My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
29C0131_AABI_2025-MAY
PublicWorks
>
ArcGIS Online
>
Bridges
>
29C-131
>
29C0131_AABI_2025-MAY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 3:24:48 PM
Creation date
7/2/2025 3:23:49 PM
Metadata
Fields
Template:
Supporting Docs - Bridge
Bridge #
29C-131
Type - Bridge Supporting Doc
Inspection
Name
Mokelumne River (Millers Ferry) - Walnut Grove Road
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Department of Transportation - Division of Maintenance <br />Structure Maintenance & Investigations <br />MECHANICAL/ELECTRICAL ELEMENT INSPECTION RATINGS AND NOTES <br />Elem Defect/ Element Description <br />No. Prot Defect <br />Env Total Units Qty in each Condition State <br />Qty CS 1 CS 2 CS 3 CS 4 <br />(605) Drive System - Electrical <br />Non -Routine Inspection Element Notes: <br />The electrical drive system consists of a main drive motor and wedge motor located at the center pivot pier. An end jack motor is <br />located at each end of the span. <br />(605-9002) Wear(Electrical) <br />Non -Routine Inspection Element Notes: <br />Mech/Elect (06/02/2021) All drive motors (Main, Wedge, & End Jack) exibit minor corrosion. The wedge drive motor operates <br />normally. The motor insulation resistance value measures less than 50% below the minimum recommended by NETA <br />(5/9/2023) Condition still present. <br />(5/13/25) Condition still present. <br />606 Control System - Mechanical 2 1 ea. 1 0 0 0 <br />(606) Control System - Mechanical <br />Non -Routine Inspection Element Notes: <br />Chains. <br />607 Control System - Electrical 2 1 ea. 0 1 0 0 <br />9005 Accessibility and Labeling 2 1 ea. 0 1 0 0 <br />(607) Control System - Electrical <br />Non -Routine Inspection Element Notes: <br />Bridge control systems are located in a control panel over the pivot pier on the south side of the roadway and under the span on the <br />center pivot pier. Traffic signals and gates are located in a control panel at the southeast corner of the bridge. <br />(607-9005) Accessibility and Labeling <br />Non -Routine Inspection Element Notes: <br />Mech/Elect (06/02/2021) Some control panels are either missing labels or have labels that are fading. Some control panels exhibit <br />minor corrosion. <br />(5/9/2023) Condition still present. <br />608 Interlocking System - Mechanical 2 1 ea. 1 0 0 0 <br />(608) Interlocking System - Mechanical <br />Non -Routine Inspection Element Notes: <br />See notes in Element 604. <br />609 Interlocking System - Electrical 2 1 ea. 1 0 0 0 <br />(609) Interlocking System - Electrical <br />Non -Routine Inspection Element Notes: <br />The interlocking system consists of limit switches that regulate the sequence of the traffic equipment and movable span operation. <br />610 Pier Protection - Structural 2 1 ea. 1 0 0 0 <br />(610) Pier Protection - Structural <br />Non -Routine Inspection Element Notes: <br />The navigation channel is in Span 2. The pier protection consists of 3 timber dolphins upstream of Pier 2 and 2 timber dolphins <br />downstream. There is also at timber dolphin along the channel bank on each side of Abutment 3. <br />The dolphins (total 7) appear in good condition and there was no drift accumulating at the dolphins or the pier. <br />611 Nav Guidance System - Electrical 2 1 ea. 0 1 0 0 <br />9000 Operation 2 1 ea. 0 1 0 0 <br />(611) Nav Guidance System - Electrical <br />Non -Routine Inspection Element Notes: <br />Navigation lights required by Coast Guard regulation are mounted on dolphins, two upstream and two downstream of Pier 2 and one <br />on each side of Abutment 3. <br />(611-9000) Operation <br />Non -Routine Inspection Element Notes: <br />Mech/Elect (06/02/2021) One of the navigation lights is burned out. <br />(5/9/2023) Condition still present. <br />612 Power System - Electrical 2 1 ea. 0 0 0 1 <br />9005 Accessibility and Labeling 2 1 ea. 0 0 0 1 <br />Printed on: Monday 06/23/2025 03:35 PM Page 6 of 8 29C0131/AABI/153160 <br />
The URL can be used to link to this page
Your browser does not support the video tag.