PW-ENCUTIL-2602052
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2026
>
PW-ENCUTIL-2602001 thru PW-ENCUTIL-2602500
>
PW-ENCUTIL-2602052
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2026 4:33:25 PM
Creation date
8/26/2026 2:41:27 PM
Metadata
Fields
Template:
Permits_Development
DocName
PW-ENCUTIL-2602052
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2026
Location
thornton rd
Type - Permit Process
install underground (UG) conduit via open-cut trenching across approximately 669 linear feet (ft.). Overhead (OH) work includes the installation of approximately 3,300 ft of OH conductor and the removal of approximately 2,299 ft of OH conductor. The work also includes the removal of 6 existing
poles, the installation of 13 new poles, the removal and installation of anchors, and overhead pole work.
Address
3136 Boeing Stockton, CA 95206
Application
Pacific Gas & Electric
Project #
730052
Type
Utility Encroachment
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
UTILITY ENCROACHMENT PERMIT <br /> <br />To: Pacific Gas & Electric <br />3136 Boeing <br />Stockton, CA 95206 <br /> <br />Permit No: PW-ENCUTIL-2602052 <br />Date Issued: 05/28/2026 <br />Start Date: 08/19/2026 <br />Exp. Date: 08/19/2027 <br />Project No. 730052 <br />Extended To: <br />UE/CR/PM NO: 35569642 <br /> <br />Encroachment Type: install underground (UG) conduit <br />via open-cut trenching across approximately 669 <br />linear feet (ft.). Overhead (OH) work includes the <br />installation of approximately 3,300 ft of OH conductor <br />and the removal of approximately 2,299 ft of OH <br />conductor. The work also includes the removal of 6 <br />existing poles, the installation of 13 new poles, the <br />removal and installation of anchors, and overhead <br />pole work. <br />Location: thornton rd <br /> <br />In compliance with your request of 05/28/2026, permission is herebygranted to do work in County right-of-way as <br />shown on attached application and subject to all the terms, conditions and restrictions written below or printed as <br />general or special provisions on any part of this form. See reverse side and attached sheet, if any. <br /> <br />Trench excavations for service connections will not be permitted within ten feet (10') of pavement centerline <br />unless otherwise approved by the Director. Surface of trench patches shall match in kind and be smooth and <br />even with that of abutting surface. Special attention shall be given to depth of utilities through roadside area in <br />anticipation of future draining facilities, road profile and/or frontage development. All underground utility facilities <br />are to be established and accurately dimensioned on sketches from surveyed centerline of road right-of-way, or <br />from right-of-way lines. <br /> <br />Permittee shall call the Department of Public Works, Field Engineering Division (Permit Inspection) at (209) 953- <br />7421 at least two business days prior to beginning any work within the County right of way. All work performed <br />under this permit shall conform to the rules and regulations pertaining to safety established by the California <br />Division of Occupational Safety and Health (Cal-OSHA.) <br /> <br />The jobsite shall be kept in a safe condition at all times by the daily removal of any excess dirt or debris which <br />might be a hazard to either pedestrian or automobile traffic. All necessary traffic convenience and warning devices <br />and personnel shall be provided, placed and maintained by and at the sole expense of the Permittee in <br />accordance with the latest edition of the CALTRANS Manual of Uniform Traffic Control Devices. <br /> <br />NON-ROAD CLOSURE PERMIT: Permittee/contractor MUST email County Field Engineering at <br />PWinspection@sjgov.org a minimum of (2) business days prior to the start of any work within County <br />right-of-way with the permit number, and contractor's contact information. <br /> <br />Special Comments:Traffic Control per MUTCD*No Bollards*No Road <br />Closures <br />Forms: SS/WW General Provisions R29 Trench Cut Policy <br />Permit Fee: <br /> <br />Najee Zarif, Director <br />Department of Public Works <br />By: Tim Callahan <br />Permit Section <br />