My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PETERSEN
>
3663
>
2800 - Aboveground Petroleum Storage Program
>
PR0517463
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2019 11:41:08 AM
Creation date
10/10/2018 4:21:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0517463
PE
2832
FACILITY_ID
FA0010627
FACILITY_NAME
Penske Truck Leasing Co., LP
STREET_NUMBER
3663
STREET_NAME
PETERSEN
STREET_TYPE
Rd
City
Stockton
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
3663 Petersen Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County' r '--``' <br />Environmental Health Department <br />17 2015 <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 APR <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Aboveground Petroleum Storage Act Inspection Rep0l ','rl4nco�nTAAcNI' <br />Facility Name: <br />[Facility Address: <br />Date: <br />. Leash <br />F=ete,: <br />C', _ , 20 : _- <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR- Notice to Comply) <br />Iteral # <br />Remarks <br />r05 <br />CFR 112.7(a)(3) Plan failed to address facility layout, operations discharge prevention methods and containers. <br />The Plan include the drums of waste oil and owwater separator sludge in the hazardous waste storage area <br />The Plan did not discuss disposal of recovered materials The contact list did not include the San Joaquin County <br />Environmental Health Deparlment The Plan did not discuss the concrete containment area for piping located betweer, <br />the two 10,000 gallon diesel tanks. The following shall be addressed in the Spill Prevention, Control, and <br />Countermeasure (SPCC) Plan. <br />- type of oil in each fixed container and it's storage capacity For mobile or potable containers, the type of oil and <br />storage capacity for each container or an estimate of the potential number of mobile or portable containers. the types <br />of oil, and anticipated storage capacities <br />- discharge prevention measures Including procedures for routine handling of products <br />discharge or drainage controls such as secondary containment, equipment, and procedures for the control of a <br />discharge <br />countermeasures for discharge discovery. response, and cleanup <br />methods of disposal of recovered materials <br />contact list and phone numbers for the facility response coordinator. National Response Center, cleanup <br />contractors, and all appropriate Federal, State, and local agencies. <br />Immediately amend the SPCC Plan to include all required information <br />This Is a Class II violation <br />description of equipme failure or provide equivalence. <br />CFR 112.7(b) Plan failed to include a potential <br />Potential equipment failure and the ie5uitiny spill for uiuiiis ui wdstC CJh al,0uii,.tiui ,�, �i =:�: ,".:ge In the <br />area was not addressed in the Spill Prevention. Control, and Countermeasure (SPCC) Plan <br />hazardous waste storage <br />The SPCC Plan must include a prediction of the direction, rate of flow, and total quantity of oil which could be <br />discharged from the facility as a result of major equipment failure. Immediately amend the SPCC Plan to include ti,r, <br />information and submit a copy of the revision to the EHD, or provide equivalence as allowed by 40 CFR 112.7(a)(2) <br />This Is a minor vin!ntion <br />13 <br />CFR 112.8(c)(6) Failed to perform scheduled tank tests and inspections by appropriately qualified personnel. <br />::,.j .�y .,,sting is to be conducted every 20 years for the 10,000 gallon diesel tanks, with <br />the first test to take place after the Plan was written and implemented. No integrity testing records were provided at <br />the time of inspection. Each aboveground container shall be tested and inspected for integrity on a regular schedule <br />and whenever repairs are made. The qualifications of personnel performing tests and inspections. frequency and typ, <br />of testing and inspections that take Into account container size, configuration. and design shall be determined in <br />accordance with industry standards Examples of these integrity tests include. but are not limited to visual <br />inspection. hydrostatic testing, radiographic testing. ultrasonic testing, acoustic emissions testing, or other system: <br />testing. Comparison records and other records of inspections and tests must be maintained on <br />of non-destructive <br />site Immediately conduct the necessary testing and submit a copy of the test results to the EHD, or provide <br />equivalence as allowed by CFR 112-7(a)(2). <br />his is a repeat violation, Class II <br />Received by <br />(initial): <br />Inspector: <br />STACY RIVERA. Senior REH` _ <br />Phone: <br />2091 468-3440 <br />Date: <br />03/20/2015 <br />Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.