Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
500' TO 1 <br /> PROPOSED PHASE DIAGRAM LIMIT LINE O .Y 1dN91S ,2 <br /> (F. BEACON) (T) Rip <br /> 06P T <br /> Il <br /> 0 <br /> 01 <br /> 716U <br /> 06P <br /> �� 08 1 1/2"C, 3#10 \ .u � i , • *\� '� <br /> 05 01 OR 06� (T) <br /> 02 07Pi i i08P 285LIM' TO 1 1 /2" C, Z G-30-01 3-31-0 <br /> 05 1 fy 07 T ❑4 ❑8 II-_ SCALE: 1"=20' <br /> 02 02P I1 N 20 10 0 20 40 <br /> (T) <br /> 02P Q <br /> 1"=20' GRAPHIC SCALE <br /> 1 1/2"C, 3#10, 1DLC <br /> STEADY DEMAND SEQUENCE (PROPOSED) POLE AND EQUIPMENT SCHEDULE <br /> FLASHING OPERATION: ALL RED ' LUMINAIRE SIGNAL <br /> STANDARD VEHICLE SIGNAL MOUNTING PED PPB G7 SIGN <br /> Red O 12" I <br /> NO. M A. M A: HPSV 9IACAP DGRADE LETTERS REMARKS <br /> TYPE MAST ARM POLE MIG. 0 ARROW <br /> 1-A TV-1-T SP-1-T 6 —► <br /> Yellow O 12" B 17-3-80 20' 15 200 W. MAS-4B SV-1-T SP-1-T 6 STATE ROUTE 120 R-34 <br /> C 1-A TV-3-T SP-1-T 8 <br /> ----- <br /> -C, <br /> "C, 3#10, 1DLC 2pp W, SV-1-T SP-1-T g s <br /> AUSTIN RD718U1 1/2 6 <br /> J Green 12" E 1-A TV-1-T SP-1-T 2 —► <br /> / O F 17-3-80 20' 15' 200 W MAS-4B SV-3-T SP-2-T STATE ROUTE 120 R-34 <br /> 1 i/2" CoGreen ® » �- AUSTIN ROAD 6 <br /> Arrow 12 1a� H 19-4-80 25' 15' 200 W. MAS, MAS SV-1-T SP-1-T 7 <br /> 171 1 EXISTING ADVANCE FLASHING BEACON ASSEMBLY. REPLACE SR4 SIGN ASSEMBLIES WITH A W41 SIGN. <br /> 'J; ADVANCE FLASHING BEACON ASSEMBLY. REPLACE R1 SIGN WITH A W41 SIGN. SEE NOTE 10 <br /> 2"C, 3#10, 3DLC (T) ❑ 'K) ADVANCE FLASHING BEACON ASSEMBLY. REPLACE R1 SIGN WITH A W41 SIGN. SEE NOTE 10 <br /> DETAIL "A„ Al 'L' EXISTING ADVANCE FLASHING BEACON ASSEMBLY. REPLACE SR4 SIGN ASSEMBLIES WITH A W41 SIGN. <br /> N.T.S. 3 I 04P 1000' TO <br /> 1 1/2"C, 2#10 6 06PPB 06PPB - ALL VEHICULAR HEADS SHALL BE 120 <br /> . <br /> LIMIT LINE <br /> 1 1/2"C-MT O 718L - ALL RED INDICATIONS (SOLID AND ARROW) AND RAISED HAND SHALL BE LED TYPE. 350' TO LIMIT LINE (�CON) <br /> 2"C-MT, TO PHONE CO. Q O EX. 2"C 5#10 2#8 <br /> 2"C, 3 6 <br /> 2#6, 2#10Q 2 Q 08PP6 2"C, 4DLC ADD 2#6, 2#10 EX. 2"C, 3#2 EX. 1 1/2"C 4#10 EX. 1 1/2"C, 4#10 <br /> STATE ROUTE 120 EX. „/2"�' 3#'° <br /> 1 1/2"C, 3#10 04P,6 R 06838 O EX. "C, 5#10, 2#8 2"C 2#6 2#10 <br /> ❑ PG&E ' <br /> EX. 1 1/2- CN 4#10 MMMMy NNMMN w�M� 1 1/2"C, 1 DLC MSH ` r 11 08 ____� 6(T) N _M ____ 2Ca 1 1/2"CN 1 DLC N M ' TX VAULT N N 1 1/2-C. 1DLC I ; <br /> 1 1/2" C. ❑4 ❑8 6(T), _ Og _ 08 7 - - _ -- - �,►`„-- - _ n - (T) - Lu <br /> 0 - 05 - _ - _ _ •�_� _ - . <br /> �� - - (O EX. 1 1/2-C, 5 10, 2#8 _S `ei v�ar� Pist ly <br /> EX. 1 1/2"C, 4#10 ❑2 1 1/2 C, 4 <br /> EX. 2 C, 5#10, 2#8 WB-1 0683A ' 06 08 6J4U 1 1/2"C, 2DLC 8 6J2U <br /> 14 <br /> 501 13 --.350' TO LIMIT LINE :�� 5J1U 01 05 ® tlts 13 <br /> TO LIMIT LINE <br /> 9.d2 212U 1 1/2" C. 214U gQ 07 ❑7 02 06 5 EB-1 <br /> ,F_� L , ( ) 1 1/2"C,' 1DLC ( ) » 2" C, 4 8 2130 1 1 2"C 4 8 <br /> Y �r T r T 1 1/2-C, 1DLC — ;-",,� _ ❑ _ cT) _ 6 , �7 �1 �' �2 6cT _ / ❑ ❑ STATE ROUTE 120 <br /> EX. 1 1/2"C, 4#10 -------____��� ________ - �______� - - 2 5 1 1/2"C, 1DLC ------ <br /> AWG CONDUCTOR SCHEDULE 2"C, 5DLC 4 os83c PROJECT NOTES <br /> D 02P <br /> OR POLE OR RUN No. 8 (T 08PPB 1 1/2-C, 3#10 <br /> CABLE CIRCUIT 1 2 3 4 5 6 7 8 9 ❑ F 6 8J8L jl, O02PP8 / # ❑1 STATE SYSTEM No. 0OW HPS LUMINAIRES E 08P EX. 1 1/2"C, 3#10 LOAD 4-200W HPS LUMINAIRES <br /> EX. 2"C, 4#10 r<' 1-3,800W TRAFFIC SIGNAL SYSTEM <br /> POLE A 1-1-0 1-1-0 04P R 2 C, 3#10, 3DLC <br /> 02PP6 <br /> 3-9-12 POLE C 1-1-1 1-1-1 07PP6 T ❑2 EXISTING TYPE III-CF SERVICE, (120/24OV). <br /> POLE B 1-1-0 1-1-0 1-1-0 02P ❑5 10 0 PROVIDE ITEMS NEEDED TO COMPLETE TRAFFIC SIGNAL METERING. <br /> 1-1-1 1-1-1 <br /> CONDUCTOR POLED 1-0-1 1-0-1 1-0-1 1-0-1 1-0-1 1-0-1 1—f-"`-- - _1 oN Q <br /> CHANGE ITEM 16 TO READ "INTERSECTION LIGHTING". <br /> POLE E 1-1-0 1-1-0 1-1-0 1-1-0 1-1-0 j 0 ❑3 INSTALL STATE FURNISHED MODEL 170-CONTROLLER ASSEMBLY AND MODEL 332 CABINET. <br /> CABLE POLE F 1-1-1 1-1-1 1-1-1 1-1-1 fl C��Jlrt4 i' � AC, ���<E; Ef 1 1/2" Cl CONTRACTOR SHALL FURNISH AND INSTALL FOUNDATION BOLTS AND FOUNDATION-ES-3C. <br /> C. <br /> 6rv1,5s w�(f<, E ❑4 LOOP CONDUCTOR PAIRS SHALL BE TWISTED (SEE ES-5A) <br /> POLE H 1-0-1 1-0-1 1-0-1 , ❑8 Z ❑5 INSTALL ALONG THE LENGTH OF THE RADIUS AN ASPHALT <br /> TOTAL CABLES 7-5-47-5-4 2-2-1 1-1-1 1-0-1 2-1-1 3-2-2 3-2-2 1-0-1 II-_ CONCRETE DIKE, TYPE A. INSTALL BREAKS FOR PEDESTRIANS. <br /> 10 F. BEACON 3 3 3 <br /> 8J8U V) ❑6 R73-3 SIGN ON MAST ARM NEXT TO LEFT-TURN ARROW SECTION HEAD. <br /> 10 IISNS 2 2 2 2 2 2 2 1 SEE SM. PLANS SHEETS S-18A AND ES-33 FOR MOUNTING DETAILS. <br /> PHASE 7 AND 8 MASTARM SIGNAL HEADS SHALL BE <br /> 10 LUMINAIRE 2 2 2 2 2 2 2 Q F11PHASE <br /> HEADS, RED BALL, YELLOW BALL, GREEN BALL AND GREEN LEFT-TURN ARROW, SEE DETAIL A. <br /> 6 SERVICE <br /> 2 2 2 2 ❑8 SEE ES-5E FOR SHOULDER TERMINATION <br /> 1 <br /> 2 3 3 1 3 AI 1 1/2"C, 3#10, 1DLC ❑9 INSTALL TELEPHONE SERVICE. PHONE CONDUIT SHALL BE <br /> 7 3 INSULATED FROM SERVICE POINT TO SIGNAL CABINET. <br /> D.L.C. 5 2 2 2 1 CALL BEFORE YOU DIG 8 285' TO INSTALLATION SHALL CONFORM TO LOCAL PHONE COMPANY'S <br /> 6 2 2 2 2 CALL USA AT: I (T) LIMIT LINE REQUIREMENTS AND STANDARDS. <br /> 81 3 3 3 1 3 3 1 /2» C 10 RELOCATE EXISTING FLASHING BEACON TO LOCATION J. ABANDON FOUNDATION. REPLACE R1 SIGN WITH A W41 SIGN. <br /> EB 1 1 1 1 1 1 1 1 -800-227-2600 8J6U ❑4 INSTALL AMBER LENSE. <br /> WBI 1 1 1 11 RELOCATE EXISTING FLASHING BEACON TO LOCATION K. ABANDON FOUNDATION. REPLACE R1 SIGN WITH A W41 SIGN. <br /> TOTAL D.L.C. 17 14 4 4 1 4 4 9 1 I 1 1/2"C, 3#10 <br /> INSTALL AMBER LENSE. <br /> 12 REPLACE EX. "STOP AHEAD" PAVEMENT MARKING WORDS WITH "SIGNAL AHEAD (THERMOPLASTIC). <br /> KNEAD13 REPLACE EX. "SCHOOL" PAVEMENT MARKING WORD WITH "SIGNAL", (THERMOPLASTIC). <br /> CONDUIT SIZE 2-4" 2-4" 3" 3" 2" 3" 3" 3" 2" 12 (T 500' TO 14 REMOVE ALL PAVEMENT MARKERS AND TRAFFIC LINES WITHIN THE INTERSECTION AS NEEDED <br /> SINAI Y ` LIMIT LINE TO INSTALL YELLOW CROSSWALKS, (THERMOPLASTIC). <br /> UNDERGROUND SERVICE ALERT O (F. BEACON) THIS PLAN ACCURATE FOR ELECTRICAL WORK ONLY <br /> DRAWN BY DATE PROJECT ENGINEER DATE CHECKED DATE SUBMITTED DATE APPROVED DATE SHEET TOTAL <br /> GIP 7/2000 9 �� v � � 7/00 �,� t � 7/00 COUNTY OF SAN JOAQUIN SCALE AS NOTED TRAFFIC SIGNAL PLAN STATE ROUTE 120 AND AUSTIN ROAD 2 SN2 <br /> "/ .c.�=(',u, <br /> 2 2 <br /> j�aNAME DRAWER SHEET NO. ACAD REVISIONS DATE <br /> 01\ j c:\SR120JWSTINRD <br />