My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2800 - Aboveground Petroleum Storage Program
>
PR0516198
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:57:11 PM
Creation date
8/24/2018 6:23:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516198
PE
2832
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0516198\COMPLIANCE INFO 2000 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2000 - 2016
QuestysRecordDate
12/19/2017 10:45:19 PM
QuestysRecordID
3750331
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> SWRCB,January 2002 Page 5 of <br /> 7. UNDER-DISPENSER CONTAINMENT (IJDU TESTING <br /> ffEquipment <br /> By: ❑UDC Manufacturer ❑ industry Standard ❑Professional Engineer <br /> Q Other(Spec) <br /> Q Pressure 'l Vacuum ❑Hydrostatic <br /> Q Other(.Spee) <br /> Equipment Resolution: <br /> _ UDC# UDC# UDC# UDC# <br /> UR Manufacturer: <br /> UDC Material: <br /> UDC Depth: <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: <br /> Height from.UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testin <br /> Portion of UDC Tested <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both 11 Yes ❑No ❑NA O Yes ❑No [INA Cl Yes ©No ❑NA fl Yes ❑No ❑NA <br /> product and water)?* <br /> Turbine shutdown res once time <br /> Is system programmed for fail- ❑Yes l7 No ❑NA ❑Yes O No ❑NA D Yes ❑No ❑NA ❑Yes ❑Na CI NA <br /> safe shutdown?* <br /> Was fail-safe verified to be <br /> ❑Yes ❑No DNA ❑Yes ❑No DNA Q Ye ❑No NA YNo [INAoperational?* <br /> Wait time between applying <br /> water and startin test <br /> Test Start Time: <br /> Initial Reading(111): <br /> Test land Time: <br /> Final Reading(Rr): <br /> Test Duration: <br /> Change in Reading(RF-Ra): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: ❑ Pass D Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑ Fall <br /> Was sensor removed for testing? ❑ Yes Q No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and [7 Yes ❑No ❑NA ❑Yes Q No n NA ❑Yes ❑No ❑NA U Yes ❑No ❑NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testingand recommended follow-up for failed tests) <br /> t3DC'S not Tested with this Testing event! "`— <br /> ` If the entire depth of the UDC is not tested,specify how much was tested, if the answer to My of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.