Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TILLIE LEWIS
>
1477
>
2800 - Aboveground Petroleum Storage Program
>
PR0523160
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 10:31:53 AM
Creation date
10/2/2018 11:28:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0523160
PE
2832
FACILITY_ID
FA0010602
FACILITY_NAME
WILLIAMS TANK LINES
STREET_NUMBER
1477
STREET_NAME
TILLIE LEWIS
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
16336003
CURRENT_STATUS
01
SITE_LOCATION
1477 TILLIE LEWIS DR
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
129
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin CountyRE�JV <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 JUL 11 2018 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Aboveground Petroleum Storage Act Inspection Repo, <br />Facility Name: <br />WILLIAMS TANK LINES <br />Facility Address: <br />1477 TILLIE LEWIS DR STOCKTON <br />Date: <br />A ril 14 2015 <br />G eneral R qulrer PCC Plans <br />613 <br />CFR 112.7(e) <br />Failed to conduct inspections or maintain records for 3 years <br />■ V o R o COS <br />614 <br />CFR 112.7(f)(1) <br />Failed to train personnel on discharge prevention <br />■ V o R D COS <br />615 <br />CFR 112.7(f)(2) <br />Failed to designate a person accountable for discharge prevention <br />D V D R o COS <br />616 <br />CFR 112.7(0(3) <br />Failed to schedule and conduct discharge prevention briefings at least annually <br />■ V o R D COS <br />617 <br />CFR 112.7(g) <br />Plan failed to address security of site and valves, lock out/tag out, and lighting o V o R o COS <br />618 <br />CFR 112.7(h)(1) <br />Loading/unloading rack containment system not properly sized D V D R D COS <br />619 <br />CFR 112.7(h)(2) <br />Failed to provide vehicular departure system loading and unloading racks o V D R o COS <br />620 <br />CFR 112.7(h)(3) <br />Failed to inspect lowermost drains and outlets prior to filling and departure of vehicles o V D R o COS <br />621 <br />CFR 112.7(1) <br />Failed to evaluate field constructed container for brittle fracture and take appropriate action D V D R D COS <br />622 <br />CFR 112.70) <br />Failed to include discussion of conformance to discharge prevention and containment procedures o V D R D COS <br />roctioMf llif, es) <br />SPCC%Plan Requirements for Onshore Facilities (excluding pdu <br />CFR 112.8(b)(2) <br />Failed to use manual open -and -closed design valves for the drainage of diked areas <br />o V D R o COS <br />7702 <br />CFR 112.8(b)(3), <br />112.8(b)(4) <br />Failed to design facility drainage system from undiked areas to retain in the facility <br />o V o R o COS <br />703 <br />CFR 112.8(b)(5) <br />Failed to provide two lift pumps for more than one continuous treatment unit <br />D V D R D COS <br />704 <br />CFR 112.8(c)(2) <br />Diked area is not sufficiently impervious to contain discharged oil <br />o V o R D COS <br />705 <br />CFR 112.8(c)(1) <br />Container not compatible with oil stored and/or storage conditions <br />D V o R D COS <br />706 <br />CFR 112.8(c)(2) <br />Failed to provide and maintain adequate secondary containment <br />o V o R D COS <br />707 <br />CFR 112.8(c)(3)(i) <br />Failed to keep containment bypass valves closed when not draining rainwater <br />D V o R o COS <br />708 <br />CFR 112.8(c)(3)(ii) <br />Failed to inspect retained rainwater prior to discharge <br />o V o R D COS <br />709 <br />CFR 112.8(c)(3)(iii) <br />Failed to open and close bypass valve to drain rainwater under responsible supervision <br />o V o R D COS <br />710 <br />CFR 112.8(c)(3)(iv) <br />Failed to maintain records of drainage from diked areas <br />D V o R D COS <br />711 <br />CFR 112.8(c)(5) <br />Failed to provide corrosion protection for partially buried tanks <br />o V o R o COS <br />712 <br />CFR 112.8(c)(6) <br />Failed to perform tank inspections that take into account size, configuration, and design <br />o V D R D COS <br />713 <br />CFR 112.8(c)(6) <br />Failed to perform scheduled tank tests and inspections by appropriately qualified personnel <br />■ V o R D COS <br />714 <br />CFR 112.8(c)(6) <br />Failed to test and inspect containers by appropriately qualified personnel after material repairs <br />o V D R D COS <br />715 <br />CFR 112.8(c)(7) <br />Failed to provide effective leakage control through defective internal heating coils <br />D V D R o COS <br />716 <br />CFR 112.8(c)(8)(i-iv) <br />Failed to provide each container with a high level monitoring device <br />o V o R o COS <br />717 <br />CFR 112.8(c)(8)(v) <br />Failed to regularly test liquid level sensing devices to ensure proper operation <br />■ V ■ R o COS <br />718 <br />CFR 112.8(c)(9) <br />Failed to observe effluent treatment frequently enough to detect potential discharge <br />o V o R D COS <br />719 <br />CFR 112.8(c)(10) <br />Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas <br />❑ V o R ❑COS <br />720 <br />CFR 112.8(c)(11) <br />Failed to provide sufficient secondary containment capacity for mobile or portable containers <br />■ V ■ R D COS <br />721 <br />CFR 112.8(c)(11) <br />Failed to locate mobile or portable containers to prevent discharge <br />o V D R o COS <br />722 <br />CFR 112.8(d)(1) <br />Failed to take corrective action on buried piping when exposed for any reason <br />o V o R D COS <br />Received byInspector: <br />(initial): &qM (`-�' 1 <br />nD <br />STACY RIVERA, Senior REHS <br />Phone: <br />t(209) 468-3440 <br />Date: <br />04/14/2015 <br />Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.