My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
166
>
2800 - Aboveground Petroleum Storage Program
>
PR0515523
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2019 11:09:52 AM
Creation date
10/11/2018 3:54:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0515523
PE
2832
FACILITY_ID
FA0006289
FACILITY_NAME
VALLEY PACIFIC PETROLEUM SERVICES
STREET_NUMBER
166
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342003
CURRENT_STATUS
01
SITE_LOCATION
166 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
259
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONDOR EARTH <br /> 188 Frank West Circle,Suite I <br /> ' Stockton,CA 95206 <br /> 209.234.0518 <br /> Fax 209.234.0538 <br /> CONDORwww.condarearth.com <br /> Condor Project 7167C2 <br /> October 1, 2018 <br /> Will Harp,Terminal Manager Northern Region <br /> Valley Pacific Petroleum Services, Inc. <br /> 166 Frank West Circle <br /> Stockton, CA 95206 <br /> Subject: Formal External Inspection of an 10,000-gallon Aboveground Storage Tank(AST-7), <br /> Valley Pacific Petroleum Services—Stockton Facility, Stockton, San Joaquin County, <br /> California <br /> Dear Mr. Harp: <br /> Condor Earth (Condor) inspected the 10,000-gallon Aboveground Storage Tank (AST) at the Stockton <br /> Facility(Facility)located at 166 Frank West Circle, Stockton,California. The AST(AST-7)was inspected <br /> on February 15,2017,by James Montgomery,AST Inspector No.AST-133458,and Jordan Johnson,AST <br /> Inspector No. AST-T10388. Condor performed the inspection in general conformance with Steel Tank <br /> Institute(STI) Standard SP001 5th Edition- September 2011 Formal External Inspection(FEI). <br /> The subject AST-7 is a double-wall steel tank with an integral secondary spill containment interstice. The <br /> tank's configuration is consistent with a Category I AST and has the following inspection schedule: <br /> Tank Category Monthly Annual Formal Formal <br /> I,II,or III inspections* Inspections* External Internal Leak Test <br /> Inspection** Inspection** (Years) <br /> (volume-gallons) (Y/N) (�'�) (Years) (Years) <br /> I(10,000 al) j Y j Y j 20 1 - - <br /> *Completed by owner's inspector. **Completed by Certified Inspector. <br /> Visual Observations <br /> • The subject tank,AST-7 has an Underwriters Laboratory(UL)AST identification label. <br /> • The tank was fabricated manufactured by Brown - Minneapolis Tank. The fabrication date was <br /> undetermined. <br /> • The exterior wall of the tank and ancillary piping was inspected and appeared to be in good <br /> condition. <br /> • Condor did not locate a high-level liquid alarm which would minimize overfill and protect the <br /> structural integrity of the tank;however,the tank was equipped with an adequate liquid level gauge. <br /> • Visual observations of the tank's exterior shell and roof showed no signs of pitting. <br />
The URL can be used to link to this page
Your browser does not support the video tag.