPPLEMENTARY HEAT DERIVED FROM SOURCES OTHER THAN ELECTRIC RESISTANCE
<br />NEED NOT COMPLY WITH THIS SECTION.
<br />Certif icate_o_f_ Complic_nce_Part 2 of 2) Performance Requirements C F-1 B
<br />For Enforcement Agency Use Only
<br />P.oject-TRfe - - Dafe oT-�erfTfTcofa - on r. Area
<br />Documentation Author/Firm Telephone Z`E-Oa�ype Plan Checked By 15aTe
<br />Note. More than one Part 2 may be submitted, but all must reference the same Part 1. The person responsible for design compliance for each
<br />,
<br />yo / _--v -t. . . .
<br />n-F-ar/tnu
<br />Compliance for this building, dated
<br />13
<br />Average Exterior Floor Rt.
<br />-__,_ h-F-sf/Btu i
<br />Signature - Date
<br />rF,S1
<br />4
<br />Average Opaque Wall Rt.
<br />-.-- - h-F-sf/Btu j
<br />1 Average Roof/Ceiling Rt.
<br />15
<br />Glazing Area in Wall . . . . .
<br />__ ___ sf
<br />_'t`1 G (-) I iL _ __- _._._..._ __
<br />Company
<br />16
<br />Average SC (Wall glazing)
<br />_ rt-
<br />I�I0 A HZ, -1
<br />17
<br />Glazing Area in Roof. . . . . .
<br />-__-_ sf
<br />Address
<br />18
<br />Average SC (Roof glazing).
<br />_
<br />. . . . . . . . . . . .
<br />Telephone Cal. License No.
<br />Multiplier. . . . . . . . . . .
<br />Enforcement Agency Date
<br />i�'lyjSfa a ip
<br />Lighting Requirements
<br />1
<br />Enforcement Agency.The proposed building, and future alterations will
<br />19
<br />Allowed Whole Building LPD.
<br />J watts/sf
<br />comply with the California Building Energy Efficiency Standards, provided
<br />20
<br />Allowed Common Areas LPD.
<br />_--�1\ watts/sf
<br />future alterations meet the requirements indicated on this Certificate and
<br />21
<br />Allowed Tenant Space LPD.
<br />-watts/sf I
<br />all applicable mandatory measures, as long as the building occupancy
<br />22
<br />Package Lighting Reduction
<br />vans/sf
<br />type remains unchanged.
<br />23
<br />Lighting Controls Required?.
<br />17
<br />Mechanical Requirements
<br />__-_— sf
<br />-STgnafure - Date - -- - -----
<br />24
<br />System Type. . . . . . . . . . .
<br />- V
<br />Name/Title—
<br />25
<br />Unit Fan Power
<br />- watts/cfm
<br />---- ' Z watts/sf
<br />26
<br />Rated Cooling Efficiency.
<br />_ -- (units)
<br />company - -- - -- - ------
<br />27
<br />Rated Cooling Capacity.
<br />_ (unih)
<br />Package Light Reduction.
<br />28
<br />Rated Heating Efficiency . . .
<br />l (units)
<br />__--
<br />Address
<br />29
<br />Rated Heating Capacity. . . .
<br />-_ (unit')
<br />System Type' . . . . . . . . .
<br />30
<br />Economizer cooling?. . . . . /�
<br />_ (Y/N)
<br />rTFy-/STofe/Zip - --- -- --- - -
<br />26
<br />31
<br />CF -1X Attached?. . . . . . . j.
<br />. . . . . . (YIN)
<br />Rated Cooling Capacity.
<br />—.-_ __- _- (units)
<br />28
<br />Rated Heating Efficiency.
<br />EEM Form Revised September 1988
<br />29
<br />Rated Heating Capacity.
<br />Page �__ of
<br />HVAC SYSTEMS AND CONTROLS
<br />a. HEAT PUMP (IF ANY) SHALL BE INSTALLED WITH A CONTROL TO PREVENT
<br />SUPPLEMENTARY HEATER OPERATION WHEN THE HEATER LOAD CAN BE MET BY THE
<br />HEAT PUMP ALONE.
<br />b. IF CIRCULATING HOT WATER SYSTEM IS INSTALLED, IT SHALL HAVE A CONTROL
<br />CAPABLE OF AUTOMATICALLY TURNING OFF THE CIRCULATING PUMP(S) WHEN HOT
<br />WATER IS NOT REQUIRED.
<br />C. SERVICE WATER HEATING SYSTEM SHALL BE EQUIPPED WITH AUTOMATIC TEMPERATURE
<br />CONTROLS CAPABLE OF ADJUSTMENT FROM THE LOWEST TO THE HIGHEST ACCEPTABLE
<br />TEMPERATURE SETTING FOR THE INTENDED USE AS LISTED IN TABLE 2, CHAPTER 37
<br />OF THE ASHRAE HANDBOOK AND PRODUCT DIRECTORY, SYSTEM VOLUME.
<br />d. EACH ZONE SHALL BE PROVIDED WITH AT LEAST ONE AUTOMATIC TEMPERATURE
<br />CONTROL DEVICE FOR THE REGULATION OF SPACE TEMPERATURE. EACH FLOOR OF THE
<br />BUILDING WITH CONDITIONED SPACE SHALL CONTAIN AT LEAST ONE ZONE.
<br />e. ZONE TEMPERATURE CONTROLS SHALL BE ABLE TO MAINTAIN SPACE TEMPERATURE SET
<br />POINTS FROM 55 DEG.F. TO 85 DEG.F. TWO OR MORE REPLACEABLE FIXED SET POINT
<br />DEVICES, ONE FOR COOLING AND ONE FOR HEATING, MAY BE USED IN LIEU OF
<br />CONTINUOUSLY ADJUSTABLE SET POINT DEVICES.
<br />f. ZONE TEMPERATURE CONTROLS SHALL BE ABLE TO OPERATE ZONE HEATING AND
<br />COOLING IN SEQUENCE IF BOTH ARE PROVIDED.
<br />9. ZONE TEMPERATURE CONTROL SHALL PROVIDE A TEMPERATURE RANGE ADJUSTABLE UP
<br />TO 10 DEG.F. BETWEEN FULL RANGE HEATING AND FULL RANGE COOLING CAPABILITY.
<br />h. ON MECHANICAL VENTILATION SUPPLY AND EXHAUST SYSTEMS CAPABLE OF MOVING
<br />MORE THAN 5,000 CFM OF AIR, AUTOMATIC DAMPERS INTERLOCKED AND CLOSED ON
<br />FAN SHUTDOWN SHALL BE PROVIDED. ON GRAVITY VENTILATING SYSTEMS, EITHER
<br />AUTOMATIC OR READILY ACCESSIBLE MANUALLY OPERATED DAMPERS IN ALL OPENINGS
<br />TO THE OUTSIDE, OTHER THAN COMBUSTION AIR OPENINGS, SHALL BE PROVIDED.
<br />EQUIPMENT
<br />a. ALL APPLIANCES LISTED IN TABLE 2-53G OF THE CALIFORNIA ADMINISTRATIVE CODE
<br />SHALL HAVE BEEN CERTIFIED TO THE CALIFORNIA ENERGY COMMISSION BY ITS
<br />MANUFACTURER TO COMPLY WITH EFFICIENCY STANDARDS FOR SUCH APPLIANCES.
<br />b. IF ANY COOLING EQUIPMENT OF THE TYPE SPECIFIED ABOVE IS INSTALLED, IT SHALL
<br />MEET OR EXCEED THE CORRESPONDING MINIMUM EFFICIENCY IN TABLE 2-53H OF THE
<br />CAC.
<br />C. IF A FAN TYPE CENTRAL FURNACE WITH INPUT RATE OF AT LEAST 400,000 BTUH OR
<br />A GRAVITY TYPE CENTRAL FURNACE IS INSTALLED, IT SHALL HAVE A MINIMUM
<br />THERMAL EFFICIENCY OF 75%, AS CERTIFIED BY THE MANUFACTURER, BASED ON THE
<br />TEST PROCEDURE ANSI Z21.47-1978.
<br />d. IF OIL FIRED HEATING EQUIPMENT IS INSTALLED, IT SHALL HAVE A MINIMUM
<br />COMBUSTION EFFICIENCY OF 750%0 AT MAXIMUM RATED OUTPUT, AS CERTIFIED BY
<br />MANUFACTURER OF THE EQUIPMENT.
<br />e. FAN TYPE WALL FURNACES AND CENTRAL FURNACES SHALL NOT BE EQUIPPED WITH
<br />CONTINUOUSLY BURNING PILOT, UNLESS THOSE DESIGNED TO BURN ONLY LIQUEFIED
<br />PETROLEUM GASES.
<br />f. HEAT PUMP SHALL BE INSTALLED WITH CONTROLS TO PREVENT ELECTRIC RESISTANCE
<br />SUPPLEMENTARY HEATER OPERATION WHEN THE HEATING LOAD CAN BE MET BY THE
<br />HEAT PUMPS ALONE. ELECTRIC RESISTANCE SUPPLEMENTARY HEATER OPERATION IS
<br />PERMITTED ONLY DURING TRANSIENT PERIODS OR DURING DEFROST. HEAT PUMPS WITH
<br />SUPPLEMENTARY HEAT DERIVED FROM SOURCES OTHER THAN ELECTRIC RESISTANCE
<br />NEED NOT COMPLY WITH THIS SECTION.
<br />Certif icate_o_f_ Complic_nce_Part 2 of 2) Performance Requirements C F-1 B
<br />For Enforcement Agency Use Only
<br />P.oject-TRfe - - Dafe oT-�erfTfTcofa - on r. Area
<br />Documentation Author/Firm Telephone Z`E-Oa�ype Plan Checked By 15aTe
<br />Note. More than one Part 2 may be submitted, but all must reference the same Part 1. The person responsible for design compliance for each
<br />major building system acknowledges
<br />the following compliance statement by signing the appropriate space below.
<br />Compliance Statement. The proposed building improvements substantially comply with the requirements indicated on the Certificate of
<br />Compliance for this building, dated
<br />_x/0(1,_. The plans and specifications include the significant energy conservation features and the
<br />compliance documentation is consistent with the plans and specifications.
<br />- -- —
<br />"' i' watts/cfm
<br />Extent of Improvements
<br />Extent of Improvements
<br />Envelope
<br />Allowed Proposed Ptans dated Specs. dated
<br />1 Average Roof/Ceiling Rt.
<br />�-�/ �" /'�� h—F—sf/Btu �Tgnature 15afe
<br />2 Average Exterior Floor Rt.
<br />7 - 7 h-F-sf/Btu
<br />3 Average Opaque Wall Rt.
<br />_
<br />_•�.' = • =� h-F-sf/Btu �me7T1fTe
<br />4 Glazing Area in Wall . . .
<br />. —�'�292st - --
<br />company
<br />5 Average SC (Wall). . . . .
<br />. . -✓ 2 J• /
<br />6 Glazing Area in Roof. . . .
<br />. . - _ - sfAddress
<br />7 Average SC (Roof). . . . .
<br />. . - - -C
<br />Other requirements:
<br />CityState/Zip
<br />. . . . . . . . . . . .
<br />Telephone Cal. License No.
<br />Multiplier. . . . . . . . . . .
<br />Enforcement Agency Date
<br />Mechanical
<br />Unconditioned or Multi -tenant
<br />Allowed
<br />Proposed
<br />Signature
<br />Na m> e 1 f I e
<br />-Company -----
<br />13
<br />Unit Fan Power . . .
<br />- -- —
<br />"' i' watts/cfm
<br />Extent of Improvements
<br />Lighting---
<br />Cooling Efficiency .
<br />. .
<br />Conditioned Floor Area
<br />PTans dated— Specs. date
<br />8
<br />Basis of
<br />Allowed LPD.
<br />- -_
<br />Unconditioned Floor Area.
<br />STgna ore D al e
<br />16
<br />Rated
<br />Heating Efficiency.
<br />Allowed Proposed
<br />f�Ft'�
<br />ame i fe
<br />9
<br />LPD . . .
<br />. . . . . . . . . . . .
<br />watts/sf
<br />Multiplier. . . . . . . . . . .
<br />10
<br />Package
<br />Lighting Reduction.
<br />. . _ .
<br />-
<br />11
<br />Adjusted
<br />LPD. . . . . . . . . . .
<br />—_— ! • %�5 watts/sf
<br />------ -- --
<br />12
<br />Lighting
<br />Control Credits?
<br />_. -/ (Y/N)
<br />Address
<br />15
<br />Other requirements:
<br />_ -z5 2 of
<br />16
<br />City%State%Zip
<br />- -�
<br />16a
<br />Side Fins/Overhangs . . . .
<br />17
<br />Telephone Col. License No.
<br />__-_— sf
<br />18
<br />Average SC (Roof glazing).
<br />-
<br />Enforcement Agency Date
<br />Mechanical
<br />Unconditioned or Multi -tenant
<br />Allowed
<br />Proposed
<br />Signature
<br />Na m> e 1 f I e
<br />-Company -----
<br />13
<br />Unit Fan Power . . .
<br />- -- —
<br />"' i' watts/cfm
<br />14
<br />Rated
<br />Cooling Efficiency .
<br />. .
<br />Conditioned Floor Area
<br />(units)
<br />15
<br />Rated
<br />Cooling Capacity . .
<br />. .(units)
<br />Unconditioned Floor Area.
<br />- sf
<br />16
<br />Rated
<br />Heating Efficiency.
<br />_ -
<br />f�Ft'�
<br />(unit,)
<br />17
<br />Rated
<br />Heating Capacity.
<br />10
<br />Multiplier. . . . . . . . . . .
<br />(units)
<br />18
<br />Economizer cooling? . . .
<br />. . _ .
<br />N (YIN)
<br />19
<br />Simultaneous heat/cool?
<br />__-_-
<br />N (Y/N)
<br />Average Exterior Floor Rt.
<br />_- __1- h-F—sf/Btu
<br />Other
<br />requirements:
<br />h—F—sf/Btu
<br />15
<br />Glazing Area in Wall . . . . .
<br />Extent of Improvements
<br />Unconditioned or Multi -tenant
<br />Plans_c afecT
<br />Specs. dated
<br />Signature
<br />Na m> e 1 f I e
<br />-Company -----
<br />D aTa
<br />------ -
<br />-
<br />Address
<br />CityTtateTZlp------
<br />- -- —
<br />Tefephone
<br />_Caf. License No.
<br />Enforcement Agency
<br />Date
<br />EEM Form Revised September 1988 Page �of
<br />r Vi111.1(_ 11JCII1 ATinm Rtq
<br />Certificate of Compliance (Supplement) Additional R equirements C F - 1 X
<br />For Enforcement Agency Use Only
<br />Project-TffTe —Trate o1�eriTfTcaTe fond. -Fly. Area
<br />Documentation Author F(rm TefepFone -CEC- c� c. Type PFan Checked By Date
<br />The features do specifications established on this CF -1X (CF -1 Part 1 Supplement) are required for the above named project to comply with the
<br />California Building Energy Efficiency Standards. The signatories of the CF -1 Part 1 indicate their knowledge and acceptance of the additional
<br />requirements specified below by their signatures on this form.
<br />Principal Designer Owner Energy Analyst
<br />General Reference
<br />1
<br />Unconditioned or Multi -tenant
<br />shell?.
<br />2
<br />CEC Occupancy Type..
<br />3
<br />UBC Occ. Group/Division.
<br />-_ "z 11 i;' �
<br />4
<br />Climate Zone. . . . . . .
<br />_ -2
<br />5
<br />Conditioned Floor Area
<br />sf
<br />5a
<br />Conditioned Perimeter. . . . .
<br />72 ft
<br />6
<br />Unconditioned Floor Area.
<br />- sf
<br />7
<br />Budget Table (fr. Standards)
<br />-_
<br />8
<br />All. Energy Budget (WS -1A)
<br />-- kwu/sf-yr
<br />9
<br />Calc. Method CEC Code/Date
<br />DWN BY
<br />10
<br />Multiplier. . . . . . . . . . .
<br />. _ =U
<br />11
<br />Calculated Energy Use.
<br />—..—_— _ kBtu/sf—yr 2 77 17-4 -
<br />Envelope Requirements
<br />12
<br />Average Roof/Ceiling Rt.
<br />— '2/'C%(oh—F—sf/Btu
<br />13
<br />Average Exterior Floor Rt.
<br />_- __1- h-F—sf/Btu
<br />14
<br />Average Opaque Wail Rt.
<br />h—F—sf/Btu
<br />15
<br />Glazing Area in Wall . . . . .
<br />_ -z5 2 of
<br />16
<br />Average SC (Wall glazing)
<br />- -�
<br />16a
<br />Side Fins/Overhangs . . . .
<br />17
<br />Glazing Area in Roof. . . . . .
<br />__-_— sf
<br />18
<br />Average SC (Roof glazing).
<br />-
<br />Lighting
<br />Requirements
<br />19
<br />Modeled Zone LPD . . . . . . .
<br />---- ' Z watts/sf
<br />20
<br />Common Area LPD.
<br />watts/sf
<br />21
<br />Tenant Space LPD. . . . . . . .
<br />watts/sf
<br />22
<br />Package Light Reduction.
<br />worts/sf
<br />23
<br />Light Controls Required?.
<br />(Y/N)
<br />Mechanical Requirements
<br />�fGJ c/ii c�Y�L/vl
<br />24
<br />System Type' . . . . . . . . .
<br />LIQ
<br />25
<br />Unit Fan Power . . . . . .
<br />watts/cfm
<br />26
<br />Rated Cooling EFF. . . . . . .
<br />(snits)'
<br />27
<br />Rated Cooling Capacity.
<br />—.-_ __- _- (units)
<br />28
<br />Rated Heating Efficiency.
<br />_ - --(units)
<br />29
<br />Rated Heating Capacity.
<br />`mow —_ (units)
<br />30
<br />Economizer cooling?.
<br />__ -* (Y/N)
<br />•
<br />GF = Gas Furnace, ER = Electric
<br />Resistance, HP = Heat Pump,
<br />OF = Oil Furnace, AC = Air
<br />Conditioning, EC = Evaporative Cooler,
<br />GW = Gas Water Heater, EW
<br />= Electric Water Heater
<br />EEM form Revised September 1988
<br />or
<br />1
<br />3/26/92
<br />RECORD DRAWING -PER CONTRACTOR
<br />_
<br />0
<br />2/2/91
<br />ISSUED FOR CONSTRUCTION
<br />1.M.Aj.
<br />REV
<br />DATE
<br />DESCRIPTION
<br />DWN BY
<br />1DES BY
<br />CHK BY
<br />APP B
<br />DATEOF
<br />1991 UE DnFe RY ICMN,_r.1 I' � � CHK BY�L-��
<br />APP BY
<br />� � r
<br />v 3. /A
<br />DmconE
<br />Rssociaties
<br />FIGURE 1
<br />THIS DRAWING IS TO BE USED FOR
<br />ILLUSTRATION ONLY. SEE ARCHITECTURAL
<br />DRAWINGS FOR ACTUAL BUILDING
<br />SAN JOAQUIN COUNTY
<br />NORTH COUNTY SANITARY LANDFILL
<br />SAN JOAQUIN COUNTY, CALIFORNIA
<br />TITLE 24 FOR SCALE HOUSE
<br />-D
<br />TION
<br />R
<br />A
<br />QRpf ESSl0,y9�
<br />Cc No. 14011
<br />lE OF CAt�FO��
<br />DRAWING NO.
<br />M11
<br />PROJECT NO.
<br />939-02.43
<br />RECORD DRAWING