My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2800 - Aboveground Petroleum Storage Program
>
PR0516198
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:57:11 PM
Creation date
8/24/2018 6:23:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516198
PE
2832
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0516198\COMPLIANCE INFO 2000 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2000 - 2016
QuestysRecordDate
12/19/2017 10:45:19 PM
QuestysRecordID
3750331
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• � � !/��vp�Cf <br /> Page 6 of S <br /> $, FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps EI <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer ❑ Industry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ❑ Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Fill Sump # Fill Sump # Fill Sump # Fill Sump # <br /> Sump Diameter: <br /> Sump Depth: <br /> Height from Tank Top to Top of <br /> Hi hest Pi6nQ Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of sum rior to testing: <br /> Portlon of Sump Tested <br /> Sump Material: <br /> Wait time between applying <br /> pressurelvacuumlwater and starting <br /> test: <br /> Test Start Time: <br /> Initial Reading(R): <br /> Test End Time: <br /> Final Reading RF): <br /> Test Duration: <br /> Change in Reading(RF-Ri <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: ❑ Pass E3 Fail] ❑.Pass ❑.Fail E3 Pass ❑ Fail ❑ Pass E3 Fail <br /> Is there a sensor in the sump? ❑Yes L3 No ❑Yes ❑ No ❑Yes L3 No ❑Yes E3 No <br /> Does the sensor alarm when either ❑Yes ❑ No '❑ NA ❑ Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br /> roduct or water is detected? <br /> Was sensor removed for testing? ❑Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA ❑Yes ❑ No 0 NA ❑Yes ❑ No ❑ NA <br /> Was sensor properly replaced after L3 Yes E3 No © NA ❑Yes E3 No L3 NA El Yes E3 No C3 NA EI Yes E3 No E3 NA <br /> testing? <br /> Comments— include information on repairs made prior to testing, and recommended follow u for failed fesfs <br />
The URL can be used to link to this page