Printed on:Tuesday 10/18/2022 01:44 PM 29C0370/AAAP/90688Pageof3 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />6 <br />UNDERWATER INVESTIGATION DETAILS <br />STEEL INVESTIGATION DETAILS <br />SCOPE AND ACCESS <br />The aqueduct was flowing under both spans approximately 8 feet below the bottom of the exterior girders. The abutments were dry and <br />the soffit and superstructure were observed from the canal banks. A complete routine inspection was performed on all of the visible <br />elements by walking on and about the structure. <br />The submerged portions of Pier 2 are inspected by the Caltrans Underwater Inspection Team. The most recent underwater investigation <br />was performed on 02/14/2018. All identified defects from that inspection have been incorporated into the condition states of the respective <br />elements and have been described in the element or defect notes. Refer to the 02/14/2018 underwater inspection report for further detail. <br />NUMBERING CONVENTION <br />The numbering system used on the as-built plans for this structure is reversed from the convention employed by Structure Maintenance <br />& Investigations. This report and all subsequent reports will follow the SM&I numbering convention with Abutment 1 designated as the <br />south abutment. <br />MISCELLANEOUS <br />New routine photos were taken and a new routine map view photo was added during this investigation. See Photos 1 to 4. <br />INSPECTION COMMENTARY <br />TYPE OF MEMBRANE <br />TYPE OF DECK PROTECTION <br />DECK STRUCTURE TYPE <br />TYPE OF WEARING SURFACE <br />WEARING SURFACE / PROTECTIVE SYSTEM <br />3491AVERAGE DAILY TRAFFIC <br />2009 YEAR OF ADT <br />6 KMBYPASS, DETOUR LENGTH <br />50 %(109) TRUCK ADT % <br />4278FUTURE ADT <br />2040 YEAR OF FUTURE ADT <br />HISTORICAL SIGNIFICANCE 5: NOT ELIGIBLE FOR NRHP <br />0-NONE <br />0-NONE <br />0-NONE <br />1-CIP CONCRETE <br />DECK STRUCTURE INFORMATION <br />10.4 M <br />9.8 M <br />DECK AND ROADWAY <br />LANES 2 <br />55 <br />0-NOT ON NHS <br />PARALLEL STRUCTURE <br />TEMPORARY STRUCTURE <br />DEFENSE HIGHWAY <br />FUNCTIONAL CLASS <br />SPEED <br />NATIONAL HIGHWAY SYSTEM <br />TOLL <br />DIRECTION OF TRAFFIC <br />DESIGNATED NATIONAL NETWORK <br />TYPE OF SERVICE <br />FEDERAL LANDS HWY <br />8 EQUAL DESIRABLE CRITAPPR ROADWAY ALIGN <br />4 TOLERABLEDECK GEOMETRY <br />9.8 MAPPROACH RDWY WIDTH <br />BRIDGE MEDIAN <br />LEFT 0.3 M RIGHT 0.3 MCURB OR SIDEWALK <br />TOTAL WIDTH <br />NET WIDTH <br />9.8 MINVENTORY ROUTE TOTAL HORIZ CLEAR <br />99.99 MINVENTORY ROUTE MIN VERT CLEAR <br />3-ON FREE ROAD <br />08-MINOR COLLECTOR RURAL <br />0-NOT STRAHNET <br />N-NONE EXISTS <br />2-2 WAY <br />0-NOT APPLICABLE <br />0-NOT ON NET <br />0 NO MEDIAN <br />1-HIGHWAY <br />DECK ROADWAY/OPERATIONAL INFORMATIONDECK GEOMETRY <br />1 ft br & cu, 32 ft, 1 ft cu & br <br />DECK CROSS SECTION <br />LRS INVENTORY RTE & SUBRTE <br />BASE HIGHWAY NETWORK 0-NOT ON NET <br />1 - FreshWater TypeB - Routine UWDive Type <br />Next UWI 02/14/2024UWI Frequency months 72UWI Required Y Last UWI 02/14/2018 <br />- NOT APPLICABLE FOR THIS BRIDGE. <br />0 inchesOVERLAY THICKNESS (inches) <br />N/A <br />(51) <br />(52) <br />(50) <br />(32) <br />(33) <br />(107) <br />(108) <br />A) <br />B) <br />C) <br />(29) <br />(30) <br />(19) <br />(114) <br />(115) <br />(37) <br />(42a) <br />(12) <br />(13) <br />(104) <br />(26) <br />(100) <br />(101) <br />(102) <br />(10) <br />(47) <br />(68) <br />(72) <br />(105) <br />(110) <br />(20) <br />(28a) <br />(103) <br />CONDITION INFORMATION <br />46.9 MLENGTH (49) <br />Elem Env Total Units Qty in each Condition State <br />DECK ELEMENT INSPECTION RATINGS AND NOTES <br />Defect/ <br />(58) 4DECK RATING = <br />SPECIAL INSPECTION INFORMATION