My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2800 - Aboveground Petroleum Storage Program
>
PR0516198
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:57:11 PM
Creation date
8/24/2018 6:23:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516198
PE
2832
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0516198\COMPLIANCE INFO 2000 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2000 - 2016
QuestysRecordDate
12/19/2017 10:45:19 PM
QuestysRecordID
3750331
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 <br /> Page <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps X <br /> Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer ❑Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: a Pressure ❑Vacuum ❑Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used_ Equipment Resolution: - <br /> Fill Sump# Fill Sump # Fill Sump# Fill Sump# <br /> FHi <br /> mp.Diameter: <br /> m Ile the <br /> eight frim Tank Top to Top of <br /> hest Piping <br /> i in Penetration: <br /> Height from Tank Top to Lowest <br /> rEectrical Penetration: <br /> dition of sump prior to <br /> n <br /> ion of Sum Tested <br /> Material: <br /> Wait time between applying -- <br /> water and startin test: <br /> Test Start Time: <br /> Initial <br /> Readin (R,): <br /> Test End Time: <br /> Final Reading(RF <br /> Test Duration: <br /> Clan a in Reading(RF-Ru): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: ❑ Pass ❑Fail ❑ Pass Q Fail ❑ Pass ❑Fail 0 Pass ❑Fail <br /> Is there a sensor in the sump? ❑Yes ❑No [I Yes ❑No ❑ Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is []Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? Q Yes ❑No ❑NA Q Yes Q No [INA ❑Yes ❑No Q NA L)11 <br /> ❑No C]NA <br /> Was sensor properly replaced and <br /> verified functional after testing? Q Yes 0 No ❑NA ❑Yes ❑No ❑NA ❑Yes Q No ❑NA ❑Yes ❑No ❑NA <br /> _Comments — (include information on i*,pairs made prior to testing and recommended follow-upyfor failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.