My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2020 9:26:53 AM
Creation date
9/4/2018 1:38:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification Form:Addendum for Vacuum/Pressure Interstitial Sensors LG 163-1,Enc 11 <br /> I. Results of Vacuum/Pressure Monitoring Equipment Testing <br /> This page should be used to document testing and servicing of vacuum and pressure interstitial sensors.A copy of <br /> this form must be included with the Monitoring System Certification Form,which must be provided to the tank <br /> system owner/operator.The owner/operator must submit a copy of the Monitoring System Certification Form to the <br /> local agency regulating UST systems within 30 days of test date. <br /> Manufacturer:veeder root Model:330020-463 System Type:r Pressure rV Vacuum <br /> Sensor ID 0 mi <br /> 1 Component(s)Monitored by this Sensor: 87 rod st <br /> Sensor Functionality Test Result:[P Pass r Fail Interstitial Communication Test Result: Pass IV Dail <br /> 2 Component(s)Monitored by this Sensor: 87 vent fill <br /> Sensor Functionality Test Result:P Pass r Fail Interstitial Communication Test Result: - Pass IV I'a I <br /> 3 Component(s)Monitored by this Sensor: yr all udcs <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result:I_ Pass IVO Fail <br /> 4 Component(s)Monitored by this Sensor: 91 rod st <br /> Sensor Functionality Test Result:�Pass r Fail Interstitial Communication Test Result: Pass IV Fail <br /> s5 <br /> Component(s)Monitored by this Sensor. 9 t cent filldsl rod st <br /> Sensor Functionality Test Result:P Pass r Fail Interstitial Communication Test Result: Pass IV Fail <br /> 6 Component(s)Monitored by this Sensor: dsl prod st <br /> Sensor Functionality Test Result:I Pass r Fail Interstitial Communication Test Result:I Pass NO Fail <br /> 7 Component(s)Monitored by this Sensor: dsl fill vent <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result:F P:us ,.o i a i I <br /> Componeut(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result: Pass Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result. _ Pass Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result: __I Pass Fail <br /> How was interstitial communication verified? <br /> Leak Introduced at Far End of Interstitial Spaces r Gauge r Visual Inspection r Other(Describe in Sec.J,below) <br /> Vacuum was restored to operating levels in all interstitial spaces: P Yes r No (Ifno, describe in Sec.J, below) <br /> J.Comments 500 characters max.use additional sheets if needed): <br /> unable to test communication but passed on functionality <br /> Page 4 of 4 <br /> I If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br /> sensor,vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br /> W0: 2330296 <br />
The URL can be used to link to this page
Your browser does not support the video tag.