Laserfiche WebLink
Nagesoro <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.oralehci <br />Aboveground Petroleum Storage Act Inspection Report <br />FacilityName: Facility Addross: TD.te- <br />;63 1 •tor, arch 20, 2015 <br />:SinoCo.,LP <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br />723 1 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping a V o R o COS <br />724 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark Its origin if not in service o V a R o COS <br />725 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction o V o R a COS <br />726 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves, piping, and appurtenances a V o R o COS <br />727 CFR 112.8(d)(4) Failed to conduct integrity and leak test on buried piping any time it is worked on o V o R o COS <br />728 CFR 112,8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations o V o R o COS <br />Other Violations <br />4010 1 See below Unlisted Administration/Documentation violation o V a R o COS <br />4020 See below Unlisted Training violation u V ❑ R o COS <br />4030 See below Unlisted Operations/Maintenence violation a V a R o COS <br />4040 See below I Unlisted ReleaselLeaks/Spilis violation o V o R o COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />30'1 <br />CFR 112.5(a) Failed to amend Plan as necessary. <br />The SPCC Plan discusses tanks that could not be found at this facility The Plan repeatedly references underground <br />storage tanks, gasoline tanks, and underground piping, Including a detailed description of the underground storage <br />tank monitoring. According to Mr. Haylett, these do not exist at this site The Plan states that the training records <br />shall be maintained on the Training Record Form in Appendix G; the facility is now using an online tracking system <br />The Spill Prevention. Control. and Countermeasure (SPCC) Plan most be amended when there is a change in the <br />facility design. construction, operation, or maintenance that materially affects its potential for a discharge. within 6 <br />months of the change, and implemented as soon as possible. not later than 6 months following preparation of the <br />amendment immediately make all necessary amendments to the SPCC Plan to accurately represent the procedures <br />and policies currently in place at the facility. <br />This is a minor violation <br />604 <br />CFR 112.7(a)(3) No facility diagram or didn't show location and contents of containers, transfer stations, and pipes. <br />The facility dlagrarn has not been updated since the reconstruction of the site conducted in summer of 2014. The <br />facility diagram did not include the drum storage In the outside hazardous waste storage area or the locations of piping <br />attached to the 10.000 gallon tanks The Spill Prevention. Control, and Countermeasure (SPCC) Plan shall include a <br />fac lity dingrant which must mark the location and contents of each fixed storage container and the storage area where <br />mobile or portable containers are located it must identify the location of and mark as "exempt" underground tanks It <br />must also Include all transfer stations and connecting pipes, including intra -facility gathering lines Immediately <br />update the facility diagram to include all of the required information Submit a legible copy of the updated facility <br />diagram to the EHD for review <br />This Is a Class II violation <br />Received by inspoctor: <br />(initial): STACY RIVERA. Senior RENS <br />Phone: <br />(209) 468-3440 <br />Date: <br />03120;2015 <br />Nagesoro <br />