Laserfiche WebLink
Department of Transportation - Division of Maintenance <br />Structure Maintenance & Investigations <br />INSPECTION COMMENTARY <br />West Gates Lower Raise <br />On -Coming Gate damaged <br />Off -Going 3.4 7.2 Amps <br />East Gates Lower Raise <br />On -Coming 3.9 Amps 3.2 Amps <br />Off -Going 3.8 Amps 3.6 Amps <br />PERSONNELPRESENT <br />Mike Shelton, Bridge Maintenance <br />Chris Juardo (operator) <br />County Contact: <br />Jeffery Verstl jverstl@sjgov.org (209) 953-7600 <br />(209) 468-0380 Bridge Engineering Division <br />Davin Parker Maintenance Manager (209) 468-3074 (dparker@sjgov.org) <br />Public Works Department San Joaquin County <br />(209) 953-7600 <br />STEEL INVESTIGATION DETAILS - NOT APPLICABLE FOR THIS BRIDGE. <br />UNDERWATER INVESTIGATION DETAILS <br />UWI Required Y Last UWI 05/05/2023 <br />Dive Type B - Routine UW <br />DECK CROSS SECTION <br />1.3 ft br, 36.0 ft to 43.0 ft (varies), 1.3 ft br <br />DECK GEOMETRY <br />(49) LENGTH <br />(51) NET WIDTH <br />(52) TOTAL WIDTH <br />(50) CURB OR SIDEWALK LEFT 0.0 M <br />(32) APPROACH RDWY WIDTH <br />(33) BRIDGE MEDIAN <br />DECK STRUCTURE INFORMATION <br />(107) DECK STRUCTURE TYPE <br />(108) WEARING SURFACE / PROTECTIVE SYSTEM <br />A) TYPE OF WEARING SURFACE <br />B) TYPE OF MEMBRANE <br />C) TYPE OF DECK PROTECTION <br />OVERLAY THICKNESS (inches) <br />(29) AVERAGE DAILY TRAFFIC <br />(30) YEAR OF ADT 2015 <br />(19) BYPASS, DETOUR LENGTH <br />(114) FUTURE ADT <br />(115) YEAR OF FUTURE ADT <br />(37) HISTORICAL SIGNIFICANCE <br />UWI Frequency 60 months <br />Water Type 3 - Brackish <br />97.5 M <br />11.0 M <br />11.8 M <br />RIGHT 0.0 M <br />11.0 M <br />0 NO MEDIAN <br />1-CIP CONCRETE <br />0-NONE <br />0-NONE <br />0-NONE <br />0 inches <br />1000 <br />(109) TRUCK ADT % 3 % <br />199 KM <br />5379 <br />2042 <br />5: NOT ELIGIBLE FOR NRHP <br />Next UWI 05/05/2028 <br />DECK ROADWAY/OPERATIONAL INFORMATION <br />(42a) TYPE OF SERVICE <br />1-HIGHWAY <br />(12) BASE HIGHWAY NETWORK <br />0-NOT ON NET <br />(13) LRS INVENTORY RTE & SUBRTE <br />(104) NATIONAL HIGHWAY SYSTEM <br />0-NOT ON NHS <br />(26) FUNCTIONAL CLASS 07-MAJOR COLLECTOR RURAL <br />(100) DEFENSE HIGHWAY <br />0-NOT STRAHNET <br />(101) PARALLEL STRUCTURE <br />N-NONE EXISTS <br />(102) DIRECTION OF TRAFFIC <br />2-2 WAY <br />(10) INVENTORY ROUTE MIN VERT <br />CLEAR 99.99 M <br />(47) INVENTORY ROUTE TOTAL HORIZ CLEAR 11.0 M <br />(68) DECK GEOMETRY <br />7 ABOVE MIN CRITERIA <br />(72) APPR ROADWAY ALIGN <br />6 EQUAL MIN CRITERIA <br />(105) FEDERAL LANDS HWY <br />0-NOT APPLICABLE <br />(110) DESIGNATED NATIONAL NETWORK 0-NOT ON NET <br />(20) TOLL <br />3-ON FREE ROAD <br />(28a) LANES <br />2 <br />SPEED <br />45 <br />(103) TEMPORARY STRUCTURE <br />N/A <br />RAIL INFORMATION <br />(36a) Rail Code 1 (36b) Transition 1 (36c) Appr Guardrail 0 (36d) Appr Guardrail End 0 Roadway Speed 45 MPH <br />Printed on: Monday 06/23/2025 03:37 PM Page 5 of 9 29C0114/AAAZ/153158 <br />