My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2800 - Aboveground Petroleum Storage Program
>
PR0516198
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:57:11 PM
Creation date
8/24/2018 6:23:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516198
PE
2832
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0516198\COMPLIANCE INFO 2000 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2000 - 2016
QuestysRecordDate
12/19/2017 10:45:19 PM
QuestysRecordID
3750331
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRC13,January 2002 Pae I of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: 11 Tank Manufacturer L7 Industry Standard F] Professional EngineerIiOther(Spec) <br /> Test Method Used: 13 Pressure C]Vacuum ❑Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Tank# c Tank# Tank# Tank# <br /> Is Tani*Exempt From'l'esting?l ©Yes No ❑Yes ❑No 11 Yes ❑No ,. -Yes LI No <br /> Tank Capacity: <br /> "yank Material: <br /> Tank Manufacturer: <br /> Product Stored: <br /> Wait time between applying , <br /> vacuum and starting test: <br /> Test Start Time: <br /> [nitial Reading(Ri): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Change in Reading(RF-Ri): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass D Fail <br /> Was sensor removed for testing? D Yes ❑No ❑NA D Yes D No D NA ❑Yes D No DNA D Yes D No ❑NA <br /> Was sensor properly replaced and D Yes D No D NA D Yes ❑No D NA ❑Yes ❑No 0 N ❑Yes ❑No D NA <br /> verified functional after testin ? <br /> Comments—(include_ in ormation on repairs made prior to testing, and recommendedfollow-up or ailed tests <br /> Not Tested with this Testing Event! <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. (California Code of Regulations,Title 23, Section 2637(a)(6)) <br />