Laserfiche WebLink
M <br />J <br />Y <br />tn <br />0 <br />rn <br />0 <br />0 <br />w <br />N <br />O <br />rn <br />N <br />0 <br />i <br />0 <br />a <br />U <br />Q <br />V) <br />U <br />w <br />0 <br />0 <br />c� <br />S <br />DWI <br />0 <br />SEE <br />DWG E5 <br />Al <br />SECOND FLOOR POWER PLANE <br />1/8"=1'-0" <br />P2B-30 <br />1 0 1 p (1 1 <br />DP4B-7,9,11 <br />7-- -�[ <br />�- <br />3 <br />1j /- FF -I <br />--W14 <br />2B-1,3 <br />P2B-30 1 <br />19 29 <br />4 <br />� GFI <br />G <br />� #10 <br />P2B-17,19 iG <br />H 2�p P2B-32,34 MAINTENANCE <br />-22 G BAYS <br />SEE P2B-6,8,x@ #10 16 , a� <br />DWG E5 P 2 B - 2 5 -0--- ///- - - II MH=13' Al <br />G 'I <br />LIGHTING C NTROL LC <br />P2B-28 PANEL P4Bi <br />11 [2] PANEL P2B �Z <br />TRANSFORM F R T2 <br />�— PANEL DP40 <br />LP2B-21.��, TELEPHONE ,BACKBOARD TTB 23 31 <br />G #10 pp 27 <br />5 P2BD9411 13,15,17 33 <br />P2B– G <br />8 18 G #6 10 <br />P2B-29,34 1 <br />P4B– Gr29�31,33 <br />413- <br />25,27,29 1� G 33 33,35,37 <br />#6 O 5 11 G <br />24 <br />G O 5 <br />25 S WR2 25 24 G , 25 <br />G O #10 23 G O S 23 0 <br />4 <br />7 #8 <br />fG <br />DP4B <br /># 1 p 31,33,35 <br />P IJ. To <br />PANEL YaB <br />SEALOFF <br />3/4"C - <br />1 #12 & <br />1 #12 G <br />SENSOR 34 <br />J -BOX <br />- 35 <br />ND <br />TO MONITOR <br />PANEL <br />TYPICAL LEAK DETECTOR SENSOR <br />INSTALLATION <br />G <br />O O <br />[2 5 5 <br />G <br />P4B- <br />26,28,0 <br />i <br />� 111 v r4� r4� 4 <br />., ,... v <br />G G ZR <br />S 3/4" CO <br />G 141 FAI <br />S WORK SHOP ❑9 <br />o 170 <br />G <br />O 25 S rVRI 3❑ #6 <br />G5O G <br />P4B- <br />32,34,36 1 <br />ow <br />WP o <br />21 <br />10 <br />G <br />14 <br />10 <br />0 17 WP <br />1 <br />[2 5 <br />P, <br />38, <br />#10 16 <br />P2B-27 "--- <br />G <br />MH=13' <br />00, <br />14 � <br />WP <br />37 <br />Al <br />36 <br />FIRST FLOOR POWER PLAN 11 <br />1/8"=1'-0" <br />- 1"C <br />3 #12, <br />1 #12 GND AND <br />6 #14 <br />ND`T u SED , <br />24 11 <br />21 �l <br />0 2113U <br />WP <br />10 <br />UNAU I HUKILEU L;HANGES, USES AND TIME EFFECTS: EMCON will not be responsible or liable for unauthorized changes to or uses of this plan/drawing. Any change to this <br />plan/drawin must be documented in writing and requires approval by EMCON. This plan/drawing reflects the regulatory requirements or concurrence in effect at the time of its issuance. <br />EQUIPMENT LIST <br />ITEM <br />DESCRIPTION <br />VOLTS <br />PHASE <br />AMPS/WATTS <br />REMARKS <br />1 <br />DIESEL PUMP, 1 1/2 HP <br />208 <br />1 <br />1 1 A <br />— <br />2 <br />VEHICLE WASHER <br />240 <br />1 <br />30A <br />NEMA 6-30 RECEPT <br />W/ WP COVER <br />3 <br />HAND DRYER (TYP 4) <br />208 <br />1 <br />1 1 A <br />KLB <br />4 <br />FORCED AIR HEATING UNIT <br />120 <br />1 <br />13.8A <br />DESCRIPTION <br />5 <br />ROLLUP DOOR, 1 HP (TYP 6) <br />460 <br />3 <br />1.8A <br />6 <br />AIR COMPRESSOR (15 HP) <br />460 <br />3 <br />21A <br />7 <br />UNIT HEATER FAN (1/2 HP) <br />120 <br />1 <br />9.8A <br />8 <br />CRANE <br />460 <br />1 3 <br />30A <br />g <br />SUMP PUMP (1 HP) <br />460 <br />3 <br />1.8A <br />10 <br />CONDENSING UNIT <br />460 <br />3 <br />13.5A <br />11 <br />EXHAUST BLOWER FAN (1 HP) <br />460 <br />3 <br />1.8A <br />12 <br />OIL PUMP (7 1/2 HP) <br />460 <br />3 <br />1 1 A <br />13 <br />RESTROOM FAN <br />120 <br />1 <br />1A <br />14 <br />RIDGE VENT DAMPER (3/4 HP) <br />460 <br />3 <br />1.4A <br />.1� <br />NOTES CONTINUED: <br />Al 36 ROUTE TO PANELBOARD AND DAMPER CONTROL STATION. <br />Al 37 LOCATE DAMPER 3 BUTTON CONTROL ADJACENT TO PANEL DP4B. <br />A 38 CONNECT TO OSY/FS AS SHOWN ON FIRE ALARM RISER DIAGRAM, <br />SEE DWG. E8. <br />15 <br />19 <br />10 <br />#10 <br />P28–� WP <br />G <br />STORAGE <br />AREA <br />#10 19 H 20 <br />WASH PAD <br />P 2 B – 2 2 AREA <br />G WP <br />DP4B-19,21,23 <br />G 21 _ <br />'l 2 O <br />r <br />FUEL <br />TANK1 <br />PUMP <br />32 2 <br />TRANSFORMER T7- 17 I 2 24 <br />#8 <br />P2B-39,41 T <br />G <br />26 <br />- 21 WP <br />-8,10,12 ON L1 ❑ <br />C74SL• G 12 10 <br />LUAC Rack <br />_##18 <br />DP4B-25,27,29 <br />G <br />G5 <br />i # 12 / <br /># 12 N � � <br />G / <br />G <br />#10 <br />WP <br />6" x 6" x 4" <br />Emcon- <br />ASSOCiateS <br />NOTES: <br />1❑ PROVIDE 6"x6"x4" NEMA 3R JUNCTION BOX. ROUTE HOMERUN <br />TO LEAK MONITOR PANEL. <br />LEAK MONITOR ALARM PANEL. CONNECT TO CIRCUIT P28-37. <br />3❑ PROVIDE 50A, 250V, 2P, 3W, NEMA 6-50, WELDING OUTLETS. <br />IN3TiRE1vtOCU'317i7ti; `2�A DUPLEX RE�i�TA�CES-`AT"rt2" <br />E)N-CET Tf-R-flf--THE-WORK--BEf4C+IE--S. 1PLOoR. LUGS <br />5❑ CONNECT TO KEYLESS FIXTURE, SEE DWG E5. <br />6❑ DEDICATED TIME CLOCK RECEPTACLE. <br />l� DEDICATED DRINKING FOUNTAIN RECEPTACLE. <br />[8] DIESEL PUMP SHUTOFF SWITCH, 30A, 250V, 2P, NEMA 3R. <br />ENGRAVE LAMINATED PLASTIC NAMEPLATE "DIESEL PUMP" ALSO <br />ENGRAVE A SIGN WITH 2" HIGH LETTERS, "EMERGENCY PUMP <br />SHUTOFF". <br />9❑ LOCATE DUPLEX RECEPTACLES AT 42" ABOVE FINISHED FLOOR <br />IN THE MAINTENANCE BAYS, SHOP AND PARTS STORAGE AREAS. <br />10 LOCATE EXTERIOR DUPLEX RECEPTACLES AT 24" ABOVE <br />FINISHED FLOOR. INSTALL GFI TYPE RECEPTACLES. <br />11 UNLESS SHOWN OTHERWISE, EACH CONDUIT WILL CONTAIN THREE <br />NO. 12 AWG WIRES, ONE HOT, ONE NEUTRAL AND ONE GROUND. <br />12 DEDICATED 250V VEHICLE WASHING EQUIPMENT EXTERIOR RECEPTACLE. <br />13 DEDICATED ICE MAKER RECEPTACLE. <br />14 DEDICATED MICROWAVE RECEPTACLE. <br />H <br />15 DEDICATED VENDING MACHINE RECEPTACLE. <br />16 RECEPTACLE FOR PORTABLE LAMP AND POWER REAL CORD UINT. <br />FURNISH AND INSTALL NEMA 5-20 CONNECTOR BODY FOR POWER <br />CORD UNIT. <br />17 INSTALL 30A -2P CIRCUIT BREAKER WITH NEMA 1 ENCLOSURE. <br />18 WASH PAD HIGH SUMP LEVEL ALARM. FURNISH AND INSTALL <br />FLYGT #ENH-10 FLOAT SWITCH WITH 60' CABLE. <br />5TA,1NLESS ENCIoSURE Uj1x8"<.4T0Q Li6W-T% <br />1 gRONAN MH=42" . <br />2p ALARM HORN, FEDERAL #302GC-120VAC–TM6. MH=15'. <br />21 NEMA 3R NF COMBINATION STARTER, SIZE 1, WITH START–STOP, <br />RED RUNNING LIGHT AND CPT. <br />22 STUB 3/4"CO INTO ACCESSIBLE GRID CEILING SPACE. TYPICAL <br />FOR TELEPHONE AND DATA OUTLETS. <br />23 STUB (3) 2"CO INTO 2nd FLOOR (LUNCH ROOM) ACCESSIBLE <br />CEILING SPACE. <br />24 CONNECT TO LEAK DETECTION ALARM SENSOR AS DIRECTED BY THE <br />LEAK DETECTION EQUIPMENT VENDOR SHOP DRAWINGS. <br />25 INSTALL AND CONNECT ROLLUP DOOR CONTROL STATION. <br />2 NEMA 1 NF COMBINATION STARTER, WITH HAND–OFF–AUTO, <br />RED RUNNING LIGHT AND CPT. CONNECT AND WIRE INTERLOCK <br />CONTROL DEVICES. <br />27 NEMA 1 NF COMBINATION STARTER, SIZE 1, WITH START–STOP, <br />RED RUNNING LIGHT AND CPT. <br />28 MAINTENANCE BAYS AND STORAGE AREA ARE TO BE WIRED IN <br />ACCORDANCE WITH NEC ARTICLE 511. <br />29 COMMON TROUBLE ALARM FOR PUMP HOUSE. ENGRAVE NAMEPLATE <br />"PUMP HOUSE TROUBLE". <br />30 CONNECT TO EXHAUST FAN. ROUTE HOMERUN TO PANEL P28 VIA <br />CONTACTOR AT FORCED AIR UNIT. <br />31 CONNECT TO SCALE DIGITAL READOUT AND SIGNAL CONTROL <br />UNITS, P2B-24. <br />32 CONNECT TO TANK LEVEL CONTROL AS DIRECTED BY THE LEAK <br />DETECTION EQUIPMENT VENDOR SHOP DRAWINGS. <br />33 ROUTE TO LEAK MONITOR PANEL. <br />34 SUPPORT SENSOR CABLE USING STRAPS APPROVED FOR CABLE USE. <br />TERMINATE CABLE AT J–BOX USING STRAIN RELIEF CORD CONNECTOR. <br />35 INSTALL SENSOR IN PIPE, OR TANK SECONDARY CONTAINMENT SPACE <br />AS DIRECTED BY THE LEAK DETECTION MANUFACTURER. <br />/11'.1' /,1�`',kN <br />"�.. < r <br />1J0. 1', 4 <br />1 Exp <br />SAN JOAQUIN COUNTY <br />NORTH COUNTY SANITARY LANDFILL <br />SAN JOAQUIN COUNTY, CALIFORNIA <br />OFFICE/MAINTENANCE POWER PLAN <br />DRAWING N0. <br />E6 <br />PROJECT NO. <br />939-02.43 <br />REGURD DRAWING <br />2 <br />3/26/92 <br />RECORD DRAWING -PER CONTRACTOR <br />— <br />1 <br />3/18/91 <br />PLAN CHECK 3/12/912 <br />0 <br />2/2/91 <br />ISSUED FOR CONSTRUCTION <br />KLB <br />KLB <br />FJP <br />FJP <br />DESCRIPTION <br />6 -WN B <br />DES BY <br />CHK BY <br />APP B <br />_REVDATE — <br />DATE OF ISSUE OWN BY_KBIBY CHK BY -1--j- PROFFITT <br />SEB 1991 DES BY KLB _ _ APP BY F.J. PROFFITT <br />Emcon- <br />ASSOCiateS <br />NOTES: <br />1❑ PROVIDE 6"x6"x4" NEMA 3R JUNCTION BOX. ROUTE HOMERUN <br />TO LEAK MONITOR PANEL. <br />LEAK MONITOR ALARM PANEL. CONNECT TO CIRCUIT P28-37. <br />3❑ PROVIDE 50A, 250V, 2P, 3W, NEMA 6-50, WELDING OUTLETS. <br />IN3TiRE1vtOCU'317i7ti; `2�A DUPLEX RE�i�TA�CES-`AT"rt2" <br />E)N-CET Tf-R-flf--THE-WORK--BEf4C+IE--S. 1PLOoR. LUGS <br />5❑ CONNECT TO KEYLESS FIXTURE, SEE DWG E5. <br />6❑ DEDICATED TIME CLOCK RECEPTACLE. <br />l� DEDICATED DRINKING FOUNTAIN RECEPTACLE. <br />[8] DIESEL PUMP SHUTOFF SWITCH, 30A, 250V, 2P, NEMA 3R. <br />ENGRAVE LAMINATED PLASTIC NAMEPLATE "DIESEL PUMP" ALSO <br />ENGRAVE A SIGN WITH 2" HIGH LETTERS, "EMERGENCY PUMP <br />SHUTOFF". <br />9❑ LOCATE DUPLEX RECEPTACLES AT 42" ABOVE FINISHED FLOOR <br />IN THE MAINTENANCE BAYS, SHOP AND PARTS STORAGE AREAS. <br />10 LOCATE EXTERIOR DUPLEX RECEPTACLES AT 24" ABOVE <br />FINISHED FLOOR. INSTALL GFI TYPE RECEPTACLES. <br />11 UNLESS SHOWN OTHERWISE, EACH CONDUIT WILL CONTAIN THREE <br />NO. 12 AWG WIRES, ONE HOT, ONE NEUTRAL AND ONE GROUND. <br />12 DEDICATED 250V VEHICLE WASHING EQUIPMENT EXTERIOR RECEPTACLE. <br />13 DEDICATED ICE MAKER RECEPTACLE. <br />14 DEDICATED MICROWAVE RECEPTACLE. <br />H <br />15 DEDICATED VENDING MACHINE RECEPTACLE. <br />16 RECEPTACLE FOR PORTABLE LAMP AND POWER REAL CORD UINT. <br />FURNISH AND INSTALL NEMA 5-20 CONNECTOR BODY FOR POWER <br />CORD UNIT. <br />17 INSTALL 30A -2P CIRCUIT BREAKER WITH NEMA 1 ENCLOSURE. <br />18 WASH PAD HIGH SUMP LEVEL ALARM. FURNISH AND INSTALL <br />FLYGT #ENH-10 FLOAT SWITCH WITH 60' CABLE. <br />5TA,1NLESS ENCIoSURE Uj1x8"<.4T0Q Li6W-T% <br />1 gRONAN MH=42" . <br />2p ALARM HORN, FEDERAL #302GC-120VAC–TM6. MH=15'. <br />21 NEMA 3R NF COMBINATION STARTER, SIZE 1, WITH START–STOP, <br />RED RUNNING LIGHT AND CPT. <br />22 STUB 3/4"CO INTO ACCESSIBLE GRID CEILING SPACE. TYPICAL <br />FOR TELEPHONE AND DATA OUTLETS. <br />23 STUB (3) 2"CO INTO 2nd FLOOR (LUNCH ROOM) ACCESSIBLE <br />CEILING SPACE. <br />24 CONNECT TO LEAK DETECTION ALARM SENSOR AS DIRECTED BY THE <br />LEAK DETECTION EQUIPMENT VENDOR SHOP DRAWINGS. <br />25 INSTALL AND CONNECT ROLLUP DOOR CONTROL STATION. <br />2 NEMA 1 NF COMBINATION STARTER, WITH HAND–OFF–AUTO, <br />RED RUNNING LIGHT AND CPT. CONNECT AND WIRE INTERLOCK <br />CONTROL DEVICES. <br />27 NEMA 1 NF COMBINATION STARTER, SIZE 1, WITH START–STOP, <br />RED RUNNING LIGHT AND CPT. <br />28 MAINTENANCE BAYS AND STORAGE AREA ARE TO BE WIRED IN <br />ACCORDANCE WITH NEC ARTICLE 511. <br />29 COMMON TROUBLE ALARM FOR PUMP HOUSE. ENGRAVE NAMEPLATE <br />"PUMP HOUSE TROUBLE". <br />30 CONNECT TO EXHAUST FAN. ROUTE HOMERUN TO PANEL P28 VIA <br />CONTACTOR AT FORCED AIR UNIT. <br />31 CONNECT TO SCALE DIGITAL READOUT AND SIGNAL CONTROL <br />UNITS, P2B-24. <br />32 CONNECT TO TANK LEVEL CONTROL AS DIRECTED BY THE LEAK <br />DETECTION EQUIPMENT VENDOR SHOP DRAWINGS. <br />33 ROUTE TO LEAK MONITOR PANEL. <br />34 SUPPORT SENSOR CABLE USING STRAPS APPROVED FOR CABLE USE. <br />TERMINATE CABLE AT J–BOX USING STRAIN RELIEF CORD CONNECTOR. <br />35 INSTALL SENSOR IN PIPE, OR TANK SECONDARY CONTAINMENT SPACE <br />AS DIRECTED BY THE LEAK DETECTION MANUFACTURER. <br />/11'.1' /,1�`',kN <br />"�.. < r <br />1J0. 1', 4 <br />1 Exp <br />SAN JOAQUIN COUNTY <br />NORTH COUNTY SANITARY LANDFILL <br />SAN JOAQUIN COUNTY, CALIFORNIA <br />OFFICE/MAINTENANCE POWER PLAN <br />DRAWING N0. <br />E6 <br />PROJECT NO. <br />939-02.43 <br />REGURD DRAWING <br />