Laserfiche WebLink
Printed on:Wednesday 04/30/2025 02:29 PM 29C0105/AAAO/151727Pageof4 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />6 <br />Photo 1 <br />Typical longitudinal deck cracks near the abutments. Abutment <br />4 shown <br /> DECK PHOTOGRAPHS <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition State <br />Cracking (RC and Other) <br />Deck Wearing Surface-Asphalt <br />Cracking-AC (WS) <br />Effectiveness (WS) <br />2 <br />2 <br />2 <br />2 <br />372 <br />424 <br />275 <br />85 <br />each <br />sq.m <br />each <br />each <br /> 0 <br /> 64 <br /> 0 <br /> 0 <br /> 372 <br /> 275 <br /> 275 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 85 <br /> 0 <br /> 85 <br />DECK ELEMENT INSPECTION RATINGS AND NOTES <br />Defect/ <br />Prot <br />1130 <br />510 <br />Defect <br />3220 <br />3230 <br />(16) Top Flange-RC <br />(16-1120) Efflorescence/Rust Staining <br />(16-1130) Cracking (RC and Other) <br />(16-510-3220) Cracking-AC (WS) <br />(16-510-3230) Effectiveness (WS) <br />Smoke staining was observed on the soffit of Span 3. No defects were noted in this area. <br />There are hairline diagonal cracks with light efflorescence and brown stains approximately 18 inches on center in soffit of all the bays <br />near the supports. (See Photo 3 dated 02/17/2021). This condition has been previously reported and no significant changes were <br />noted. <br />There are transverse cracks up to 0.02 inches wide spaced 12 inches on center in the bare shoulders of the deck. These cracks <br />translate into the AC overlay and were observed on the deck surface where the AC overlay has worn off. See Photos 5 and 6 dated <br />02/09/2023. <br />There are longitudinal cracks up to 0.02 inches wide were observed on the deck surface where the AC overlay has worn off near the <br />abutments. See Photo 1. <br />These conditions have been previously reported and no significant changes were noted. <br />There are reflective full width transverse cracks up to 0.125 inches wide spaced 12 inches on center in the AC overlay. (See Photo 6 <br />dated 02/09/2023). This condition has been previously reported and no significant changes were noted. <br />The thin AC overlay has worn throughout the deck, generally in the center of both lanes and at both abutments. This accounts for <br />approximately 20% of the AC area. (See Photo 2 dated 02/17/2021). This condition has been previously reported and no significant <br />changes were noted. <br />(58) 6DECK RATING = <br />(36a) Rail Code 0000 <br />JOINT/APPROACH/RAIL ELEMENT INSPECTION RATINGS AND NOTES <br />RAIL INFORMATION <br />(36b) Transition (36c) Appr Guardrail (36d) Appr Guardrail End 55Roadway Speed MPH <br />JOINT - APPROACH - RAIL <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect