COMPLIANCE INFO 1988 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ARMY
>
1624
>
2300 - Underground Storage Tank Program
>
PR0231014
>
COMPLIANCE INFO 1988 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2019 2:21:43 PM
Creation date
9/20/2018 11:31:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 1988 - 2006
FileName_PostFix
1988 - 2006
RECORD_ID
PR0231014
PE
2361
FACILITY_ID
FA0003777
FACILITY_NAME
TOYS R US
STREET_NUMBER
1624
STREET_NAME
ARMY
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
16334002
CURRENT_STATUS
01
SITE_LOCATION
1624 ARMY CT
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
289
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TANK ANNULAR TESTING <br />_............ <br />Test Method By: 0 Manufacturer O Industry Standard O Professional Engr. O Other (see below) <br />Test Method Uses o Pressure t Vacuum O Hydrostatic O Other (see below) <br />Measuring Equipment Used: Vacuum Gauge (range 0 to 30 inches Hg) <br />Description <br />Tank #1 <br />Tank Manufacturer <br />Joor <br />Tank Type <br />Steel <br />10,000 <br />Diesel <br />Tank Capacity <br />Product Stored <br />Is this a multi-compartment tank? <br />No <br />Brine filled or Dry Annular? <br />(if brine filled, perform no vacuum testing) <br />Dry <br />Monitoring system show normal annular? <br />Yes <br />Is water table above tank bottom? <br />Unknown <br />Was sensor removed for testing? <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Wait time for vacuum to stabilize (hr:min) <br />0:15 <br />Test start time <br />1:00 AM <br />Initial vacuum (inches Hg) <br />7 <br />Test end time <br />2:00 AM <br />Final vacuum (inches Hg) <br />7 <br />Test duration (hours:minutes) <br />1:00 <br />Change in vacuum (inches Hg) <br />0 <br />Pass/Fail threshold (inches Hg/hour) <br />2 <br />TEST RESULT <br />PASS <br />Comments: <br />O 2002 Walton Engineering, Inc <br />