COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2700
>
2800 - Aboveground Petroleum Storage Program
>
PR0527774
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/21/2019 1:14:53 PM
Creation date
9/27/2018 4:48:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0527774
PE
2834
FACILITY_ID
FA0007644
FACILITY_NAME
BET STOCKTON TERMINAL
STREET_NUMBER
2700
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14503009
CURRENT_STATUS
01
SITE_LOCATION
2700 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> BET STOCKTON TERMINAL ^?^n �!%!kn 'inICTON ST STOCKTOnI �iry 07 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> CFR 112.7(e) Failed to conduct inspections or maintain records for 3 years. <br /> tie Inspection TorrTis eeing usea are not the Torras proviaea oy lacillty Spill Prevention, Control, and <br /> Countermeasure (SPCC) Plan, and in some instances, do not contain the same information. The facility is using <br /> "Monthly In-Service Vertical Aboveground Atmospheric Tank Inspection Forms".The form being used does not <br /> contain everything that the facility SPCC plan contains in Figure 4.1-2-Inspection Procedures which itemizes what <br /> should be inspected during the routine visual inspection and annual inspections. Inspections and tests must be <br /> conducted and stored in accordance with the written procedures developed for this facility in the SPCC Plan. <br /> Immediately begin conducting all inspections and tests in accordance with the procedures in the SPCC Plan, or <br /> amend the Plan and have it recertified by a Professional Engineer to accurately reflect the inspection procedures <br /> currently followed at the facility. <br /> This is a Class 11 violation. <br /> 14 CFR 112.7(0(1) Failed to train personnel on discharge prevention. <br /> The docuii c�ritation for oil handliiiy T u+su inui Liauuilg un tmi iau;ury Spill Prevention Control and Counter Meabi;ic <br /> Plan were not provided upon request during the inspection. At a minimum, oil handling personnel shall be trained +° <br /> the operation and maintenance of equipment to prevent discharges; discharge procedure protocols; applicable <br /> pollution control laws, rules, and regulations; general facility operations; and the contents of the Spill Prevention <br /> Control, and Countermeasure Plan. Immediately provide this training to all oil handling personnel and submit a cup, <br /> of the training log to the EHD. <br /> This is a Class 11 violation. <br /> CFR 112.8(c)(2) Diked area is not sufficiently impervious to contain discharged oil. <br /> The secondary containment wall for the tank i.: i is not impervious to contain discharged oil. The existing <br /> secondary containment has a hole approximately two inches in diameter. This hole has a cable running through it <br /> towards the rail spur which is just north of the tank farm secondary containment wall. Along the north and west walls <br /> of the tank farm secondary containment were multiple seams that had been repaired but now appear to be in <br /> disrepair. One of the repaired seams along the northern part of the wall is wide enough that you can see right <br /> through the wall to the other side. Diked areas must be sufficiently impervious to contain discharged oil. <br /> Immediately provide or repair all diked areas to be sufficiently impervious to contain oil. <br /> This is a Class II violation. <br /> Received by Inspector: Phone: -Bate: <br /> (initial): c-r r -rFR4 SPrinr RFHS 8-?440 11/07/2016 <br /> Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.