My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2013_PS-1302501 thru PS-1303000_ - PS-1302902
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2013
>
PS-1302501 thru PS-1303000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2013_PS-1302501 thru PS-1303000_ - PS-1302902
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 4:20:38 PM
Creation date
12/30/2015 6:29:36 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-1302902
Category07
Encroachment(EP)/Driveway(DW) Permits
SubCategory07
2013\PS-1302501 thru PS-1303000
Year2
2013
Supplemental fields
Applicant
APEX ENVIROTECH INC.
Contracts
CrossReference
Description
ENCROACHMENT PERMIT
DocCategory
Permit Applications (PA)
Notes
Owners
Parcel Address
BOTH SIDE OF LONE TREE RD. 0.25 MILES E/O CAMPBELL
Primary Parcel
Type (2)
PS-1302902
Tags
Permits_Development
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
The sampling procedure requires one end of the tubing to be been inserted into the ground a bentonite seal must be <br /> slipped over the sampling port and the other end over the formed between ambient air and the sample air. The <br /> canister nozzle or flow meter(if required)to acquire an air- bentonite must be hydrated and create an alrtightseal <br /> tight connection.The valve should be opened at this time around the probe.If required IPA can be placed on the joints <br /> and the initial pressure should then be recorded to verify that of the vapor probe and analyzed for in the sample to ensure <br /> the Summa canister is under vacuum. The Summa canister that ambient air is not diluting the soil vapor survey samples. <br /> is allowed to collect the soil vapor sample at a <br /> predetermined duration. After the sample has been pnce the sample apparatus has been set up new tubing will <br /> collected record the final vacuum reading(approximately five be connected to the inlet of the SKC sample pump. The <br /> pounds per square inch(psig))to ensure that the flow m eter pump operates at a low flow purge rate of 200 milliliters per <br /> was working properly,if applicable. Immediately following minute to prevent air stripping of contaminants from the soil. <br /> the sample collection,complete sampling information is Once three volumes have been evacuated(minimum 4.2 <br /> recorded on the label on the air sampling canister(e.g., minutes of sample time)a sample can be collected. <br /> sample iD,date,time,location,and temperature). The Verificatlon with a PID will determine when the maximum <br /> sample is placed in a non-refrigerated,dry cooler with concentration is obtained and a sample should be collected. <br /> sufficient packing to ensure against damage during If measurable concentrations are not obtained with the PID <br /> transport Cooling samples will cause condensation of any after 7 purge volumes(10 minutes)a sample should be <br /> moisture within the air sample,thereby distorting laboratory collected. Once a sample has been determined to be <br /> analysis. collected new tubing will be placed on the effluent of the <br /> sample pump running to the Tedlar bag,which should be <br /> Summa canister samples are subject to hold times of filled to 314 of volume capacity. Caution should be taken not <br /> typically 30 days and with some compounds a more rigid to overfill the sampling bag. The sample is placed in a non- <br /> hold time of 14 days is required. refrigerated dry cooler with sufficlent packing to eliminate <br /> damage during transport. Cooling samples will cause <br /> SOP-13 condensation of moisture within the sample,thereby <br /> SOIL VAPOR SAMPLING:SYRINGE SAMPLING distorting laboratory analysis. <br /> TECHNIQUE <br /> To minimize the potential for cross-contamination between <br /> Prior to vapor siunpling,the vacuum system must reach a air samples new polyethylene tubing will be used for every <br /> stabilized air flow(cubic feet per minute)for approximately sample. <br /> 15 minutes. Prior to the actual collection of the vapor <br /> sample,the following data Is recorded:air flow,temperature, Vapor samples are also subject to the same hold times and <br /> and pressure at collection ports and gauges. must be stored as stated in SOP-10. <br /> The sampling equipment consists of a clean,100cc,gas- SOP-15 <br /> tight syringe and silicone septa. SOIL GAS SAMPLING FROM DIRECT PUSH SOIL <br /> The sampling ports are brass connections,fitted with siliconeBORING:"TEDLAR"BAG SAMPLING TECHNIQUE <br /> septa,and threaded into a tapped hole In the system piping. To obtain soil gas samples from a direct push drill rig, <br /> Samples are col lected by inserting a clean syringe into the advance a discreet sampling rod with a 6-inch retractable <br /> septum and the plunger actuated several times. Each vapor screen to the desired sample depth. Release the <br /> syringe should be purged of three syringe volumes before sample screen cover from the screen and retract the rod 6- <br /> collecting the sample. On the fourth purge,the plunger is Inches. Place a dry bentonite powder layer In the annulus to <br /> extracted slowly until the syringe is filled with a gas sample, seal the borehole from surface air interference. Tamp the <br /> then the syringe is withdrawn and the needle immediately bentonite powder,place a hydrated bentonite layer In the <br /> plugged with a silicone stopper. The sample should be annulus,and follow with a second dry bentonite layer.Attach <br /> placed in a non-refrigerated,dry cooler with sufficient the soil gas sampling diaphragm pump to the rod casing <br /> packing to eliminate breakage during transport Cooling using polyethylene tubing. <br /> samples will cause condensation of moisture,thereby <br /> distorting laboratory analysis. The sampling equipment consists of a TedlarTm bag <br /> (available in 1,3,5,and 10 liter sizes),a diaphragm pump, <br /> Duplicate air samples should be collected as in SOP-10. and 3116-Inch-diameter polyethylene tubing(approximately 1 <br /> Vapor samples are also subject to the same hold times and foot long). The TedlarTm bag should be fitted with an Integral <br /> must be stored as stated in SOP-110. valve for filling and sealing the-bag after sampling.The <br /> diaphragm pump inlet and outlet are fitted with 3116•Inch <br /> SOP-14 hose barbs for attaching the sample tubing. A sample label <br /> SOIL VAPOR SURVEY SAMPLING:"TEDLAR"BAG with the sample number and date and time of sample <br /> SAMPLING TECHNIQUE collection is prepared and placed on the TedlarTm bag. <br /> The sampling equipment consists of a"Tedlar"bag The sampling procedure requires one end of the tubing be <br /> (available in 1,3,S.and 10 liter sizes),an SKC universal slipped over the direct push drill rod sample port hose barb <br /> sample pump,soil vapor probe,and 1/44nch-diameter and the other end over the diaphragm pump inlet hose barb <br /> polyethylene tubing(appro)imatefy three feet long), to form an air-tight connection. The sampling pump is then <br /> started and the pump is purged for 1 minute with the vapor <br /> A Roto-hammer or slam bar is used to obtain a three foot to be sampled. Following purging,the discharge of the <br /> hole into the ground area,where the soil vapor sample will pump is then connected to the TedlarTm bag using a section <br /> be collected. Once the hole has been formed the sail vapor of 3/164nch tubing. The pump is restarted and the bag is <br /> probe will be inserted into the hole and advanced the opened and allowed to fill to approximately 314 of its <br /> remaining two feet,five feet total below ground surface capacity. Caution should be taken not to overfill the <br /> (bgs),with the use of either a slide hammer,using a tee sampling bag. The sample is placed in a non-refrigerated <br /> adapter and using physical force. Once the vapor probe has dry cooler with sufficient packing to prevent damage during <br />