My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2016_PS-1600000 thru PS-1600500_ - PS-1600453
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2016
>
PS-1600000 thru PS-1600500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2016_PS-1600000 thru PS-1600500_ - PS-1600453
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2021 8:45:55 AM
Creation date
4/27/2016 2:14:45 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-1600453
Category07
Encroachment(EP)/Driveway(DW) Permits
SubCategory07
2016\PS-1600000 thru PS-1600500
Year2
2016
Address
E/S BELVEDERE AV 171'S/O E EUCLID AVE
Application
SEFNCO- CHRIS PERRY
Supplemental fields
APN
PS-1600453
Cross Ref
PWP7110005
Type (2)
Encroachment Permit (EP)
Zip
94550
Tags
Permits_Development
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
Show annotations
View images
View plain text
~lolVwllilt'5 below. <br />CalJb~fOlIJOlldi9- <br />-ll::<CI- <br />~UW Z...IW 00rnI-..I::l -e:t ~z0 ZIn-Ionll::ll::~e:t N:c (II) <br />,...•••N -In ~,...D::N WNa. <br />,i,I <br />! <br />I, <br />•!, <br />re.COMCAST <br />@.F~,~ <br />~~~ <br />NOTES &LEGEND <br />2 OF 5 <br />PROPOSED DIRECTIONAL DRILL <br />PROPOSED BORE <br />EXISTING PULL THRU <br />PROPOSED OPEN TRENCH <br />AERIAL STRANO <br />~"-"-"-"~'.'j'iiCii~-"-"-"-"- <br />-'-"~1U.~TiNGpu"~'l;;;U-"-"~ <br />-"-"-"i;';;';-OfiijUii-'NOj""-"-"- <br />LEGEND: <br />RIGHT..QF.WAY <br />TRAFFIC LANE <br />CENTERUNE <br />FENCE <br />GAURD RAIL <br />FIBER PLACEMENT NOTES: <br />1.CONTRACTOR IS RESPONSIBLE FOR LOCATING AU.UTIUTIES 48 HOURS PRIOR TO CONSTRUCTION ACTNITY <br />SEE LOCAl DIRECTORY FOR CONTACT TELEPHONE NUMBER OF LOCAl CALL BEFORE YOU DIG AGENCY. <br />2.CONTRACTOR SHALL RECORD SEQUENCE'OF FIBER CABLE AT EVERY INORK POLE,MANHOLE.FIBER STORAGE LOOP <br />AND TAIL LOCATION.CONTRACTOR TO PROVIDE PROJECT MANAGER WITH SEQUENCE NUMBERS AT PROJECT <br />COMPLETION. <br />3.SLACK LOOP AND SNOWSHOE STORAGE LOCATIONS SHAlL BE DETERMINED ON CONSTRUCTION DRAWINGS,HOW'EVER. <br />REEL LENGTHS OF FIVE HUNDRED FEET (500')OR LESS ON LARGE COUNT FIBER OR THREE HUNDRED FEET (300')OR LESS <br />ON SMALL COUNT FIBER ARE DIFFICULT TO USE AND SHOULD BE PLACED AS FSL'S.NOT CUT AND RETURNED. <br />4.FIBER OPTIC IDENTIFICATION TAGS SHALL BE PLACED AT EVERY WORK POLE,MANHOLE,FIBER.STORAGE LOOPS.SPLICE <br />CASES AND WHERE INDICATED BY PROJECT MANAGER.TAGS NEEO TO BE PLACED SO AS TO BE READ FROM THE GROUND. <br />5.CABLE LUBRICATION SHALL BE USED TO REDUCE PULLING TENSION.LUBRICANTS MUST NOT CONTAIN ANY PETROLEUM <br />PRODUCTS. <br />6.A 100 FOOT FIBER COIL MUST REMAIN IN AlL VAULTS UNLESS OTHERWISE NOTED. <br />7.ALL BURIED INFRASTRUCTURE MUST BE ACCOMPANIED WITH WARNING TAPE AND A TRACER WIRE,AT RISER POLES THE <br />LOCATE WIRE SHALL BE ACCESSIBLE AT THE BASE OF THE RISER. <br />ALL RISERS WILL BE CAPPED AT All TIMES. <br />9.ALL FIBER SHAlt.BE MARKED AS TO DIRECTION IN EACH VAULT.RED-NORTH.GREEN.SOUTH,YELLOW-EA5T.AND <br />BLUE.WEST.00 NOT TAPE FIBER CABLES TOGETHER IN RISER. <br />~PROPOSED BORE PIT C'Q EXISTING POLE WI NEW RISER @@@ MANHOLE <br />~STREETISIGNAUTRAFFIC LIGHT (.I"LANDSCAPINGrrREE _._---SEWER'/@ CONSTRUCTION NOTE <'"'.-TRAFFIC FLOW -----WATER <br />~FIRE HYDRANT 0 PROPOSED VAULT -----STORM DRAIN,-,POTHOLE LOCATION _._---POWERIIW@!]CATCH BASIN .- <br />~'"~BUILDING OUTLINE -----COMMUNICATIONS <br />CHANNELIZATtON?5+39 STATIONING GAS..;;------ <br />DISCLAIMER: <br />1.IT IS THE RESPONSIBILITY OF THE CONSTRUCTION CONTRACTOR TO VERIFY ALL RIGHl OF WAY <br />BEFORE CONSTRUCTION IS TO BEGIN_NO UNDERGROUND INSTALLATION REPRESENTED WITHIN <br />THESE PLAN SHEETS IS PROPOSED OUTSIDE OF THE RIGHl OF WAY. <br />2.THE UNDERGROUND ROUTE DEPICTED IS PRELIMINARY AND WlLI.JMAY VARY ONCE UTILITIES HAVE <br />BEEN FIELD LOCATED. <br />J.ANCHORING FOR THE AERlAl CONSTRUCTION IS TYPICALLY DETERMINED DURING CONSTRUCTION <br />AND IS COLLECTED IN THE AS-BUILT PHASe. <br />GENERAL NOTES: <br />1.ALL VAULTS I HANOHOLES TO BE EQUIPPEO WITH SECURITY LIDS WITH lOCKING BOLTS. <br />2.GROUND RESTQRATlDWRIGHT-OF-WA'l'SHAll.BE RESTORED TO ORIGINAL OR BETTER CONDITION <br />3.ALL 90 OEGREE BENDS IN CONDUIT CONSTRUCTION WILL BE A MINIMUM OF:36"RADIUS UNLESS <br />SPECIFIED OTHERWIse. <br />4.BURIEO fiBER OPTIC WARNING SIGNS SHALL BE PLACED AT EACH SIDE OF ALL ROAD CROSSINGS, <br />AT CULVERTS,DITCHES AND IN A STRAlGHT LINE OF SIGHT SPACING OF APPRO)(IMATEl Y 500 fEET. <br />5.DEVIATIONS FROM THE ENGINEERED ROUTE REQUIRES A PROJECT MANAGER AND RIGHT-OF.WA,( <br />OWNER OR CARETAKER APPROVAL PRIOR TO CONSTRUCTION. <br />6.VVHERE PERMITS FROM STATE.COUNTY,CITY,RAILROAD OR GOVERNMENT AGENCIES ARE <br />REQUIREO,ALL WORK PERFORMEO WILL COMPLY WITH THESE AGENCIES STANDARD <br />SPECIFICATIONS. <br />7.THE PROJECT MANAGER WILL NOTIFY BUILDING MANAGEMENT WHEN IIVORK WILL BEGIN ON <br />BUILDING.CONTRACTOR TO COORDINATE ROOM ACCESS AND WORK START AND STOP TIMES <br />WITH BUILDING MANAGEMENT. <br />B.THE PROJECT MANAGER IS TO BE NOTIFIED BY THE CONTRACTOR 24 HOURS PRIOR TO <br />CONSTRUCTION.SEE COMPANY CONTACT LIST FOR CONTACT NAME(s)AND TELEPHONE NUMBER(s). <br />9.THE PROJECT MANAGER WILL RESERVE THE RIGHT TO INSPECT AT ANY TIME THE IIVORK BEING <br />PERFORMED BY THE CONTRACTOR.IF PROJECT MAI'iAGER DETERMINES THATTHE IIVORK IS NOT <br />BEING PERFORMED TO MINIMUM QUAUTY STANDARDS,THEN THE CONTRACTOR SHALL PROVIDE <br />REWORK AT HIS OWN COST. <br />10.ANY CHANGE IN PROJECT SCOPE,INCLUDING BUT NOT LIMITED TO,CONDUIT LENGTH,CONDUIT <br />PATH,AERIAL PATH ETC.,MUST BE APPROVED BY THE PROJECT MANAGER. <br />11,AlL CORING/CONSTRUCTION THAT WILL CAUSE NOise AND/OR VlBRATION SHALl BE OONE WITHIN <br />ALLOWED (9AM-3PM)BUStNESS HOURS. <br />12.ANY AND ALL UNDERGROUND UTlUTIES ENCOUNTERED ARE THE RESPONSIBIUTY OF THE <br />CONTRACTOR TO LOCATE,PROTECT,AND REPAIR,IF DAMAGED. <br />13,AlL FOOTAGES ARE BASED ON FIELD GATHERED MEASUREMENTS.AS SUCH SOME VARIANCE <br />SHOULD BE ANTICIPATED.ADJUST AS NEEDED <br />14.ALL BURIED CONDUITICABLE WILL BE PLACED AT 36"MINIMUM COVER.SITE HAS POTENTIAL FOR <br />ROCK THAT WOULD PREVENT THE ABILITY TO PROVIDE THE MINIMUM COVER.tN CASES WHERE THE <br />MINIMUM COVER CAN NOT BE ACHIEVED.THE CONDUIT SHALL BE PLACED IN A SCH 40 EMT SLEEVE <br />OR APPROVED EOUIVALENT, <br />15.WATER,SEWER,STORM SEWER ANO EASEMENT LOCATIONS ARE BASEO OFF OF CITY MAPS, <br />NOT FIELD VERIFIED. <br />16.BORING OF AC PAVING IS REQUIRED AT ALL LOCATIONS AS INDICATED ON PLANS. <br />17.AT NO TIME SHALL CURBS.GUTI£RS OR HANDICAP BE DISTURBED. <br />lB.DOOR HANGERS ARE TO BE PlACED A MINIMUM OF 72 HOURS PRIOR TO START OF CONSTRUCTION. <br />19.PRIOR TO START OF CONSTRUCTION.CONTRACTOR SHALL PLACE MESSAGE BOARDS STATING LANE <br />CLOSURES,AND DELAYS A WEEK IN ADVANCE.LOCATION OF THE MASSAGE BOARD SHALl BE <br />COORDINATED WITH THE CITY INSPECTOR AT THE PRE.CONSTRUCTION MEETING. <br />20.LANE CLOSURES CANNOT EXCEED MORE THAN 300 FT.AT A TIME.FOR SAFETY PURPOSES THERE <br />SHALL BE ONLY ONE CLOSURE AT A TIME ALONG INTERNATIONAL BLVD.MORE FLAGGERS WILL BE <br />NECESSARY TO HELP VEHICLES AND PEDESTRIANS IN THE INORK ZONES DURING THE LANE <br />CLOSURES.
The URL can be used to link to this page
Your browser does not support the video tag.