My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 10:44:17 AM
Creation date
9/24/2018 10:40:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB , January 2002 Page 4 of _7_ <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By : ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br /> ❑ Other (Sped) <br /> Test Method Used : ❑ Pressure ❑ Vacuum ® Hydrostatic <br /> ❑ Other (Sped) <br /> Test Equipment Used : INCON SUMP TESTER Equipment Resolution : 0 . 002" <br /> Sump # Diesel STP Sump # Sump # Sump # <br /> Sump Diameter: 42" <br /> Sump Depth : 49" l <br /> Sump Material : Fiberglass <br /> Height from Tank Top to Top of 2211 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 14" <br /> p3 <br /> Electrical Penetration : <br /> Condition of sump prior to testing: Dry <br /> Portion of Sump Tested ' 2 " / Penetrations <br /> Does turbine shut down when <br /> sump sensor detects liquid (both ®yes ❑ No [:INA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No [:INA ❑ Yes ❑ No ❑ NA <br /> product and water)? ` <br /> Turbine shutdown response time 4 seconds <br /> Is system programmed for fail-safe <br /> shutdown? ' ® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br /> Was fail-safe verified to be ® Yes ❑ No [] No NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No NA ❑ Yes ❑ <br /> NA <br /> operational? <br /> Wait time between applying <br /> pressure/vacuum/water and starting 10 min. <br /> test: <br /> Test Start Time : 11 : 50am <br /> Initial Reading (Rj) : 6 .4397" <br /> Test End Time : 12 : 06pm <br /> Final Reading (RF) : 6 .4393" <br /> Test Duration : 15 min . <br /> Change in Reading (RF-RI) : -0 .0004" <br /> Pass/Fail Threshold or Criteria : +/- 0. 002" +/- 0 .002" +/- 0 . 002" +/- 0. 002" <br /> Test Result : ® Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Was sensor removed for testing? ® Yes [:] No ❑ NA [:] Yes ❑ No [:INA ❑ Yes ❑ No [:INA ❑ Yes ❑ No ❑ NA <br /> Was sensor properly replaced and <br /> verified functional after testing? ® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br /> Comments — (inchrde information on repairs made prior to testing, and recommended follolw -up for failed tests) <br /> ' If the entire depth of the sump is not tested, specify how much was tested . If the answer to any of the questions indicated with an <br /> asterisk ( *) is "NO" or "NA" , the entire sump must be tested . ( See SWRCB LG - 160) <br />