0 0 Page 2 of 2 <br /> As discussed the tanks are surrounded by a 4-foot high CMU (concrete masonry unit) wall (see attached <br /> photos). Is this wall considered to be a dike, and/or a containment structure, that is designed to hold the <br /> fluids of the largest tank within a confined area? It is for the licensed Professional Engineer to certify. <br /> Additionally, what are the design requirements for above-ground fuel tanks?According to CFR 112.8(c)2 <br /> Construct all bulk storage tank installations so that you provide a secondary means of containment for the <br /> entire capacity of the largest single container and sufficient freeboard to contain precipitation. You must ensure <br /> that diked areas are sufficiently impervious to contain discharged oil. Dikes, containment curbs, and pits are <br /> commonly employed for this purpose. You may also use an alternative system consisting of a drainage trench <br /> enclosure that must be arranged so that any discharge will terminate and be safely confined in a facility <br /> catchment basin or holding pond. <br /> Thank you for your assistance. <br /> Gerald "Chip" Jones <br /> Project Manager <br /> Housing Authority of the County of San Joaquin <br /> Phone:(209) 460-5042 Mobile: (209) 406-6206 <br /> CONFIDENTIALITY NOTICE:This communication with its contents may contain confidential,private and/or legally <br /> privileged information.It is solely for the use of the intended recipient(s). Unauthorized interception,review,use or <br /> disclosure is prohibited and may violate applicable laws including the Electronic Communications Privacy Act.If you are <br /> not the intended recipient,please contact the sender and destroy all copies of the communication.Further, if the reader of <br /> this message is not the intended recipient,you are hereby notified that any dissemination,distribution or copy of this <br /> communication is strictly prohibited.(Revised 10/5/10) <br /> CONFIDENTIALITY NOTICE: This communication with its contents may contain confidential, <br /> private and/or legally privileged information. It is solely for the use of the intended recipient(s). <br /> Unauthorized interception, review, use or disclosure is prohibited and may violate applicable laws <br /> including the Electronic Communications Privacy Act. If you are not the intended recipient, please <br /> contact the sender and destroy all copies of the communication. Further, if the reader of this message <br /> is not the intended recipient, you are hereby notified that any dissemination, distribution or copy of <br /> this communication is strictly prohibited. (Revised 10/5/10) <br /> 3/27/2013 <br />