Laserfiche WebLink
Page 2of5 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www sigov org/ehd <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />I',-nske Truck !_ <br />cj Co LP <br />Facility Address: <br />-n Rd Stockton <br />Date: <br />March 20 2015 <br />General Requirements for SPCC Plans <br />613 <br />CFR 112.7(e) <br />Failed to conduct inspections or maintain records for 3 years <br />❑ V ❑ R ❑ COS <br />614 <br />CFR 112.7(0(1) <br />Failed to train personnel on discharge prevention <br />❑ V ❑ R ❑ COS <br />615 <br />CFR 112.7(f)(2) <br />Failed to designate a person accountable for discharge prevention <br />❑ V o R o COS <br />616 <br />CFR 112.7(f)(3) <br />Failed to schedule and conduct discharge prevention briefings at least annually <br />o V ❑ R ❑ COS <br />617 <br />CFR 112.7(g) <br />Plan failed to address security of site and valves, lock out/tag out, and lighting <br />o V o R ❑ COS <br />618 <br />CFR 112.7(h)(1) <br />Loading/unloading rack containment system not properly sized <br />❑ V o R o COS <br />619 <br />CFR 112.7(h)(2) <br />Failed to provide vehicular departure system loading and unloading racks <br />o V ❑ R ❑ COS <br />620 <br />CFR 112.7(h)(3) <br />Failed to inspect lowermost drains and outlets prior to filling and departure of vehicles <br />❑ V o R o COS <br />621 <br />CFR 112.7(1) <br />Failed to evaluate field constructed container for brittle fracture and take appropriate action <br />o V ❑ R o COS <br />622 <br />CFR i12.70) <br />Failed to Include discussion of conformance to discharge prevention and containment procedures <br />o V ❑ R ❑ COS <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br />701 <br />CFR 112.8(b)(2) <br />Failed to use manual open-and-closed design valves for the drainage of diked areas <br />❑ V a R n COS <br />702 <br />CFR 112.8(b)(3), <br />112.8(b)(4) <br />Failed to design facility drainage system from undiked areas to retain in the facility <br />❑ V o R o COS <br />703 <br />1 CFR 112.8(b)(5) <br />Failed to provide two lift pumps for more than one continuous treatment unit <br />❑ V ❑ R ❑ COS <br />704 <br />CFR 112,8(c)(2) <br />Diked area Is not sufficiently impervious to contain discharged oil <br />❑ V ❑ R o COS <br />705 <br />CFR 112.8(c)(1) <br />Container not compatible with oil stored and/or storage conditions <br />❑ V ❑ R ❑ COS <br />706 <br />CFR 112.8(c)(2) <br />Failed to provide and maintain adequate secondary containment <br />❑ V ❑ R ❑ COS <br />707 <br />CFR 112.8(c)(3)(i) <br />Failed to keep containment bypass valves closed when not draining rainwater <br />u V o R u COS <br />708 <br />GFR 112.8(c)(3)(11) <br />Failed to inspect retained rainwater prior to discharge <br />❑ V ❑ R u COS <br />709 <br />CFR 112.8(c)(3)(!il) <br />Failed to open and close bypass valve to drain rainwater under responsible supervision <br />❑ V ❑ R u COS <br />710 <br />CFR 112,8(c)(3)(iv) <br />Failed to maintain records of drainage from diked areas <br />❑ V ❑ R c COS <br />711 <br />CFR 112.8(c)(5) <br />Failed to provide corrosion protection for partially buried tanks <br />o V o R o COS <br />712 <br />CFR 112.8(c)(6) <br />Failed to perforin tank inspections that take into account size, configuration, and design <br />o V n R ❑ COS <br />713 <br />CFR 112.8(c)(6) <br />Failed to perform scheduled tank tests and inspections by appropriately qualified personnel <br />■ V ■ R o COS <br />714 <br />CFR 112.8(c)(6) <br />Failed to test and inspect containers by appropriately qualified personnel after material repairs <br />o V ❑ R o COS <br />715 <br />CFR 112.8(e)(7) <br />Failed to provide effective leakage control through defective internal heating coils <br />❑ V ❑ R ❑ COS <br />716 <br />CFR 112.8(c)(8)(i-Iv) Failed to provide each container with a high level monitoring device <br />o V ❑ R o COS <br />717 <br />1 CFR 112.8(c)(B)(v) <br />Failed to regularly test liquid level sensing devices to ensure proper operation <br />❑ V o R c COS <br />718 <br />CFR 112.8(c)(9) <br />Failed to observe effluent treatment frequently enough to detect potential discharge <br />o V o R o COS <br />719 <br />CFR 112.8(c)(10) <br />Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas <br />u V ❑ R a COS <br />720 <br />CFR 112.8(c)(11) <br />Failed to provide sufficient secondary containment capacity for mobile or portable containers <br />a V ❑ R in COS <br />721 <br />CFR 112.8(c)(11) <br />Failed to locate mobile or portable containers to prevent discharge <br />❑ V o R o COS <br />722 <br />CFR 112.8(d)(1) <br />Failed to take corrective action on buried piping when exposed for any reason <br />❑ V o R n COS <br />Received byInspector: <br />(initial): <br />STAC Y RIVERA, Senior REHS <br />Phone: <br />)9) 468-3440 <br />DOW <br />03/20!201,1) <br />Page 2of5 <br />