Laserfiche WebLink
Chevron <br />W I fth, -0. a <br />May 20, 2013 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue <br />Stockton, Ca. 95205 <br />Tel: 209-468-3420 <br />Dear Garrett Backus: <br />Global Marketing <br />©a® <br />oar �amny o! cranes <br />Chevron Corporation <br />6001 Bollinger Canyon Rd. <br />San Ramon, CA. 94583 <br />RECEIVED <br />MAY 2 3 2013 <br />ENVIRONMENTAL HEALTH <br />PERM T /SERVICES <br />This letter is in response to the inspection report issued on April 24, 2013 to Chevron Station # 307709, <br />located at 10858 Trinity Parkway, Stockton, CA. 95219 <br />Below is our response regarding the items noted in the enclosed inspection report. <br />• (203) Diesel fuel was observed today in the under dispenser containments 3 and 11. Any release <br />from the primary containment that does not escape the secondary containment and was cleaned <br />up within 8 hours of being detected shall be recorded. <br />o Please see attached form "Recording Requirements for Unauthorized Releases" <br />Reinspection done on 5/1/13 (attached) <br />• (303) The Diesel fill sump liquid sensor was located approximately six inches off the lowest point of <br />the sump and not located to detect a leak at the earliest opportunity. <br />o On 4/24/13 Tanknology relocated the diesel fill sump sensor at the lowest point of the sump. <br />o Reinspection done on 5/1/13 <br />• (311) The Diesel line leak detector failed to detect a leak when tested. All line leak detectors shall <br />be capable of detecting a 3 gallon per hour leak at 10 psi. <br />o Status in progress. SSS will replace the Diesel turbine assembly, we have ordered the <br />replacement turbine, apparently the vendor (CPE) is currently waiting for the shipment/parts <br />to come in. <br />• (402) Diesel fuel leaks in the form of drips were found at dispensers 3 and 11 in the piping above <br />the shear valve, probably in the meter hardware. A small amount of fuel was observed in the under <br />dispenser containments. <br />o On 4124/13 Tanknology removed the liquid in UDC 3 and UDC 11. <br />o On 4/25/13 SSS tightened the bolts on diesel shear valve on UDC 3 and replaced the meter <br />cover and gasket on UDC 11, no further releases observed. <br />o Reinspection done on 5/1/13 (attached) <br />• (403)A loss of Brine was found by the Designated Operator in the following list of sumps indicating <br />a leak in the annular space of the secondary containment. Brine was added to each sump annular <br />space of the following days; 87 turbine sump (9/21/12, 11/17/12), UDC 7/8 (10/26/12), 91 fill sump <br />(11/17/12), diesel STP (11/17/12), diesel fill (11/17/12), vent sump (11/17/12), UDC %2 (1/23/13). <br />