COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JAHANT
>
17300
>
2800 - Aboveground Petroleum Storage Program
>
PR0522199
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 2:16:01 PM
Creation date
9/25/2018 9:54:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0522199
PE
2832
FACILITY_ID
FA0010336
FACILITY_NAME
GEORGE REED INC
STREET_NUMBER
17300
STREET_NAME
JAHANT
STREET_TYPE
Rd
City
CLEMENTS
Zip
95227
APN
02113011
CURRENT_STATUS
01
SITE_LOCATION
17300 Jahant Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />COUNTY - <br />Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />GEORGE REED INC <br />17300 Jahant Rd, CLEMENTS <br />March 14, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />618 <br />CFR 112.7(e), 112.8(c)(6) Failed to keep records of procedures, inspections, or integrity tests for three years. <br />Site personnel indicated that integrity tests were completed within the last three years during the site visit by a <br />consultant. Copies of the formal integrity test records were not found on site. Inspections and tests must be <br />conducted in accordance with the written procedures developed in the Spill Prevention, Control, and <br />Countermeasure (SPCC) Plan. Records of these inspections and tests must be signed by the appropriate <br />supervisor or inspector and kept on site with the SPCC Plan for a period of three years. Immediately locate a copy <br />of all integrity testing records for the last three years, maintain them on site, and submit copies to the EHD. <br />This is a Class II violation. <br />710 <br />CFR 112.8(c)(6) Plan failed to adequately discuss procedures to test or inspect each container for integrity. <br />The site's current Spill Prevention, Control, and Countermeasure Plan failed to indicate the formal integrity test <br />schedule for each tank. Each aboveground container shall be tested and inspected for integrity on a regular <br />schedule and whenever repairs are made. The qualifications of personnel performing tests and inspections, <br />frequency and type of testing and inspections that take into account container size, configuration, and design shall <br />be determined in accordance with industry standards. Examples of these integrity tests include, but are not limited <br />to: visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other <br />systems of non-destructive testing. Comparison records and other records of inspections and tests must be <br />maintained on site. Immediately conduct the necessary testing or submit a copy of the test results to the EHD, or <br />provide equivalence as allowed by CFR 112.7(a)(2). <br />This is a Class II violation. <br />715 <br />CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation. <br />Upon review of the monthly, and annual electronic inspections records, inspections for liquid level sensing devices <br />are not being documented. Procedures and frequency of testing for these devices were not addressed in the Spill <br />Prevention, Control, and Countermeasure (SPCC) plan. Liquid level sensing devices must be installed in <br />accordance with CFR 112.8 and shall be regularly tested to ensure proper operation. Immediately conduct all <br />necessary testing of liquid level sensing devices, or provide equivalence as allowed by CFR 112.7(a)(2). <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, within 30 days of receipt of this report. <br />Please be aware as of January 1, 2013, all businesses are required to submit all new (or any changes to <br />existing) Aboveground Petroleum Storage Act (APSA) information online to the California Environmental <br />Reporting System (CERS) at http://cers.calepa.ca.gov in addition to any other relevant activities and required <br />fields. No later than January 1, 2014, all APSA data must be entered and or updated in CERS. <br />FA0010336 PR0522199 SCO01 03/14/2018 <br />EHD 28-01 Rev. 11/07/2017 Page 5 of 6 Aboveground Petroleum Storage Act OIR <br />1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.