Laserfiche WebLink
San Joaquin County�A <br />Environmental Health Department 3UL 1 2018 <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd , NMENTAL <br /><._ limp <br />Aboveground Petroleum Storage Act Inspection Re <br />Facility Name: <br />WILLIAMS TANK LINES <br />Facility Phone: <br />209 944-5613 <br />Date: <br />Aril 14 2015 <br />Facility Address: <br />1477 TILLIE LEWIS DR STOCKTON CA 95206 <br />CERS ID: <br />10183659 <br />Inspection Contact: <br />Garth Williiams <br />Title: <br />Maintenance Mana er <br />Phone: <br />209 944-5613 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />12832-ASTFAC 10 K- </=100 K GAL CUMULATIVE <br />Consent For: Consent Given By: <br />Inspection Photos Sampling Garth Williiams Maintenance Mana er <br />CCR = California Code of Regulations HSC =Health and Safety Code CFR =Code of Federal Regulations <br />V =Violation R =Repeat violation COS = Corrected on site during inspection <br />C <br />101 HSC 25270.4.5(a) Failed to prepare and implement a written SPCC Plan in accordance with CFR Part 112 Cl V ❑ R ❑ COS <br />102 <br />HSC 25270.4.5(a) Failed to properly close a tank that is considered permanently closed ❑ V ❑ R ❑ COS <br />103 <br />HSC 25270.6(a) Failed to file Business Plan or annual facility tank statement if capacity is over 10,000 gallons ❑ V ❑ R ❑ COS <br />104 <br />HSC 25270.6(b) Failed to submit APSA fees ❑ V ❑ R o COS <br />25270.8 Failed to report spills or releases of 42 gallons (one barrel) or more ❑ V ❑ R ❑ COS <br />CCR 25185(c)(3) Failed to submit a written response within 30 days of receiving an inspection report ❑ V ❑ R ❑ COS <br />HSC 25404(e)(4) Failed to report program data electronically ❑ V ❑ R ❑ COS <br />JHSC <br />Requirement to Prepare andyImpl to SPCC Plan. <br />CFR 112.3(d) Plan certification by a Professional Engineer (PE) missing or incomplete ❑ V ❑ R ❑ COS <br />CFR 112.3(e)(1) Failed to maintain a copy of the Plan on site ❑ V ❑ R ❑ COS <br />Amendment of SPCC Pari by Owners or Operators <br />301 CFR 112.5(a) Failed to amend Plan as necessary _ ■ V ❑ R ❑COS <br />302 CFR 112.5(b) Failed to review Plan once every five years and/or implement any resulting amendments <br />■ V ❑ R ❑ COS <br />303 CFR 112.5(c) Failed to have a PE certify technical amendments ❑ V ❑ R ❑ COS <br />e.- General Requirements for SPCC Plans <br />601 <br />CFR 112.7 Plan that does not follow the sequence specified in this section lacks a cross-referencing section <br />❑ V ❑ R ❑ COS <br />602 <br />CFR 112.7 Plan lacks approval of management to fully commit the necessary resources to implement the Plan <br />❑ V ❑ R ❑ COS <br />603 <br />CFR 112.7(a)(2) Plan failed to discuss equivalent environmental protection, if applicable <br />❑ V ❑ R ❑COS <br />604 <br />CFR 112.7(a)(3) No facility diagram or didn't show location and contents of containers, transfer stations, and pipes <br />❑ V ❑ R ❑ COS <br />605 <br />CFR 112.7(a)(3) Plan failed to address facility layout, operations discharge prevention methods and containers <br />❑ V ❑ R ❑COS <br />606 <br />CFR 112.7(a)(4) Plan failed to contain procedures for reporting a discharge <br />❑ V ❑ R ❑ COS <br />607 <br />CFR 112.7(a)(5) Discharge procedures are not adequately addressed if the facility has no response plan <br />❑ V ❑ R ❑ COS <br />608 <br />CFR 112.7(b) Plan failed to include a description of potential equipment failure or provide equivalence <br />❑ V ❑ R ❑COS <br />609 <br />CFR 112.7(c) Failed to provide secondary containment, diversionary structures, or equipment to prevent discharge <br />❑ V ❑ R ❑ COS <br />610 <br />CFR 112.7(d) Full or partial PE certified Plan failed to explain impracticability <br />❑ V ❑ R ❑ COS <br />611 <br />CFR 112.7(d)(1) Full or partial PE certified Plan failed to include spill contingency if no response plan submitted <br />❑ V ❑ R ❑ COS <br />612 <br />CFR 112.7(d)(2) No written commitment of manpower, equipment, and materials to control and remove oil discharge <br />❑ V ❑ R ❑ COS <br />Received by <br />(initial): <br />Inspector: <br />STACY RIVERA, Senior REHS <br />Phone: <br />(209) 468-3440 <br />Date: <br />04/14/2015 <br />Page 1 of 6 <br />