Printed on:Thursday 10/03/2024 11:48 AM 29C0383/AAAP/136927Pageof5 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />7 <br />DESCRIPTION UNDER STRUCTURE <br />CHANNEL DESCRIPTION <br />RC-lined channel. <br />Photo 8 <br />Typical vertical cracks in the diaphragm between girders. <br />Abutment 1 Bay 3 shown <br /> SUPERSTRUCTURE PHOTOGRAPHS <br />TYPE OF SERVICE UNDER <br />N NOT APPLICABLE (NBI)UNDERCLEARANCES V - H <br />9 ABOVE DESIRABLEWATER ADEQUACY <br /> MVERT-LIFT BRIDGE NAV MIN VERTICAL CLEAR <br />NAVIGATION CONTROL <br />0.0 MNAVIGATION HORIZONTAL CLEARANCE <br />0.0 MNAVIGATION VERTICAL CLEARANCE <br />PIER PROTECTION <br />0: NO CONTROL5-WATERWAY <br />8 STABLE ABOVE FOOTINGSCOUR <br />N/ASCOUR POA DATE <br />CHANNEL PROTECTION 8 PROTECTED <br />N/A <br />(42b) <br />(69) <br />(71) <br />(61) <br />(113) <br />(38) <br />(111) <br />(39) <br />(116) <br />(40) <br />SUPERSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br />210 <br />215 <br />Pier Wall-RC <br />Abrasion (PS Conc./RC) <br />Abutment-RC <br />Cracking (RC and Other) <br />2 <br />2 <br />2 <br />2 <br />20 <br />20 <br />49 <br />8 <br />m <br />each <br />m <br />each <br /> 0 <br /> 0 <br /> 41 <br /> 0 <br /> 20 <br /> 20 <br /> 8 <br /> 8 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />SUBSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />1190 <br />1130 <br />SUPERSTRUCTURE <br />SUBSTRUCTURE <br />SUPERSTRUCTURE RATING =(59) (6) <br />SUBSTRUCTURE RATING =(60)(6) <br />(110-1130) Cracking (RC and Other) <br />(210) Pier Wall-RC <br />(210-1190) Abrasion (PS Conc./RC) <br />(215) Abutment-RC <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />Non-Routine Inspection Element Notes: <br />Non-Routine Inspection Element Notes: <br />UWI (02/13/2024): No ELI changes. <br />UWI (02/13/2024): Pier walls show abrasion, exposing secure course aggregate, and 20 meters will remain in CS2. No ELI changes. <br />There are diagonal and vertical cracks up to 0.02 inches wide spaced as close as 12 inches on center in the girders within the first 10 <br />feet from the abutments. (See Photo 5 dated 06/08/2022). This condition has been previously reported and no significant changes <br />were noted.