Laserfiche WebLink
Printed on:Tuesday 08/22/2023 09:21 AM 29C0130/AAAN/105927Pageof5 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />7 <br />DESCRIPTION UNDER STRUCTURE <br />CHANNEL DESCRIPTION <br />Natural earth. <br />SUBSTRUCTURE PHOTOGRAPHS <br />TYPE OF SERVICE UNDER <br />N NOT APPLICABLE (NBI)UNDERCLEARANCES V - H <br />8 EQUAL DESIRABLEWATER ADEQUACY <br /> MVERT-LIFT BRIDGE NAV MIN VERTICAL CLEAR <br />NAVIGATION CONTROL <br />0.0 MNAVIGATION HORIZONTAL CLEARANCE <br />0.0 MNAVIGATION VERTICAL CLEARANCE <br />PIER PROTECTION <br />0: NO CONTROL5-WATERWAY <br />5 STABLE W/IN FOOTING OR PILESCOUR <br />N/ASCOUR POA DATE <br />CHANNEL PROTECTION 5 BANK PROT ERODED <br />N/A <br />(42b) <br />(69) <br />(71) <br />(61) <br />(113) <br />(38) <br />(111) <br />(39) <br />(116) <br />(40) <br />SUPERSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES - NONE <br />205 <br />215 <br />252 <br />Column-RC <br />Abutment-RC <br />Pile-CIDH <br />Scour <br />2 <br />2 <br />2 <br />2 <br />10 <br />40 <br />10 <br />10 <br />each <br />m <br />ea. <br />each <br /> 10 <br /> 40 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 10 <br /> 10 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />SUBSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br /> 0 <br /> 0 <br /> 0 <br /> 06000 <br />SUPERSTRUCTURE <br />SUBSTRUCTURE <br />SUPERSTRUCTURE RATING =(59) 7 <br />SUBSTRUCTURE RATING =(60)7 <br />(205) Column-RC <br />(215) Abutment-RC <br />(252-6000) Scour <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />There were no significant defects noted. <br />The monolithic wingwalls has been included with the quantity. <br />There were no significant defects noted. <br />The CIDH RC piles at the bents are exposed. The exposure was measured on the Span 2 side of the bents as follows: <br />*Bent 2 - 12 to 16 inches. See Photo 4 dated 03/09/2021. <br />*Bent 3 - 10 to 14 inches. See Photo 5 dated 03/09/2021. <br />This condition has been previously reported and no significant changes were noted. <br />(36a) Rail Code 0000 <br />330 Railing-Metal 2 53 m 53 0 0 0 <br />JOINT/APPROACH/RAIL ELEMENT INSPECTION RATINGS AND NOTES <br />RAIL INFORMATION <br />(36b) Transition (36c) Appr Guardrail (36d) Appr Guardrail End 55Roadway Speed MPH <br />JOINT - APPROACH - RAIL <br />(330) Railing-Metal <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />The bridge rails are galvanized. <br />There were no significant defects noted.