SHAUN Environmental Health Department <br /> Cr T Y --_ <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VALLEY PACIFIC FRESNO AVE CARDLOCK 1524 FRESNO AVE, STOCKTON January 16, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> Liquid was observed in the under dispenser containment(UDC)in dispenser#1 and#1 satellite and the fuel piping <br /> in UDC#1 appears to be weeping, indicating a leak in the primary piping. All primary containment for the UST <br /> system must be tight. Immediately have a properly licensed,trained, and certified contractor repair or replace the <br /> failed component under permit and inspection of the EHD.The technicians on site removed the liquid all the area of <br /> concern and tightened the fuel piping thread. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the under dispenser containment(UDC)dispenser#1,#1 satellite, and the turbine <br /> submersible pump(STP)sump. If water could enter into the secondary containment by precipitation or infiltration, it <br /> must be removed and disposed of properly. The service technician removed 1/2 cup of liquid from UDC#1, 3 cups <br /> of liquid from UDC#1 satellite, and 4 tablespoons from the STP sump. Ensure that all sumps and annular spaces <br /> are maintained free of liquid. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by February 15, 2018. <br /> Documents reviewed by regulator: Monitoring plan, response plan, financial documents, employee training log, <br /> designated operator monthly reports, monitoring system certification reports (2015, 2016, 2017), secondary <br /> containment testing reports (2015, 2016), 2017 operating permit. <br /> Documents received by operator: Return to compliance certification form and inspection report. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> FA0007491 PR0506545 SCO02 01/16/2018 <br /> EHD 23-01 Rev.10131/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />