COMPLIANCE INFO_2015 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 10:44:17 AM
Creation date
9/24/2018 10:40:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification <br /> A Results of Testing/Servicing <br /> Software Version Installed : 14. 04 <br /> Complete the following checklist : <br /> ® Yes ❑ No * Is the audible alarm operational? <br /> ® Yes ❑ No * Is the visual alarm operational? <br /> El Yes ❑ No * Were all sensors visually inspected, functionally tested, and confirmed operational? <br /> ® Yes ❑ No * Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑ Yes ❑ No * If alarms are relayed to a remote monitoring station, is all communications equipment (e . g . , modem) <br /> ® N/A operational? <br /> ® Yes ❑ No * For pressurized piping systems , does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes : which sensors initiate <br /> positive shut-down? (Check all that apply) ® Sump/Trench Sensors ; ® Dispenser Containment Sensors . <br /> Did you confirm positive shut- down due to leaks and sensor failure/disconnection? ® Yes; ❑ No . <br /> ❑ Yes ❑ No * For tank systems that utilize the monitoring system as the primary tank overfill warning device (i . e . , no <br /> ® N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point( s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? % <br /> ❑ Yes * ® No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E, below. <br /> ❑ Yes * ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑ Product; ❑ Water. If yes, describe causes in Section E, below. <br /> ® Yes ❑ No Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br /> ® Yes ❑ No * Is all monitoring equipment operational per manufacturer' s specifications? <br /> x In Section E below, describe how and when these deficiencies were or will be corrected. <br /> E . Comments : <br /> UN-036 — www. unidoes. org Rev. 01/17/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.