Laserfiche WebLink
aceAnalytical <br />wwwp8cv1aba.com <br />1 <br />QUALITY CONTROL DATA <br />Pace Analytical Services, Inc. <br />2795 Second Street - Suite 300 <br />Davis, CA 95618 <br />(530)297-4800 <br />Project: Valley Pacific Fresno Ave. <br />Pace Project No.: 1263778 <br />MATRIX SPIKE & MATRIX SPIKE <br />DUPLICATE: <br />304957 <br />304958 <br />MS <br />MSD <br />1263477008 <br />Spike <br />Spike <br />MS <br />MSD <br />MS <br />MSD <br />% Rec <br />Max <br />Parameter <br />Units <br />Result <br />Conc. <br />Conc. <br />Result <br />Result <br />% Rec <br />% Rec <br />Limits <br />RPD <br />RPD Qual <br />n-Propylbenzene <br />ug/kg <br /><0.083 <br />39.4 <br />39 <br />35.6 <br />34.3 <br />90 <br />88 <br />30-136 <br />4 <br />25 <br />Naphthalene <br />ug/kg <br /><0.22 <br />39.4 <br />39 <br />36.2 <br />34.6 <br />91 <br />88 <br />30-127 <br />5 <br />25 <br />o -Xylene <br />ug/kg <br />0.18J <br />39.4 <br />39 <br />36.5 <br />35.9 <br />92 <br />92 <br />44-125 <br />2 <br />25 <br />p-Isopropyltoluene <br />ug/kg <br /><2.4 <br />39.4 <br />39 <br />35.0 <br />33.2 <br />89 <br />85 <br />30-136 <br />5 <br />25 <br />sec-Butylbenzene <br />ug/kg <br /><0.086 <br />39.4 <br />39 <br />34.9 <br />33.7 <br />88 <br />86 <br />30-133 <br />3 <br />25 <br />Styrene <br />ug/kg <br /><0.069 <br />39.4 <br />39 <br />36.4 <br />35.3 <br />92 <br />91 <br />30-128 <br />3 <br />25 <br />tert-Butyl benzene <br />ug/kg <br /><0.093 <br />39.4 <br />39 <br />35.2 <br />34.4 <br />89 <br />88 <br />30-129 <br />2 <br />25 <br />Tetrachloroethene <br />ug/kg <br /><0.11 <br />39.4 <br />39 <br />35.8 <br />34.1 <br />91 <br />88 <br />42-125 <br />5 <br />25 <br />Toluene <br />ug/kg <br />0.75J <br />39.4 <br />39 <br />37.2 <br />35.9 <br />92 <br />90 <br />50-125 <br />4 <br />25 <br />trans-1,2-Dichloroethene <br />ug/kg <br /><0.17 <br />39.4 <br />39 <br />35.9 <br />35.1 <br />91 <br />90 <br />57-125 <br />2 <br />25 <br />trans- 1,3-Dichloropropene <br />ug/kg <br /><0.076 <br />39.4 <br />39 <br />33.7 <br />33.5 <br />86 <br />86 <br />33-125 <br />1 <br />25 <br />Trichloroethene <br />ug/kg <br /><0.087 <br />39.4 <br />39 <br />37.4 <br />36.3 <br />95 <br />93 <br />51-125 <br />3 <br />25 <br />Trichlorofluoromethane <br />ug/kg <br /><0.11 <br />39.4 <br />39 <br />33.3 <br />33.3 <br />84 <br />85 <br />54-125 <br />0 <br />25 <br />Vinyl chloride <br />ug/kg <br /><0.19 <br />39.4 <br />39 <br />35.2 <br />34.8 <br />89 <br />89 <br />57-125 <br />1 <br />25 <br />Xylene (Total) <br />ug/kg <br /><0.20 <br />118 <br />117 <br />109 <br />106 <br />92 <br />91 <br />44-125 <br />2 <br />25 <br />1,2-Dichloroethane-d4 (S) <br />%. <br />102 <br />102 <br />70-130 <br />4-Bromofluorobenzene (S) <br />%. <br />96 <br />98 <br />70-130 <br />Toluene -d8 (S) <br />%. <br />100 <br />101 <br />70-130 <br />Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. <br />REPORT OF LABORATORY ANALYSIS <br />This report shall not be reproduced, except in full, <br />Date: 04/13/2016 04:40 PM without the written consent of Pace Analytical Services, Inc.. <br />Page 17 of 26 <br />