My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2009_EP-09-1201 thru EP-09-1400_ - PS-09-1265
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2009
>
EP-09-1201 thru EP-09-1400
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2009_EP-09-1201 thru EP-09-1400_ - PS-09-1265
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 3:41:38 PM
Creation date
1/11/2016 3:24:20 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-09-1265
Category07
Encroachment(EP)/Driveway(DW) Permits
SubCategory07
2009\EP-09-1201 thru EP-09-1400
Year2
2009
Supplemental fields
Card Printed
False
Copy To
CrossRef
DocCategory
PublicWorks
DocNum
FileName
PG&E
OrigTo
Project
4 BELL HOLE
Remarks
Reported
False
RptSupress
False
Summary
Title
VARIOUS LOCATIONS- MCBRIDE AVE AND ORANGE AVE
Tags
Permits_Development
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
?ar s and rlec'rc COmpcny <br /> er _n ?eccrc Special Facilities❑ (CP 107.er)❑ Existing(107.er)❑ <br /> F,_ GAS SERVICE RECORD <br /> r Agreemenl: <br /> N-r,i Nc 1037 3576 PM Order No.3066 0115 Leak No. Est. Name LCARDOZA Verbal ❑ <br /> Izcp Pit Na 3'21--E2—Block 1 Address:28839 ORANGE AVE, ESCALON Est. Phone No.347-5264 Written❑ <br /> Applicant/Tract <br /> NO, Y07—COPPER REPLACEMENT PROJECT Lot No. Date Issued: 3 17 09 By TMCE <br /> PROPOSE/EXISTING FACILITY Approx. Depth of Main Approx.Depth of Ex. Svc. Depth of Inst. Svc, Main Trench Occupied With: <br /> Inserted Trenched By ■ None <br /> Orr. Me'n ■ 2" HP PE ❑ Stl. ■ n Yes ❑ PVC❑ PE❑ Sll.❑ 1:1 Electric <br /> Se'v,ce❑ Size k Pressure CI ❑ Cu ❑ Casing: No C— Size ■PG&E phone <br /> ■ 9 Cl ❑ CU ❑ ❑ Tele <br /> ❑Applicant ❑ CAN <br /> On SOUTH_Side ORANGE AVE In Out 8' _ EJ Contractor <br /> EJ Other <br /> --- — <br /> PROPOSEU /EXISTING SERVICE LOCATION: JOB ORDER <br /> Service: Or NORTH Side ORANGE AVE, 2687' E/S ESCALON–RIVERBANK HWY Insert: <br /> Yes❑ No■ Casio Sae EJ NEW SERVICE <br /> E 5 ❑ STUB SERVICE " <br /> i S 7,_14— SlL❑ PE24060 PE34080 Aldyt–AD cu El PEs❑ PVC❑ Stl.❑ CU L1STUB COMPLETION <br /> L <br /> El BRANCH SERVICE <br /> R'sec Size3 4" x 1/2" Inside❑ Outside ■ Curb Valve: SVC Trench Occupied With REF. NO. <br /> Pre–Fob Non–Corrodible: Regular■ Short ❑ Long ❑ Metal❑PI. ❑None■ ❑ CURB METER <br /> Steel Encased–Plastic Insert ❑ Steel Riser ❑ Riser Valve: None■ Elec.❑ Phone ❑ ❑ MANIFOLD <br /> AY McDonald❑Mueller❑ CAN❑ Other ❑ CONVERT TO MAIN <br /> ■ REPLACEMENT <br /> No. of Outlets 1 _ Res. Meter(s) No, 1 Size DOMESTIC Reg. Size /Type: 3/4" _Orifice: 3/16" ❑ PARTIAL <br /> Comm. Meter(s) NQ._ Size Monitor Size/Type: Orifice: IN COMPLETE <br /> ❑ TRANSFER <br /> C/O Data 131' Ft 1Z2" CU In. Yr. Install 1948 Type: Stl.❑ PI.❑ CU ■ Reason: Leakage ❑ Other■ ❑ ALTER /INSPECTION <br /> Transfer From Main On Side In Out ❑ DEMOLITION <br /> Instructions and Cautions: REPLACE COPPER SERVICE WITH 1/2" PLASTIC, VENTING REQUIRED No. <br /> TRENCHED BY: PG&E APPLICANT INSTALLED BY: PG&E APPLICANT [-I CUT–OFF(C/0) <br /> BACKBONE ❑ ❑ BACKBONE 1:1 11 WORK <br /> AT MAIN El AT P/L <br /> WORK DONE: (Show corrections) _ ❑ OTHER <br /> COMPLETION ■ ❑ SVC COMP ■ ❑ to service and main data above) <br /> Ft. Main to End of Stub Electric UG in area YES❑ NO❑ <br /> DAZE STUB INSTALLED / / FOREMAN Ft. End of Stub to Riser TP HP SHP LP <br /> MANUFACTURER DD/MM/YY MANUFACTURED / / Total ft. MAOP PSIG/W.C. <br /> "" DATE COMPLETED FOREMAN Class Location: 1❑20 30 4❑ <br /> MANUFACTURER DD/MM/YY MANUFACTURED / /___ EFV Brand Type <br /> TEST DATA: (See Gas Standard A-34) Provide information for Posted By. ■Perfection F)Socket Fusion <br /> services off distribution systems (up to 60 PSIG MAOP) : WELDING INSPECTION ❑Other ■Permosert Ends <br /> PER PG&E GAS STD D-40 Specify <br /> STUB PSIG for Minutes <br /> COMPLETION PSIG for Minutes Date Flow Series – CTS(Inches) <br /> For services operating with an MAOP of above 60 PSIG, a'' iese c o ■400– 1/2" [11800 – 1" ❑1800 – 1" <br /> attach o copy of the Strength Test Pressure Report. El 800 – 1/2" El Other <br /> Speci/y <br /> FOLD <br /> CATHODIC PROTECTION: CPA No. GALVANIC CP SYSTEMS: LOCA111AG WARE CONNECTIONS: S'/C Wire Size <br /> ❑ <br /> Main under protection YES■ NO RISER E] RISER Reading_Date TERM. AT MAIN TERM. AT: RISER■ SVC El❑ — <br /> ❑ VALVE IN Bonded EJ Bonded <br /> Install cathodic protection(Per GS&S 0-16) El VALVE Reading—Dole <br /> ❑ SVC. <br /> ExistingEl New:❑ No. Installed El OTHER —Date OTHER Reading ❑Wrapped around Tee ■Stropped to Riser <br /> MAIN, ❑ <br /> ❑Nico–pressed wire at main EJ Terminated at curb valve <br /> Size _ Lb. Anode Type: MACE ZINC❑ Performed By. ❑N/A ❑N/A <br /> Sketch/Notes <br /> VENTING REQUIREDII <br /> I I <br /> I <br /> 28839 <br /> LLJU <br /> NI' <br /> �– 2H i <br /> W2"W HP STL-8' <br /> T. T. <br /> ORANGE AVE . <br /> NOTES: <br /> 1 . UTILIZE EXISTING METER LOCATION. f <br /> Q� 2. REPLACE EXISTING 1/2"CU WITH 1/2"PL. <br /> 3. INSTALL EFV AS SHOWN. <br /> 4. VENT REG AS REQUIRED PER STANDARDS. <br />
The URL can be used to link to this page
Your browser does not support the video tag.