Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.s gov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A TEICHERT & SON INC` 1 120 FRANK WEST CIR, STOCKTON September 11. 2015 <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 723 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping ❑V ❑R ❑COS <br /> 724 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V ❑R ❑COS <br /> 725 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves, piping, and appurtenances ❑V ❑R ❑COS <br /> 727 CFR 112.8(d)(4) Failed to conduct integrity and leak test on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 728 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V ❑R ❑COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 603 CFR 112.7(a)(2) Plan failed to discuss equivalent environmental protection, if applicable. <br /> The Spill Prevention, Control, and Countermeasure (SPCC) failed to discuss alternative environmental protection <br /> requirements. The SPCC Plan states that visual inspections will be used in lieu of integrity testing, but does not state <br /> the reasons for nonconformance. If the SPCC Plan does not conform to the applicable requirements, the reasons for <br /> nonconformance must stated and the alternate methods to achieve equivalent environmental protection must be <br /> described in detail in the Plan. Immediately amend the SPCC Plan to include a discussion of equivalent <br /> environmental protection. <br /> This is a Class II violation. <br /> >Og CFR 112.7(c) Failed to provide secondary containment, diversionary structures, or equipment to prevent discharge. <br /> Oily staining was observed on the west side wall of the oil tanks, on the ground around the bottom of the tanks, and <br /> on the shelving near the tanks. A facility shall provide appropriate containment and/or diversionary structures or <br /> equipment to prevent a discharge. The entire containment system, including walls and floor, must be capable of <br /> containing oil and must be constructed so that any discharge from a primary containment system will not escape the <br /> containment system before cleanup occurs. Immediately provide adequate secondary containment for all aboveground <br /> petroleum storage containers larger than 55 gallons. <br /> This is a Class II violation. <br /> Received by Inspector: Phone: Date: <br /> (initial): STACY RIVERA, Senior REHS (209)468-3440 09/11/2015 <br /> Page 3 of 4 <br />