<br />GENERAL NOTES
<br />1. THE CONTRACTOR AGREES THAT, IN ACCORDANCE WI TH GENERALL Y
<br />ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE REQUIRED
<br />TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB S1 TE
<br />CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT,
<br />INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT
<br />SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
<br />WORK/NG HOURS. THE CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY
<br />AND HOLD OWNER, CITY, COUNTY AND ENGINEER HARMLESS FROM ANY AND
<br />ALL L IABIL I TY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE
<br />OF WORK ON THIS PROJECT, EXEMPTING LIABILITY ARISING FROM THE
<br />SOLE NEGLIGENCE OF ENGINEER.
<br />2. EXCAVATIONS SHALL BE ADEQUATELY SHORED, BRACED AND SHEETED
<br />SO THAT THE EARTH WILL NOT SLIDE OR SETTLE AND SO THAT ALL
<br />EXISTING IMPROVEMENTS OF ANY KIND WILL BE FULLY PROTECTED FROM
<br />DAMAGE. ANY DAMAGE RESULTING FRAM A LACK OF ADEOUATE SHORING,
<br />BRACING AND SHEETING, SHALL BE THE RESPONSIBILITY OF THE
<br />CONTRACTOR AND HE SHALL EFFECT NECESSARY REPAIRS OR
<br />RECONSTRUCTION AT HIS OWN EXPENSE. WHERE THE EXCAVATION FOR A
<br />CONDUIT TRENCH, AND/OR STRUCTURE IS FIVE FEET OR MORE IN DEPTH,
<br />THE CONTRACTOR SHALL PROVIDE ADEQUATE SHEETING, SHORING AND
<br />BRACING OR EQUIVALENT METHOD, FOR THE PROTECTION OF LIFE, OR LIMP,
<br />WHICH SHALL CONFORM TO THE APPLICABLE CONSTRUCTION SAFETY ORDERS
<br />OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA.
<br />THE CONTRACTOR SHALL ALWAYS COMPLY WITH OSHA REQUIREMENTS.
<br />J. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN PERMITS
<br />NECESSARY TO PERFORM THE WORK SHOWN /N THESE PLANS FROM THE
<br />APPROPRIATE AGENCIES.
<br />4. THE CONTRACTOR SHALL TAKE EFFECTIVE ACTION TO PREVENT THE
<br />FORMATION OF AIRBORNE DUST NUISANCE AND SHALL BE RESPONSIBLE FOR
<br />ANY DAMAGE RESULTING FROM HIS FAILURE TO DO SO.
<br />5. THE CONTRACTOR SHALL PROVIDE FOR INGRESS AND EGRESS FOR
<br />PRIVATE PROPERTY ADJACENT TO WORK THROUGHOUT THE PERIOD OF THE
<br />CONSTRUCTION.
<br />6. THE CONTRACTOR SHALL PROVIDE ALL LIGHTS, SIGNS, BARRICADES,
<br />FLAGGERS OR OTHER DEVICES NECESSARY TO PROVIDE FAR SAFETY.
<br />7. THE CONTRACTOR SHALL POST EMERGENCY TELEPHONE NUMPERS FOR POLICE,
<br />FIRE, AAPULANCE, AND THOSE AGENCIES RESPONSIBLE FOR MAINTENANCE
<br />OF UTILITIES IN THE VICINITY OF JOB SITE.
<br />B. ANY EXTRA CONSTRUCTION STAKING NECESSITATED SOLELY BY THE
<br />CONTRACTOR'S NEGLIGENCE WILL BE CHARGED TO THE CONTRACTOR ON A
<br />TIME AND EXPENSES BASIS, AND PAID FOR BY THE CONTRACTOR.
<br />9. STATIONING HEREON IS ALONG STREET CENTERLINE UNLESS OTHERWISE
<br />SHOWN OR INDICATED.
<br />10. ALL RETURN RADII AND CURB DATA ARE TO FACE OF CURB.
<br />11. ALL QUANTITIES AND PAY ITEMS ARE AND WILL BE BASED DN HORIZONTAL
<br />MEASUREMENTS.
<br />12. LENGTHS OF SANITARY SEWERS AND STORM DRAINS ARE HORIZONTAL
<br />DISTANCES FROM CENTER TO CENTER OF STRUCTURES, ROUNDED OFF TO THE
<br />NEAREST FOOT.
<br />13. EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN
<br />THEIR APPROXIMATE LOCATIONS BASED UPON RECORD INFORMATION
<br />AVAILABLE TO THE ENGINEER AT THE TIME OF THE PREPARATION OF THESE
<br />PLANS. LOCATIONS MAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO
<br />GUARANTEE IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE
<br />INFORMATION SHOWN. THE CONTRACTOR SHALL NOTIFY UTILITY COMPANIES
<br />AT LEAST (3) WORKING DAYS IN ADVANCE OF CONSTRUCTION TO FIELD
<br />LOCATE UTILITIES. CALL UNDERGROUND SERVICE ALERT (U.S.A.), AT
<br />800-642-2444. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
<br />DETERMINE THE EXISTENCE AND LOCATION OF THOSE UTILITIES SHOWN ON
<br />THESE PLANS OR INDICATED IN THE FIELD BY LOCATING SERVICES.
<br />ANY ADDITIONAL COSTS INCURRED AS A RESULT OF CONTRACTOR'S FAILURE
<br />TO VERIFY LOCATIONS OF EXISTING UTILITIES PRIOR TO BEGINNING OF
<br />CONSTRUCTION /N THEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR
<br />AND ASSUMED INCLUDED AND MERGED IN THE CONTRACT UNIT PRICE.
<br />14. ALL EXISTING UTILITIES AND IMPROVEMENTS THAT BECOME DAMAGED
<br />DURING CONSTRUCTION SHALL BE COMPLETELY RESTORED TO THE
<br />SATISFACTION OF THE LOCAL AGENCY ENGINEER, AT THE CONTRACTOR'S
<br />SOLE EXPENSE.
<br />15. ANY RELOCATION OF PUBLIC UTILITIES SHALL BE CONDUCTED IN
<br />ACCORDANCE WITH ANY AND ALL REQUIREMENTS OF THE UTILITY COMPANY
<br />INCLUDING FEES, BONDS, PERMITS AND WORKING CONDITIONS, ETC. THIS
<br />WORK SHALL BE DONE AT NO EXPENSE TO THE UTILITY COMPANY. THE
<br />OWNER SHALL PAY THE COST OF ALL SUCH RELOCATIONS WORK INCLUDING
<br />FEES, BONDS, PERMITS, ETC.
<br />16. IF ARCHAEOLOGICAL MATERIAL ARE UNCOVERED DURING GRADING,
<br />TRENCHING OR OTHER EXCAVATION, EARTHWORK WITHIN 100 FEET OF THESE
<br />MATER/ALS SHALL BE STOPPED UNTIL A PROFESSIONAL ARCHAEOLOGIST WHO
<br />IS CERTIFIED BY THE SOCIETY OF CALIFORNIA ARCHAEOLOGY (SCA)
<br />AND/OR THE SOCIETY OF PROFESSIONAL ARCHAEOLOGY (SOPA) HAS HAD
<br />AN OPPORTUNITY TO EVALUATE THE SIGNIFICANCE OF THE FIND AND
<br />SUGGEST APPROPRIATE MITIGATION MEASURES IF THEY ARE DEEMED
<br />NECESSARY.
<br />17. RUGGERI - JENSEN - AZAR AND ASSOCIATES (RJA) DOES NOT SPECIFY NOR
<br />RECOMMEND THE USE OR INSTALLATION OF ANY MATERIAL OR EQUIPMENT
<br />WHICH IS MADE FRAM, OR W41CH CONTAINS ASBESTOS FOR USE IN THE
<br />CONSTRUCTION OF THESE IMPROVEMENT. ANY PARTY INSTALLING OR USING
<br />SUCH MATER I ALS OR EQUIPMENT SHALL BE SOLELY RESPONSIBLE FOR ALL
<br />INJURIES, DAMAGES, OR LIABILITIES, OF ANY KIND, CAUSED BY THE USE
<br />OF SUCH MATERIALS OR EQUIPMENT. THE PROVISIONS OF THIS NOTE SHALL
<br />APPLY UNLESS THEY ARE EXPRESSLY WAIVED IN WRITING BY
<br />RUGGERI - JENSEN - AZAR AND ASSOCIATES.
<br />18. THE CONTRACTOR SHALL MEET AND FOLLOW ALL NPO£S REQUIREMENTS IN
<br />EFFECT AT THE TIME OF CONSTRUCTION.
<br />19. SHOULD IT APPEAR THA T THE WORK TO BE DONE OR ANY MATTER RELATIVE
<br />THERETO IS NOT SUFFICIENTLY DETAILED OR EXPLAINED ON THESE
<br />PLANS, THE CONTRACTOR SHALL CONTACT RJA AT (510) 227-9100 FOR
<br />SUCH FURTHER EXPLANATIONS AS MAY BE NECESSARY.
<br />PROJECT GENERAL NOTES
<br />1. ALL WORK, EXCEPT SANITARY SEWER AND WATER, SHALL CONFORM TO SAN
<br />JOAQUIN COUNTY, DEPARTMENT OF PUBLIC WORKS STANDARD
<br />SPECIFICATIONS AND DETAILS PER CURRENT EDITION. THE IMPROVEMENTS
<br />ARE SUBJECT TO THE INSPECT/ON AND APPROVAL OF THE COUNTY PUBLIC
<br />WORKS DIRECTOR. CONTACT COUNTY PUBLIC WORKS DEPARTMENT TWO
<br />WORKING DAYS (48 HOURS) PRIOR TO THE START OF ANY WORK TO ARRANGE
<br />FOR INSPECTION.
<br />2. ALL SANITARY SEWER AND WATER WORK SHALL BE DONE IN ACCORDANCE
<br />W1TH CITY OF TRACY, DEPARTMENT OF PUBLIC WORKS STANDARDS &
<br />SPECIFICATIONS, CURRENT EDITION. THE IMPROVEMENTS ARE SUBJECT TO
<br />THE INSPECTION AND APPROVAL OF THE CITY PUBLIC WORKS DIRECTOR.
<br />CONTACT CITY PUBLIC WORKS DEPARTMENT TWO WORKING DAYS (48 HOURS)
<br />PRIOR TO THE START OF ANY SANITARY SEWER AND WATER WORK TO
<br />ARRANGE FOR INSPECTION.
<br />J. THE CONTRACTOR SHALL OBTAIN PERMITS FROM THE CITY OF TRACY AND
<br />SAN JOAQUIN COUNTY PUBLIC WORKS DEPARTMENT PRIOR TO BEGINNING
<br />WORK.
<br />4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY NOTIFY
<br />AN ASSOCIATES,
<br />THE COUNTY OR THE CITY, AND RUGGERI-JENSEN-AZAR D SSOC ,
<br />UPON DISCOVERY OF ANY CONFLICTS WITH THE PLANS, SPECIFICATIONS OR
<br />FIELD CONDITIONS. ANY DEVIATIONS OR CHANGES IN THESE PLANS
<br />WITHOUT OFFICIAL APPROVAL OF THE DESIGN ENG/NEER SHALL ABSOLVE
<br />THE DESIGN ENGINEER OF ANY AND ALL RESPONSIBILITY OF SAID
<br />DEVIATION OR CHANGE.
<br />5. THE CONTRACTOR SHALL NOT DESTROY ANY PERMANENT SURVEY POINTS
<br />WITHOUT THE CONSENT OF THE COUNTY SURVEYOR. ANY PERMANENT
<br />MOMAMENTS OR POINTS DESTROYED SHALL BE REPLACE BY A LICENSED
<br />CIVIL ENGINEER AUTHORIZED TO DO SURVEYING, OR A LICENSED LAND
<br />SURVEYOR AT THE CONTRACTOR'S EXPENSE, BEFORE ACCEPTANCE OF
<br />IMPROVEMENTS BY SAN JOAQUIN COUNTY.
<br />6. ALL CONSTRUCTION STAKING SHALL BE DONE BY A REGISTERED CIVIL
<br />ENGINEER, AUTHORIZED TO DO SURVEYING OR A LICENSED LAND SURVEYOR.
<br />7. EXISTING UTILITIES ARE PLOTTED FROM AVAILABLE RECORDS. THE
<br />CONTRACTOR SHALL TAKE PRECAUTIONARY MEASURES TO PROTECT THESE
<br />UTILITIES. THE CONTRACTOR SHALL NOT DO ANY EXCAVATIONS UNTIL ALL
<br />UTILITY AGENCIES OF SAN JOAQUIN COUNTY AND THE CITY OF TRACY HAVE
<br />BEEN NOTIFIED AND HAVE BEEN GIVEN THE OPPORTUNITY TO MARK THEIR
<br />FACILITIES IN THE FIELD.
<br />8. CONTRACTOR SHALL CONTROL DUST AT ALL TIMES DURING CONSTRUCTION AS
<br />REQUIRED BY THE COUNTY OF SAN JOAQUIN.
<br />9. PRIOR TO TRENCHING FOR ALL UTILITY PIPE, THE CONTRACTOR SHALL
<br />VERIFY, IN THE FIELD, THE SIZE AND LOCATION OF THE EXISTING PIPE
<br />AT THE POINT OF CONNECTION. ANY DEVIATION FROM THE PLANS SHALL
<br />BE RESOLVED BY THE DESIGN ENGINEER PRIOR TO TRENCHING. CONTRACTOR
<br />SHALL BE RESPONSIBLE FOR COORDINATION OF FIELD VERIFICATION.
<br />DESIGN ENGINEER SHALL BE ALLOWED REASONABLE TIME FOR CONFLICT
<br />RESOLUTION.
<br />10. MANHOLES, VALVES, CLEANOUT -S, ETC. SHALL BE BROUGHT TO FINISH GRADE
<br />BY THE CONTRACTOR AFTER THE FINAL PAVING COURSE IS PLACED. WATER
<br />VALVES MUST REMAIN ACCESSIBLE AT ALL TIMES DURING CONSTRUCTION.
<br />11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE NECESSARY
<br />PUBLIC AND PRIVATE ENTITIES, WHO HAVE AN INTEREST IN THE
<br />CONSTRUCTION OF THESE IMPROVEMENTS AS IT IMPACTS THEM, IN A TIMELY
<br />MANNER TO ALLOW THEM TO SEND THE NECESSARY REPRESENTATIVES TO THE
<br />JOB SITE FOR INSPECTION AND OBSERVATION PURPOSES.
<br />12. THE NLAIVER AND LOCATIONS OF CONSTRUCTION STAKES SHALL BE
<br />DETERMINED BEFORE THE CONSTRUCTION BEGINS. ALL STAKING REQUESTS
<br />SHOULD BE DIRECTED TO THE DESIGN ENGINEER A M/N/MUV OF TWO
<br />WORKING DAYS PRIOR TO ACTUAL NEED. ANY ADDITIONAL STAKING OR
<br />RESTAK/NG WILL ONLY BE DONE AS DIRECTED AND AUTHORIZED BY THE
<br />OWNER OR HIS AUTHORIZED AGENT. RESTAKING WILL BE BILLED TO THE
<br />CONTRACTOR.
<br />13. THE EXISTING TOPOGRAPHY AND IMPROVEMENTS SHOWN DN THESE PLANS ARE
<br />BASED ON A FIELD SURVEY DATED MARCH 1993.
<br />CONSTRUCTION NOTES
<br />1. ALL CONSTRUCTION MATERIALS AND METHODS SHALL COMPLY WITH THE
<br />ORDINANCES, SPECIFICATIONS, AND STANDARDS OF SAN JOAQUIN COUNTY
<br />AND THE CITY OF TRACY (WATER AND SEWER ONLY), EXCEPT AS NOTED
<br />BELOW FOR SPECIFIC UTILITIES.
<br />2. TRAFFIC CONTROL, AMINTENANCE AND OPERATION SHALL COMPLY WITH THE
<br />FOLLOWING STATE STANDARD SPECIFICATION: SECTION 7-1.09 "PUBLIC
<br />SAFETY', SECTION 7-108 'PUBLIC CONVENIENCE', AND SECTION 12
<br />"CONSTRUCTION AREA TRAFFIC CONTROL DEVICES". CONTRACTOR SHALL BE
<br />RESPONSIBLE FOR PROVIDING AND MAINTAINING ALL NECESSARY TRAFFIC
<br />CONTROL, INCLUDING TEMPORARY STRIPING, INSTALLATION OF SEMI
<br />PERMANENT TRAFFIC CONTROL DEVICES, AT ALL TIMES.
<br />J. ALL TRENCH EXCAVATION OVER FIVE FEET IN DEPTH SHALL BE SHORED IN
<br />ACCORDANCE WITH CAL -OSHA 'CONSTRUCTION SAFETY ORDERS' CURRENT
<br />EDITION. CONTRACTOR MUST HAVE VALID TRENCH SHORING PERMIT ISSUED
<br />BY CAL -OSHA.
<br />4. CONTRACTOR SHALL PROVIDE A MINIMUM OF 2 LANES, ONE IN EACH
<br />DIRECTION, AT ALL TIMES ON PATTERSON PASS ROAD.
<br />SANITARY SEWER
<br />1. GRAVITY SANITARY SEWER PIPE AND LATERAL SHALL BE VITRIFIED CLAY
<br />PIPE (VCP) PER CITY STANDARD SPECS. 207.01.
<br />2. SANITARY SEWER MANHOLE SHALL CONFORM TO THE CITY OF TRACY
<br />STANDARD DRAWING NO. 301.
<br />J. ALL SANITARY SEWER MAINS SHALL BE TELEVISION INSPECTED, AND PASS
<br />A LEAKAGE TEST PRIOR TO ACCEPTANCE BY THE CITY F TRACY. (SEE
<br />NOTE NO. 10, APPENDIX 'B', CITY OF TRACY DESIGN STANDARDS.)
<br />4. ALL SANITARY SEWER LATERALS SHALL HAVE A CLEANOUT ONE FOOT
<br />INSIDE THE RIGHT OF WAY. SANITARY SEWER CLEANOUT SHALL CONFORM
<br />TO THE CITY OF TRACY STANDARD DRAWING NO. 203.
<br />5. THE SANITARY SEWER FORCE MAIN (SSFM) SHALL BE CLASS 50 DUCTILE
<br />IRON PIPE (DIP), AND SHALL HAVE A MIN/MGM COVER OF 42" OVER THE
<br />PIPE.
<br />6. SSFM FITTINGS SHALL BE MECHANICAL JOINT AND DUCTILE IRON.
<br />7. TRENCH BEDDING AND BACKFILL SHALL CONFORM TO THE DETAIL ON SHEET
<br />14.
<br />STORM DRAIN
<br />1. ALL STORM DRAIN SHALL BE REINFORCED CONCRETE PIPE (RCP) CLASS
<br />/it, UNLESS OTHERWISE NOTED ON THE PLANS. AT THE CONTRACTOR'S
<br />OPTION, AN EQUIVALENT STRENGTH CAST -IN-PLACE CONCRETE PIPE MAY BE
<br />USED.
<br />2. CATCH BASIN SHALL BE TYPE 2 PER SAN JOAQUIN COUNTY STANDARD
<br />DRAWING NO. D-14.
<br />J. STORM DRAIN MANHOLES SHALL BE SADDLE TYPE MANHOLE CONFORM/NG TO
<br />SAN JOAQUIN COUNTY STANDARD DRAWING NO. D-18. STORM DRAIN MH 122,
<br />,/29 TO f33 SHALL BE PER STORM DRAIN MANHOLE DETAIL ON SHEET 4.
<br />WATER
<br />1. WATER MANN SHALL BE DUCTILE IRON PIPE (DIP) PER CITY STANDARD
<br />SPECS. 207.04 CLASS 50 AND SHALL HAVE A MINIMUM COVER OF 41' OVER
<br />THE PIPE.
<br />2. ALL FITTINGS SHALL BE MECHANICAL JOINT DUCTILE IRON. FITTING
<br />WITH VALVE SHALL BE MECHANICAL JOINT BY FLANGE.
<br />J. VALVES 10' AND SAIALLER SHALL BE RESI L I ENT SEATED GATE VALVE
<br />CONFORMING TO THE REQUIREMENTS OF THE CITY OF TRACY STANDARD
<br />SPECIFICATIONS. NO VALVE SHALL BE INSTALLED UNTIL APPROVAL FOR
<br />THE PARTICULAR BRAND NAME AND MANUFACTURER'S MODEL NUMBER HAS
<br />BEEN GRANTED BY THE CITY PUBLIC WORKS DIRECTOR. VALVES 12' AND
<br />LARGER SHALL BE BUTTERFLY VALVES, EPDXY LINED, CONFORMING TO
<br />THE REQUIREMENTS OF THE CITY OF TRACY STANDARD SPECIFICATIONS.
<br />4. TESTING OF THE PIPE SHALL BE MADE IN ACCORDANCE WITH THE
<br />REQUIREMENTS OF SECTION 306.15 OF THE CITY OF TRACY STANDARD
<br />SPECIFICATIONS. ALL PIPES SHALL BE TESTED AT THE PRESENCE OF THE
<br />CITY PUBLIC WORKS DIRECTOR OR HIS REPRESENTATIVE. TESTING OF
<br />THE PIPE SHALL BE DONE BEFORE CONNECTION TO THE EXISTING WATER
<br />MAIN AND AFTER COMPACTION OF THE BASIC MATERIAL. CONTRACTOR SHALL
<br />BE RESPONSIBLE FOR THE TESTING, RETESTING AND RECOMPACTION OF THE
<br />PIPE AS REQUIRED AT HIS OWN EXPENSE TO THE SATISFACTION OF THE
<br />CITY ENGINEER.
<br />5. PRIOR TO DELIVERY TO THE JOB SITE, THE CONTRACTOR SHALL FURNISH
<br />A COMPLETE LIST OF MATERIALS BY MANUFACTURER AND MODEL NUAPER FOR
<br />APPROVAL BY THE CITY PUBLIC WORKS DIRECTOR, AND A CERTIFICATE OF
<br />COMPLIANCE SHALL BE FURNISHED BY THE MANUFACTURER FOR ALL PIPE
<br />FURNISHED.
<br />6. ALL WATER SERVICES (DOMESTIC, FIRE, HYDRANTS, ETC.) MUST MAINTAIN
<br />12' CLEARANCE FRAM OTHER UT IL I TIES.
<br />7. WATER METER BOXES SHALL BE INSTALLED FOR ALL SERVICES PER CITY OF
<br />TRACY STANDARD DRAWINGS 403, 405, OR 406. NO WATER METERS WILL BE
<br />INSTALLED AT THIS TIME.
<br />8. THRUST BLOCKS SHALL BE INSTALLED AT ALL BENDS AND FITTING PER
<br />CITY OF TRACY DETAIL ,/423.
<br />9. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF TRACY DETAIL 1401.
<br />10. TRENCH BEDDING AND BACKFILL SHALL CONFORM TO THE REQUIREMENTS OF
<br />THE PROJECT SUBDIVISION SPECIFICATION.
<br />CONCRETE
<br />1. VERTICAL CURB, GUTTER AND SIDEWALK SHALL CONFORM TO SAN JOAQUIN
<br />COUNTY STANDARD DRAWING NO. R-6.
<br />2. WHEELCHAIR RAMPS SHALL BE CONSTRUCTED AT LOCATIONS SHOWN ON THE
<br />PLANS AND SHALL CONFORM TO SAN JOAQUIN COUNTY STANDARD DRAWING NO.
<br />R -10A & B.
<br />J. EXISTING CURB, GUTTER AND SIDEWALK OUTSIDE THE WORK LIMITS THAT
<br />ARE DAMAGED DURING CONSTRUCTION SHALL BE REPLACED BY THE
<br />CONTRACTOR AT THE CONTRACTOR'S SOLE EXPENSE AND TO THE
<br />SATISFACTION OF THE COUNTY.
<br />4. ALL CEMENT TO BE USED SHALL BE TYPE 11 PORTLAND CEMENT CONFORMING
<br />TO ASTM C150. PORTLAND CEMENT CONCRETE SHALL BE GRADE B AND HAVE
<br />A 28 -DAY MINIMIM COMPRESSIVE STRENGTH OF 2500 PSI. A COPY OF THE
<br />CONCRETE TAGS SHALL BE PROVIDED TO THE CITY ENGINEER FOR EACH
<br />LOAD OF CONCRETE DELIVERED TO THE PROJECT.
<br />5. NEW CONCRETE CURB AND GUTTER SHALL BE TIED TO THE EXISTING
<br />CONCRETE CURB AND GUTTER WITH DOWELS. THE DOWELS SHALL BE N0. 4
<br />REBARS WITH A MI/N/MUM LENGTH OF 12 INCHES. THE DOWELS ARE TO BE
<br />INSERTED TO A MIN/MLM OF 6 INCHES INTO THE EXISTING CONCRETE CURB.
<br />6. THE EXPOSED SURFACES OF THE CURB AND GUTTER SHALL BE BROOM FINISH.
<br />IMMEDIATELY UPON STRIPPING CURB FORMS AND PRIOR TO BACKFILLING,
<br />ALL ROCK POCKETS OR HONEYCOMBS SHALL BE REPAIRED TO THE
<br />SATISFACTION OF THE ENGINEER.
<br />7. DRIVEWAY SHALL BE CONSTRUCTED AT LOCATIONS SHOWN ON THE PLANS
<br />AND SHALL CONFORM TO SAN JOAQUIN COUNTY STANDARD DRAWING NO. R-14.
<br />ASPHALT CONCRETE
<br />1, AGGREGATE SUBBASE SHALL BE CLASS 2 AND SHALL CONFORM TO SECTION
<br />25 OF THE 'STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION
<br />STANDARD SPECIFICATIONS, JULY 1992. ' AGGREGATE BASE SHALL BE
<br />CLASS 2 AND SHALL CONFORM TO SECTION 26 OF THE 'STATE OF
<br />CALIFORNIA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS,
<br />JULY 1992. 'ASPHALT CONCRETE SHALL BE TYPE 'A' 3/4' MAX/MUM,
<br />MEDIUM/ GRADATION AND SHALL CONFORM TO SECTION 39 OF THE STATE OF
<br />CALIFORNIA, DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS,
<br />JULY 1992. '
<br />2. ASPHALT BINDER TO BE MIXED WITH AGGREGATES SHALL BE PAVING
<br />ASPHALT AR -8000 AND SHALL CONFORM TO THE REQUIREMENTS OF SECTION
<br />92, "ASPHALTS' OF THE STATE STANDARD SPECIFICATIONS. AGGREGATE
<br />SHALL BE CLEAN AND FREE FROM DECOMPOSED MATERIALS, ORGANIC
<br />MATERIAL AND OTHER DELETERIOUS SUBSTANCES, AND CONFORMING TO THE
<br />REQUIREMENTS OF SECTION 39-2.02, 'AGGREGATE' OF THE STATE
<br />STANDARD SPECIFICATIONS.
<br />J. CONTRACTOR SHALL PROVIDE CONCRETE MIX DESIGN.
<br />4. PRIOR TO PLACING THE NEW ASPHALT CONCRETE, A TACK COAT SHALL BE
<br />APPLIED TO ALL VERTICAL SURFACES OF EXISTING PAVEMENT, CURBS,
<br />GUTTERS AND CONSTRUCTION JOINTS AGAINST WHICH ADDITIONAL ASPHALT
<br />CONCRETE IS TO BE PLACED. THE RA TE OF APPLICA TION SHALL BE
<br />APPROXIMATELY 0. 10 GALLON PER SQUARE YARD OF SURFACE COVERED.
<br />5. ASPHALT CONCRETE SHALL BE SPREAD AND COMPACTED IN ACCORDANCE WITH
<br />THE REQUIREMENTS OF SECTION 39-5, 'SPREADING AND COMPACTING
<br />EQUIPMENT,' AND SECTION 39-6, "SPREADING AND COMPACTING' OF THE
<br />STATE STANDARD SPECIFICATIONS.
<br />6. PRIOR TO INSTALLATION OF NEW ASPHALT CONCRETE, CONTRACTOR SHALL
<br />COPACT THE BASE ROCK MATERIALS WITH A VIBRATING ROLLER OR WITH A
<br />MECHANICAL TAMPER TO OBTAIN A M/NIA" OF 95% COMPACTION. THE
<br />SURFACE OF THE FINISHED AGGREGATE BASE AT ANY POINT SHALL NOT
<br />VARY MORE THAN 0.05 FOOT ABOVE OR BELOW THE GRADE ESTABLISHED ON
<br />THE PLANS. THE SPREADING AND COMPACTING OF AGGREGATE BASE SHALL
<br />CONFORM TO THE REQUIREMENTS OF SECTION 26-1.035, 26-1.04 AND
<br />26-1.05 OF THE STATE STANDARD SPECIFICATIONS.
<br />7. EXISTING PAVEMENT OUTSIDE THE WORK LIMITS DAMAGED DURING
<br />CONSTRUCTION SHALL BE REPLACED BY AN EQUAL SECTION TO THE
<br />SATISFACTION OF THE COUNTY.
<br />8. EXISTING AC PAVEMENT SHALL BE SAWCUT ALONG THE PROPOSED EDGE OF
<br />REMOVAL TO PROVIDE A NEAT CONFORM TO THE EXISTING AC PAVEMENT.
<br />9. AT THE TIME OF DELIVERY OF EACH SHIPMENT OF ASPHALT, THE VENDOR
<br />SUPPLYING THE MATERIAL WILL PROVIDE CERTIFIED COPIES OF TEST
<br />REPORT. THE TEST REPORT SHALL CONFORM TO THE REQUIREMENTS OF
<br />SECTION 92-1.OJ, 'TEST REPORT'OF THE STATE STANDARD SPECIFICATIONS,
<br />STREET LIGHTS
<br />1. ALL STREET LIGHTS SHALL BE CONSTRUCTED TO SAN JOAQUIN COUNTY
<br />STANDARD R-32, R-33 AND R-34.
<br />2. LUMINA/RES SHALL BE 150 WATT, HIGH PRESSURE SODIUM FOR STREET
<br />LIGHTS DN SCHULTE ROAD, STANFORD ROAD & BERKELEY ROAD AND 250
<br />WATT FOR THE LIGHTS ON PATTERSON PASS ROAD.
<br />SIGNING AND STRIPING
<br />1. TRAFFIC SIGNS SHALL BE INSTALLED AT LOCATIONS SPECIFIED ON THE
<br />PLANS, IN ACCORDANCE WITH THE REQUIREMENTS OF CAL TRANS TRAFFIC
<br />AIANUAL , LATEST EDITION.
<br />2. PA VEAENT STRIPING SHALL INCLUDE STOP BARS, CENTERLINE STRIPING
<br />OR MARKERS, CROSSWALKS AND ALL OTHER MARKINGS REQUIRED BY THE
<br />COUNTY AND AS SHOWN ON THESE PLANS. STRIPING SHALL BE DONE WITH
<br />HOT APPLIED THERMOPLASTIC AND REFLECTIVE MARKERS CONFORMING TO
<br />THE REQUIREMENTS OF SECTION 84 & 85 OF CAL TRANS SPECIFICATIONS.
<br />J. EXISTING STRIPING PROPOSED TO BE REMOVED SHALL BE DONE BY
<br />SANDBLASTING.
<br />4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING EXISTING STRIPING,
<br />MARKING OR LEGENDS AS NECESSARY PRIOR TO PLACING THE NEW STRIPING,
<br />MARKING AND LEGENDS AS SHOWN DN THE SIGNING AND STRIPING PLAN TO
<br />A VOID CONFLICTS.
<br />EROSION CONTROL NOTES
<br />i. EROSION AND SEDIMENT CONTROL MEASURES SHALL BE EFFECTIVE FOR
<br />CONSTRUCTION DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 1).
<br />2. NO STORM RUNOFF WATER SHALL BE ALLOWED TO DRAIN DIRECTLY INTO THE
<br />EXISTING UNDERGROUND STORM SYSTEM, THE CALIFORNIA AQUEDUCT OR THE
<br />DEL TA MENDOTA CANAL BEFORE THE ONSITE STORiM DRAIN SYSTEM IS
<br />INSTALLED.
<br />J. AS SOON AS IS PRACTICAL AFTER THE NEW STORM SYSTEM IS INSTALLED,
<br />THE CATCH BASINS SHALL BE INSTALLED AND STRAW BALES SHALL BE
<br />PLACED AROUND THE CATCH BASINS.
<br />4. SHOULD THE PROPOSED ONSITE STORM SYSTEM NOT BE INSTALLED BY
<br />OCTOBER 1, TEMPORARY SEDIMENT BASINS SHALL BE CONSTRUCTED AROUND
<br />THE OPENINGS OF ANY EXISTING STORM PIPES WHICH DRAIN THE SITE.
<br />5. THE NAME, ADDRESS AND 24 HOUR TELEPHONE NUMBER OF THE PERSON
<br />RESPOIVS1 BLE FOR IMPLEMENTATION OF THE EROSION AND SEDIMENTATION
<br />CONTROL PLAN SHALL BE PROVIDED TO THE COUNTY.
<br />6. ALL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE
<br />MAINTAINED UNTIL DISTURBED AREAS ARE STABILIZED. CHANGES TO THE
<br />EROSION AND SEDIMENTATION CONTROL PLAN SHALL BE MADE TO MEET
<br />FIELD CONDITIONS, BUT ONLY WITH THE APPROVAL OF OR AT THE
<br />DIRECTION OF THE COUNTY PUBLIC WORKS DIRECTOR.
<br />7. DURING THE RAINY SEASON SPECIFIED IN NOTE 1 ALL PAVED AREAS SHALL
<br />BE KEPT CLEAR OF EARTH MATERIALS AND DEBRIS. THE SITE SHALL BE
<br />MAINTAINED SO AS TO MINIMIZE SEDIMENT LADEN RUNOFF FROM ENTERING
<br />ANY STORM DRAINAGE SYSTEM.
<br />8. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSPECT AND REPA I R
<br />ALL EROSION CONTROL FACILITIES AT THE END OF EACH WORK DAY DURING
<br />THE RA/NY SEASON.
<br />9. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT TEMPORARY
<br />BARROW AREAS AND/OR STOCKPILES WITH APPROPRIATE EROSION CONTROL
<br />MEASURES SATISFACTORY TO THE COUNTY PUBLIC WORKS DIRECTOR.
<br />10. ALL EROSION CONTROL DEVICES SHALL BE REMOVED AND DISPOSED OF BY
<br />THE CONTRACTOR UPON COMPLETION OF THE PROJECT.
<br />11. CONTRACTOR SHALL TAKE MEASURES NECESSARY TO PROHIBIT NON -STORM
<br />WATER DISCHARGES FROM ENTERING THE STORM SYSTEM OR ADJACENT
<br />WATERWAY (I.E. CLEANING OF EQUIPMENT, WASHING OF STREETS AND
<br />STORAGE OF EXCESS MATERIALS).
<br />LIST OF CONTACTS
<br />OWMER
<br />DESIGN ENGINEER
<br />TRAFFIC ENGINEER
<br />TELEPHONE
<br />STREETS -STORM DRAIN
<br />TRAFFIC SIGNALS
<br />GAS - ELECTRICITY
<br />SANITARY SEWER
<br />WATER
<br />KING & LYONS
<br />47775 FREMONT BLVD.
<br />FREMONT, CA 94538
<br />(510) 656-1900
<br />RUGGERI-JENSEN-AZAR & ASSOCS.
<br />6601 OWENS DR., ,/155
<br />PLEASANTON, CA 94588
<br />(510) 227-9100
<br />CCS
<br />42080 OSGOOD ROAD, SUITE 1
<br />FREMONT, CA 94539
<br />(510) 656-7091
<br />PACIFIC BELL
<br />44 W. YOKUTS AVE.
<br />STOCKTON, CA 95207
<br />(209) 474-4742
<br />SAN JOAQUIN COUNTY
<br />1810 HAZEL TON AVE.
<br />STOCKTON, CA. 95207
<br />(209) 468-3120
<br />PG&E
<br />55 E. TENTH ST
<br />TRACY, CA. 95376
<br />(209) 836-0440
<br />CITY OF TRACY
<br />520 TRACY BLVD.
<br />TRACY, CA. 95376
<br />(209) 831-4420
<br />Cl TY OF TRACY
<br />520 TRACY BLVD.
<br />TRACY, CA. 95376
<br />(209) 831--4420
<br />Z
<br />W
<br />U
<br />W
<br />�
<br />Q
<br />H
<br />Q
<br />Z
<br />N
<br />O
<br />Z ~
<br />LL
<br />.j
<br />CL W<_
<br />cl)>
<br />Q
<br />U
<br />CL
<br />LL, Co
<br />W
<br />�-
<br />20)~
<br />WW
<br />Z
<br />OV
<br />0
<br />mjzj
<br />CL
<br />0
<br />�N
<br />O
<br />Q
<br />a
<br />Z
<br />O
<br />Q
<br />�z
<br />O
<br />W
<br />H
<br />F_
<br />z
<br />Q
<br />a
<br />]L
<br />O
<br />0
<br />z
<br /><� <``
<br />�W
<br />t� a
<br />w
<br />m
<br />w
<br />SHEET NO.
<br />2
<br />OF 39 SHEETS
<br />JOB NO.
<br />951064
<br />
|