Laserfiche WebLink
10/10/2014 02:58PM 6616349233 KERN CONSTRUCTION PAGE 03/05 <br />SWRCB, January 2002 <br />5. UNDER -DISPENSER <br />Test Method Developed By: ❑ UDC Manufacturer <br />Page 7 of <br />TAINMENT (UDC) TESTING <br />x Industry Standard ❑ Professional Engineer <br />U vmer ppe eyy/ <br />Test Method Used: 0 Pressure ❑ Vacuum <br />x Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Incon TS -STS <br />Equipment Resolution:.001" <br />UDC #112 UDC #3/4 <br />UDC # UDC # <br />UDC Manufacturer: Bravo Bravo <br />UDC Material: FRP FRP <br />U DC Depth: 30" 30" <br />Height from UDC Bottom to Top 12 12" <br />_ <br />of Highest Pipina Penetration: l0" 10" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration:tN <br />Condition of UDC prior to Clean Clean <br />DEPART <br />1A EALTH <br />testin <br />Portion of UDC Tested' 1/2 112 <br />Does turbine shut down when X Yes D No ❑ X Yes ❑ No ❑ <br />UDC sensor detects liquid (both NA NA <br />[]Yes ❑ No ❑ NA <br />p Yes ❑ No ❑ <br />NA <br />product and water)?* <br />3 sec <br />X Yes D No D <br />NA <br />3 Sec. <br />X Yes ❑ No ❑ <br />NA <br />p Yes ❑ No ❑ <br />NA <br />f[E fsD No ❑safe <br />A <br />Turbine shutdown response time <br />Is system programmed for fail- <br />shutdown?' <br />X Yes D No ❑ <br />NA <br />X Yes ❑ No ❑ <br />NA <br />[]Yes ❑ No ❑ NA <br />Yes ❑ No ❑ <br />NA <br />Was fail-safe verified to be <br />operational?* <br />W;tnebetween applying <br />15 min. <br />15 Min. <br />pracuum/water and <br />stastTeTune: <br />Reading M):4.874 <br />12:47 <br />11:58 <br />0.119 <br />Initial <br />Test End Time: <br />Reading (RF): <br />1:02 <br />4.874 <br />12:13 <br />0.119 <br />Final <br />15 Min <br />0 <br />0.002 <br />X Yes ❑ No ❑ <br />15 Min. <br />0 <br />0.002 <br />X Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />Test Duration: <br />Change in Reading (RF-Rr) <br />Pass f 'ail Threshold or Criteria <br />;:Test ,Result .- _ <br />Was sensor removed for testing? <br />NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />X Yes ❑ No ❑ <br />NA <br />X Yes ❑ No ❑ NA <br />❑ Yes D No ❑ NA�Ures <br />❑ No�DNA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />Received Time Oct,10. 2014 3:57PM No.7310 <br />