Laserfiche WebLink
Printed on:Thursday 10/03/2024 11:48 AM 29C0374/AAAO/136927Pageof5 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />7 <br />110 Girder/Beam-RC 2 39 m 39 0 0 0 <br />SUPERSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br />SUPERSTRUCTURE <br />SUPERSTRUCTURE RATING =(59) 7 <br />(110) Girder/Beam-RC <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />There are a few vertical hairline cracks spaced up to 14 inches on center in the girders. A defect is not warranted at this time. <br />There are some drilled holes in the top of the exterior girders located approximately 8 inches below the soffit randomly spaced. This <br />condition is from the construction of the new barrier rails and no defect is warranted at this time. See Photo 7. <br />JOINT - APPROACH - RAIL <br />Photo 2 <br />Depressed AC approach at Abutment 1. Looking northwest <br />Photo 3 <br />Pothole in the AC in the northbound lane at the bridge interface <br />at Abutment 1 <br />Photo 4 <br />Pothole in the AC in the north & southbound lanes at the bridge <br />interface at Abutment 2 <br />JOINT/APPROACH/RAIL PHOTOGRAPHS