My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
STANISLAUS
>
1176
>
2800 - Aboveground Petroleum Storage Program
>
PR0528253
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2019 4:28:59 PM
Creation date
10/10/2018 10:19:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528253
PE
2832
FACILITY_ID
FA0003822
FACILITY_NAME
ESCALON UNIFIED SCHOOL DIST
STREET_NUMBER
1176
STREET_NAME
STANISLAUS
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22705007
CURRENT_STATUS
01
SITE_LOCATION
1176 STANISLAUS ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAN I N <br />Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />ESCALON UNIFIED SCHOOL DIST <br />1176 STANISLAUS ST, ESCALON <br />July 16, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />714 <br />CFR 112.8(c)(8)(i-iv) Failed to provide each container with a high level monitoring device. <br />The SPCC plan states that all tanks are equipped with with direct reading level gauges and high level alarms. None <br />of the tanks were observed with both systems and only the two used oil containers were observed with level gauges. <br />At least one of the following devices must be installed in each container: <br />- High liquid level alarm with audible or visual signal <br />- High liquid level pump cutoff device set to stop flow at a predetermined content level <br />- Direct audible or code signal communication between the container gauger and the pumping station <br />- Fast response system, such as digital computer, telepulse, or direct vision gauge. If a direct vision gauge is <br />being used for determining the liquid level of each tank, a person must be present to monitor gauges and the overall <br />filling of the tanks. <br />Immediately install an approved liquid level sensing device in accordance with CFR 112.8 and implement necessary <br />procedures to ensure that the devices are fully functional and in use at all times during tank filling operations, or <br />provide equivalence as allowed by CFR 112.7(a)(2). <br />This is a Class II violation. <br />715 <br />CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation. <br />Liquid level sensing devices have not been tested for any of the tanks regulated under APSA/SPCC requirements. <br />Procedures and frequency of testing for these devices were not addressed in the Spill Prevention, Control, and <br />Countermeasure (SPCC) plan. Liquid level sensing devices must be installed in accordance with CFR 112.8 and <br />shall be regularly tested to ensure proper operation. Immediately conduct all necessary testing of liquid level <br />sensing devices, or provide equivalence as allowed by CFR 112.7(a)(2). <br />This is a Class II violation. <br />720 <br />CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping. <br />Evidence of buried piping was observed at the facility and was corrosion protection was not addressed in the SPCC <br />plan. Buried piping that is installed or replaced after August 16, 2002, shall be provided with a protective wrapping <br />and coating and cathodically protected. Immediately provide all buried piping installed on or after August 16, 2002, <br />a protective wrapping and coating and cathodic protection. <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork by August 15, 2018. <br />Please be aware as of January 1, 2013, all businesses are required to submit all new (or any changes to <br />existing) Aboveground Petroleum Storage Act (APSA) information online to the California Environmental <br />Reporting System (CERS) at http://cers.calepa.ca.gov in addition to any other relevant activities and required <br />fields. No later than January 1, 2014, all APSA data must be entered and or updated in CERS. <br />EHD 28-01 Rev. 11/07/2017 <br />Page 7 of 8 <br />FA0003822 PR0528253 SCO01 07/16/2018 <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 <br />Aboveground Petroleum Storage Act OIR <br />www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.