My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOOMIS
>
3112
>
2800 - Aboveground Petroleum Storage Program
>
PR0535482
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2019 3:46:58 PM
Creation date
8/24/2018 6:42:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0535482
PE
2832
FACILITY_ID
FA0003790
FACILITY_NAME
LDS - STOCKTON BISHOPS STOREHOUSE
STREET_NUMBER
3112
STREET_NAME
LOOMIS
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17910008
CURRENT_STATUS
01
SITE_LOCATION
3112 LOOMIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOOMIS\3112\PR0535482\COMPLIANCE INFO.pdf
QuestysFileName
COMPLIANCE INFO
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />February 02, 2016 <br />Facility Address: <br />3112 LOOMIS RD, STOCKTON <br />Facility Name: <br />LDS - STOCKTON BISHOPS STOREHOUSE <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone:(209) 468-3420 Fax :(209) 468-3433 Web:www .sjgov .org /ehd <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Remarks Item # <br />616 CFR 112.7(f)(3) Failed to schedule and conduct discharge prevention briefings at least annually. <br />Discharge prevention briefings are not scheduled at least once a year. The SPCC training log in the SPCC Plan did <br />not include training in 2015. The training dates listed are 2/19/13, 2/18/14, and 1/27/16. Discharge prevention <br />briefings for oil handling personnel must be scheduled and conducted at least once a year to assure adequate <br />understanding of the SPCC Plan for that facility. Such briefings must highlight and describe known discharges or <br />failures, malfunctioning components, and any recently developed precautionary measures. Ensure that they are <br />scheduled and conducted at least once a year. <br />This is a Class II violation. <br />713 CFR 112.8(c)(6) Failed to perform scheduled tank tests and inspections by appropriately qualified personnel. <br />No integrity test results were available for the 12,000 gallon diesel tank. Integrity testing was not discussed in the <br />Plan. Each aboveground container shall be tested and inspected for integrity on a regular schedule and whenever <br />repairs are made. The qualifications of personnel performing tests and inspections, frequency and type of testing and <br />inspections that take into account container size, configuration, and design shall be determined in accordance with <br />industry standards. Examples of these integrity tests include, but are not limited to: visual inspection, hydrostatic <br />testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive <br />testing. Comparison records and other records of inspections and tests must be maintained on site. Immediately <br />conduct the necessary testing and submit a copy of the test results to the EHD, or provide equivalence as allowed by <br />CFR 112.7(a)(2). <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by March 3, 2016. <br />Please be aware as of January 1, 2013, all businesses are required to submit all new (or any changes to existing) <br />Aboveground Petroleum Storage Act (APSA) information online to the California Environmental Reporting System <br />(CERS) at http://cers.calepa.ca.gov in addition to any other relevant activities and required fields. No later than <br />January 1, 2014, all APSA data must be entered and or updated in CERS. <br />Documents reviewed: SPCC Plan, Spill Reports, Monthly & Annual inspection forms, Inventory Reconciliation <br />Inspection forms, Training records <br />Documents provided: Return to Compliance Certification form, Schedule of free CUPA classes <br />Page 5 of 6