Laserfiche WebLink
Printed on:Tuesday 08/22/2023 09:16 AM 29C0115/AAAJ/111943Pageof4 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />6 <br />Photo 4 <br />Typical condition of the AC overlay. Span 1 shown <br /> DECK PHOTOGRAPHS <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition State <br />Deck Wearing Surface-Asphalt <br />Cracking-AC (WS) <br />2 <br />2 <br />174 <br />35 <br />sq.m <br />each <br /> 139 <br /> 0 <br /> 35 <br /> 35 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />DECK ELEMENT INSPECTION RATINGS AND NOTES <br />Defect/ <br />Prot <br />510 <br />Defect <br />3220 <br />(38) Slab-RC <br />(38-510-3220) Cracking-AC (WS) <br />There is AC overlay present throughout the RC slab surface except for sections 18 inches wide at the edges of the RC slab. <br />No significant defects were observed. <br />There are transverse cracks up to 0.125 inches wide spaced as close as 6 inches on center through-out the AC overlay. See Photo <br />4. <br />(58) 7DECK RATING = <br />(36a) Rail Code 0000 <br />330 Railing-Metal 2 44 m 44 0 0 0 <br />JOINT/APPROACH/RAIL ELEMENT INSPECTION RATINGS AND NOTES <br />RAIL INFORMATION <br />(36b) Transition (36c) Appr Guardrail (36d) Appr Guardrail End 55Roadway Speed MPH <br />JOINT - APPROACH - RAIL <br />(330) Railing-Metal <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />There were no significant defects noted.