Laserfiche WebLink
Pac�rc ':as and Elect^c 7cmoaev <br /> Gas Servire Record Special Facilities r- (!'F' 10%er)❑ Existing(107.er)❑ <br /> Form =54x8-1 GAS SERVICE RECORD — <br /> Agreement: <br /> Noti`.No. 1037 3576 PM Order No.3066 0115 Leak No. Est. None LCARDOZA Verbal ❑ <br /> flag Flit rlo-3121-E2 Block 1 Address:26766 ORANGE AVE, ESCALON Fst. Phone No.347-5264 Written❑ <br /> rppicc,tjTraci Name_ Y07-COPPER REPLACEMENT PROJECT Lot No. - 3ale'ssued: LI 09 By. TMCE <br /> IRCPOSED /EXISTING FACILITY: Approx. Depth of Main Approx, Depth of Ex. Svc. Depth of Inst. Svc. Main Trench Occupied With: <br /> Inserted Trenched By None <br /> 0!F Main 2" HP PE ❑ Stl. in Yes ❑ PVC❑ PE❑ Sll.❑ ❑ Electric <br /> Slee&Pressure Casin Six' PG&E <br /> Service[ CI ❑ CU ❑ Casing: No 9 CI ❑ CU ❑ ❑ Telephone <br /> L--- ❑Applicant ❑ CAN <br /> nn SOUTH Side ORANGE AVE In Out 8' _ ❑Contractor ❑ Other <br /> IRO'OSED /EXISTING SERVICE LOCATION. - JOB ORDER <br /> service On SOUTH Side ORANGE AVE, 2405' E/S ESCALON-RIVERBANK HWY Insert: <br /> Yes❑ No 0 Cash sae ❑ NEW SERVICE <br /> 9 ❑ STUB SERVICE " <br /> Sze_.1 2 Stl.❑ PE2406 PE3408❑ Aldyi-A❑ CU❑ pEs❑ PVC❑ Sil.❑ CU❑ ❑ STUB COMPLETION <br /> ❑ BRANCH SERVICE <br /> Riser: Size3 4° x 1 r Inside❑ Outside 0 Curb Valve: REF. NO. <br /> SVC Trench Occupied With: <br /> Pre-Fab Non-Corrodible: Regular N Short EJ Long EJ Metal❑PI. ❑None EI [I CURB METER <br /> Steel Encased-Plastic Insert ❑ Steel Riser El Riser Valve: None 0 Elec.❑ Phone ❑ ; F-1 MANIFOLD <br /> AY McDonald❑Mueller❑I CAN❑ Other ❑ CONVERT TO MAIN <br /> ■ REPLACEMENT <br /> He. of Outlets _ 1 Res. Meter(s) No. 1 Size DOMESTIC Reg. Size/Type: 3/4" _Orifice: 3/16" ❑ PARTIAL <br /> Comm. Meter(s) Na ■ COMPLETE <br /> Size Monitor Size/T}pe: _Orifice: <br /> C/C Data 74' Ft, 1Z2" CU In. Yr. Install 1946 ❑ TRANSFER <br /> Type: Stl.❑ PI.❑ CU � Reason: Leakage ❑ Other� EJ ALTER /INSPECTION <br /> -ransfer From Main On Side In _Out ElDEMOLITION <br /> Instructions and Cautions: REPLACE COPPER SERVICE WITH 1/2" PLASTIC, VENTING REQUIRED No. <br /> WRENCHED BY PG&E APPLICANT INSTALLED BY: PG&E APPLICANT ❑ CUT-OFF(C/O) <br /> ❑ AT MAIN ❑ AT PA <br /> BACKBONE ❑ ❑ BACKBONE ❑ ❑ WORK DONE: (Show corrections) ❑ OTHER <br /> COMPLETION O ❑ SVC COMP ❑ to service and main data above) <br /> Ft. Main to End of Stub Electric UG in area: YES❑ NO EJ <br /> DATE STUB INSTALLED / /-__ FOREMAN Ft. End of Stub to Riser TP HP SHP LP <br /> MANUFACTURER DD/MM/YY MANUFACTURED / / _ Total ft. MAOP PSIG/W.C. <br /> " DATE COMPLETED _/_/ FOREMAN Class Location: I❑20 3❑4❑ <br /> MANUFACTURER DD/MM/YY MANUFACTURED---/ /___ EFV Brand Type <br /> TEST DATA: (See Gas Standard A-34)Provide information for Posted By. �Perfecfion ❑Socket Fusion <br /> services off distribution systems(up to 60 PSIG MAOP) : WELDING INSPECTION [-1 Other OPermosert Ends <br /> STUB PSIG for Minutes <br /> PER PG&E GAS STD D-40 SP-6, <br /> COMPLETION PSIG for MinutesDote Flow Series - CTS(Inches) <br /> '.: <br /> For services operating with an MAOP of above 60 PSIG, iesrcroR — X400 - 1/2" ❑800- 1" F1 1800 - 1' <br /> attcch a copy of the Strength Test Pressure Report. 0800 - 1/2" ❑Other <br /> — __ SPecily <br /> FOLD <br /> CATHODIC PROTECTION: CPA No. GALVANIC CP SYSTEMS: LOCATING WERE CONNECTONS: SVC Wire Size <br /> Main under protection YES N NO ❑ ❑ RISER TERM. AT MAIN TERM AT: RISER 0 SVC❑ <br /> P ❑ RISER Reading_Date <br /> ❑ VALVE 0 Bonded ❑Bonded <br /> Install cathodic protection (Per GS&S 0-16) ❑ VALVE Reading—Date <br /> Existing: ❑ SVC. ❑ OTHER Reading ❑Wrapped around Tee Strapped❑ New:❑ No. Installed ❑ MAIN —Date PP pp d to Riser <br /> El 8 Nico-pressed wire of main E)Terminated at curb valve <br /> Size: Lb. Anode Type: MAGE] ZINC❑ Performedy ❑N/A ❑N/A <br /> Sketch Notes <br /> NOTES: <br /> 1 . UTILIZE EXISTING METER LOCATION. j <br /> 2. REPLACE EXISTING 1/2"CU WITH 1/2"PL. <br /> 3. INSTALL EFV AS SHOWN. <br /> 4. VENT REG AS REQUIRED PER STANDARDS. <br /> i <br /> `Q <br /> W2"W HP STL-8' <br /> (� T T. <br /> ORANGE AVE <br /> 2405• — ;---------- --- <br /> m VENTING REQUIRED <br /> I <br /> U I <br /> I <br /> 28766 <br /> a <br /> � I <br /> I <br />