My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1988 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ARMY
>
1624
>
2300 - Underground Storage Tank Program
>
PR0231014
>
COMPLIANCE INFO 1988 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2019 2:21:43 PM
Creation date
9/20/2018 11:31:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 1988 - 2006
FileName_PostFix
1988 - 2006
RECORD_ID
PR0231014
PE
2361
FACILITY_ID
FA0003777
FACILITY_NAME
TOYS R US
STREET_NUMBER
1624
STREET_NAME
ARMY
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
16334002
CURRENT_STATUS
01
SITE_LOCATION
1624 ARMY CT
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
289
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPENSER CONTAINMENT <br />(UDC) TESTING <br />.............................................. .. <br />...................... <br />.................... <br />Test Method By: . <br />Test Method Uses:? <br />Measuring Equipment Used: <br />O Manufacturer • Industry Standard <br />Pressure _) Vacuum <br />........................................ <br />.................................... <br />Level Change Indicator "< <br />O Professional Engr. O Other (see below) <br />0 Hydrostatic O other (see below) <br />(Caldwell System 2oo1 /waltonEngineering) <br />Description <br />Disp # 1/2 <br />UDC Manufacturer <br />None <br />UDC Material <br />UDC Depth (inches) <br />Height from UDC bottom to highest <br />piping penetration <br />Height from UDC bottom to lowest <br />electrical penetration <br />Condition of UDC prior to testing <br />Portion of UDC tested <br />Type of shut-down present <br />Was sensor removed for testing? <br />Was sensor properly replaced after testing? <br />Wait time for water level to stabilize (hr:min) <br />Depth of water level from UDC bottom (in.) <br />Test start time <br />Test end time <br />Test duration (hr:min) <br />Change in water level (± 0.000 inches) <br />Pass/Fail threshold (0.005 inches/'/2 Hr.) <br />TEST RESULT <br />Comments: <br />There is no UDC at this facility. This is a suction system. <br />Cc 2002 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.