My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 10:44:17 AM
Creation date
9/24/2018 10:40:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.so oq v org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />VALLEY PACIFIC FRESNO AVE CARDLOCK <br />1524 FRESNO AVE STOCKTON <br />March 09 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the May 2016 <br />designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br />missing alarms include: the fuel alarm for the C3 - Satellite 2/3 dispenser pan sensor occurred on 5/6/2016. There <br />were no records of alarm logs or follow up actions for this fuel alarm. During the monthly inspection, the designated <br />operator shall review the alarm history for the previous month, check that each alarm was documented and responded <br />to appropriately, and attach a copy of the alarm history with documentation taken in response to any alarms to the <br />monthly report. Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. <br />This is a minor violation. <br />211 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training was not found on site. The designated operator shall train facility <br />employees for which he or she is responsible in the proper operation and maintenance of the UST system once every <br />12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br />the training records to the EHD. <br />This is a minor violation. <br />315 <br />HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003). <br />Liquid was observed in the STP sump . If water could enter into the secondary containment by precipitation or <br />infiltration, it must be removed and disposed of properly. The service technician removed approximately 1 cup of liquid <br />from the STP sump. Ensure that all sumps and annular spaces are maintained free of liquid. <br />This is a minor violation. <br />319 <br />CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br />The diesel UST spill container failed the one hour hydrostatic test. All USTs shall be equipped with a spill container <br />that has a minimum capacity of five gallons and a drain valve that allows drainage of the collected spill into the primary <br />container or provide a means to keep the container empty. <br />The technician replaced the drain valve. The diesel UST was retested and passed. <br />This was corrected on site. <br />This is a minor violation. <br />Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.