My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
STANISLAUS
>
1176
>
2800 - Aboveground Petroleum Storage Program
>
PR0528253
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2019 4:28:59 PM
Creation date
10/10/2018 10:19:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528253
PE
2832
FACILITY_ID
FA0003822
FACILITY_NAME
ESCALON UNIFIED SCHOOL DIST
STREET_NUMBER
1176
STREET_NAME
STANISLAUS
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22705007
CURRENT_STATUS
01
SITE_LOCATION
1176 STANISLAUS ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />ESCALON UNIFIED SCHOOL DIST <br />Facility Address: <br />1 1176 STANISLAUS ST, ESCALON <br />Date: <br />July 16, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />618 <br />CFR 112.7(e), 112.8(c)(6) Failed to keep records of procedures, inspections, or integrity tests for three years. <br />The inspection forms being used are not the forms provided by Spill Prevention, Control, and Countermeasure <br />(SPCC) Plan, and in some instances, do not contain the same information. The forms presented as inspections <br />meeting the SPCC requirements were labeled as Vapor Recovery Inpections. Inspections and tests must be <br />conducted and stored in accordance with the written procedures developed for this facility in the SPCC Plan. <br />Immediately begin conducting all inspections and tests in accordance with the procedures in the SPCC Plan, or <br />amend the Plan and have it recertified by a Professional Engineer to accurately reflect the inspection procedures <br />currently followed at the facility. <br />This is a Class II violation. <br />619 <br />CFR 112.7(0(1) Failed to train personnel on all discharge prevention details listed in this section. <br />Oil handling personnel were not trained or logs of trainings were not kept as described in the SPCC plan. At a <br />minimum, oil handling personnel shall be trained in the operation and maintenance of equipment to prevent <br />discharges; discharge procedure protocols; applicable pollution control laws, rules, and regulations; general facility <br />operations; and the contents of the Spill Prevention, Control, and Countermeasure Plan. Immediately provide this <br />training to all oil handling personnel and submit a copy of the training log to the EHD. <br />This is a Class II violation. <br />622 <br />CFR 112.7(0(3) Failure to conduct complete annual discharge prevention briefings for oil -handling personnel. <br />Discharge prevention briefings are not scheduled at least once a year. Discharge prevention briefings for oil <br />handling personnel must be scheduled and conducted at least once a year to assure adequate understanding of the <br />SPCC Plan for that facility. Such briefings must highlight and describe known discharges or failures, malfunctioning <br />components, and any recently developed precautionary measures. Immediately schedule and conduct a discharge <br />prevention briefing, ensure that they are scheduled and conducted at least once a year. <br />This is a minor violation. <br />710 <br />CFR 112.8(c)(6) Plan failed to adequately discuss procedures to test or inspect each container for integrity. <br />The referenced industry standard STI SP001 frequency of formal inspections is not mentioned in the SPCC plant. <br />The the size, configuration, or design of the tank must be taken into consideration for formal inspections under <br />industry standards. Each aboveground container shall be tested and inspected for integrity on a regular schedule <br />and whenever repairs are made. The qualifications of personnel performing tests and inspections, frequency and <br />type of testing and inspections that take into account container size, configuration, and design shall be determined <br />in accordance with industry standards. Examples of these integrity tests include, but are not limited to: visual <br />inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other systems <br />of non-destructive testing. Comparison records and other records of inspections and tests must be maintained on <br />site. Immediately conduct the necessary testing and submit a copy of the test results to the EHD, or provide <br />equivalence as allowed by CFR 112.7(a)(2). <br />This is a Class II violation. <br />FA0003822 PR0528253 SCO01 07/16/2018 <br />EHD 28-01 Rev. 11/07/2017 Page 6 of 8 Aboveground Petroleum Storage Act OR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.