My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2024-29C-307
PublicWorks
>
ArcGIS Online
>
Bridges
>
29C-307
>
2024-29C-307
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/3/2025 11:54:08 AM
Creation date
6/3/2025 11:53:57 AM
Metadata
Fields
Template:
Supporting Docs - Bridge
Bridge #
29C-307
Type - Bridge Supporting Doc
Inspection
Name
Duck Creek Branch - Buckman Road
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Printed on:Thursday 02/27/2025 11:46 AM 29C0307/AAAU/148025Pageof4 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />8 <br />TYPE OF MEMBRANE <br />TYPE OF DECK PROTECTION <br />DECK STRUCTURE TYPE <br />TYPE OF WEARING SURFACE <br />WEARING SURFACE / PROTECTIVE SYSTEM <br />13AVERAGE DAILY TRAFFIC <br />2015 YEAR OF ADT <br />199 KMBYPASS, DETOUR LENGTH <br />3 %(109) TRUCK ADT % <br />32FUTURE ADT <br />2046YEAR OF FUTURE ADT <br />HISTORICAL SIGNIFICANCE 5: NOT ELIGIBLE FOR NRHP <br />6-BITUMINOUS <br />0-NONE <br />0-NONE <br />8-TIMBER <br />DECK STRUCTURE INFORMATION <br />5.8 M <br />5.6 M <br />DECK AND ROADWAY <br />LANES 1 <br />40 <br />0-NOT ON NHS <br />PARALLEL STRUCTURE <br />TEMPORARY STRUCTURE <br />DEFENSE HIGHWAY <br />FUNCTIONAL CLASS <br />SPEED <br />NATIONAL HIGHWAY SYSTEM <br />TOLL <br />DIRECTION OF TRAFFIC <br />DESIGNATED NATIONAL NETWORK <br />TYPE OF SERVICE <br />FEDERAL LANDS HWY <br />6 EQUAL MIN CRITERIAAPPR ROADWAY ALIGN <br />4 TOLERABLEDECK GEOMETRY <br />5.6 MAPPROACH RDWY WIDTH <br />BRIDGE MEDIAN <br />LEFT 0.0 M RIGHT 0.0 MCURB OR SIDEWALK <br />TOTAL WIDTH <br />NET WIDTH <br />5.6 MINVENTORY ROUTE TOTAL HORIZ CLEAR <br />99.99 MINVENTORY ROUTE MIN VERT CLEAR <br />3-ON FREE ROAD <br />09-LOCAL RURAL <br />0-NOT STRAHNET <br />N-NONE EXISTS <br />3-1 LANE, 2 WAY <br />0-NOT APPLICABLE <br />0-NOT ON NET <br />0 NO MEDIAN <br />1-HIGHWAY <br />DECK ROADWAY/OPERATIONAL INFORMATIONDECK GEOMETRY <br />0.33 ft br, 18.33 ft, 0.33 ft br <br />DECK CROSS SECTION <br />LRS INVENTORY RTE & SUBRTE <br />BASE HIGHWAY NETWORK 0-NOT ON NET <br />3 inchesOVERLAY THICKNESS (inches) <br />N/A <br />(51) <br />(52) <br />(50) <br />(32) <br />(33) <br />(107) <br />(108) <br />A) <br />B) <br />C) <br />(29) <br />(30) <br />(19) <br />(114) <br />(115) <br />(37) <br />(42a) <br />(12) <br />(13) <br />(104) <br />(26) <br />(100) <br />(101) <br />(102) <br />(10) <br />(47) <br />(68) <br />(72) <br />(105) <br />(110) <br />(20) <br />(28a) <br />(103) <br />12.5 MLENGTH (49) <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition State <br />31 Deck-Timber <br />Decay/Section Loss (Timber) <br />Deck Wearing Surface-Asphalt <br />2 <br />2 <br />2 <br />73 <br />20 <br />73 <br />sq.m <br />each <br />sq.m <br /> 53 <br /> 0 <br /> 73 <br /> 15 <br /> 15 <br /> 0 <br /> 5 <br /> 5 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />DECK ELEMENT INSPECTION RATINGS AND NOTES <br />Defect/ <br />Prot <br />1140 <br />510 <br />Defect <br />(31) Deck-Timber <br />(31-1140) Decay/Section Loss (Timber) <br />(31-510) Deck Wearing Surface-Asphalt <br />New treated timber decking was installed in Span 1. See Photo 2. <br />During the repairs of the split and rotten girders in January 2018, new timber decking was installed in Span 3. See Photo 7 dated <br />11/08/2018. <br />The left and right edges of the timber planks in Span 2 are soft when probed with an awl and are decayed on the edges. This decay <br />extends up to 3 feet along the bottom of the planks and is up to 0.25 inches deep. See Photo 6 dated 11/10/2023) <br />White fungus was randomly distributed on approximately 40% of the soffit of the timber deck in Span 2. See Photo 3. <br />These conditions have been previously reported and no significant changes were noted. <br />New treated timber decking was installed in Span 1, new AC overlay was applied in all spans. See Photo 1. <br />There were no significant defects noted. <br />(58) 6DECK RATING =
The URL can be used to link to this page
Your browser does not support the video tag.